m2ABQ——对基于改良算法的骨质疏松性椎体骨折定性分类的改进建议
本研究旨在为机器学习目的改进一种规则清晰的骨质疏松性椎体骨折分类方法,回顾性获取65岁及以上患者胸腰椎X线片数据库,由5名评估者使用m2ABQ系统独立分类,结果显示评估者间一致性中等,且随培训提高,结论认为未来需与现有研究比较并进一步开发其机器学习用途。
要点
- m2ABQ系统将椎体分为五类,用于骨质疏松性椎体骨折分类。
- 骨折存在与否的Fleiss kappa从0.62(0.56-0.68)提高到0.70(0.65-0.75)。
- 整个m2ABQ量表的Fleiss kappa从0.29(0.25-0.33)提高到0.54(0.51-0.58)。
核心结论
- m2ABQ系统在分类骨质疏松性椎体骨折方面显示出中等的评估者间一致性和实际可行性。
- 未来需要开展研究将该方法与现有研究进行比较,并进一步开发其在机器学习中的用途。
研究设计与样本
- 回顾性从临床机构放射学记录中,使用自然语言处理获取65岁及以上患者胸腰椎X线片的骨折富集数据库。
- 开发了一套称为m2ABQ的规则和改进措施,将椎体分为五个类别。
- 由5名评估者使用m2ABQ系统独立分类每个椎体,每轮标注后举行共识会议讨论并最终确定共识标注,此过程进一步改进和开发了规则。
主要发现
- 每轮标注显示,骨折存在与不存在的Fleiss kappa从0.62(0.56-0.68)提高到0.70(0.65-0.75)。
- 整个m2ABQ量表的Fleiss kappa从0.29(0.25-0.33)提高到0.54(0.51-0.58)。
局限性
- 未来需要开展研究将该方法与现有研究进行比较,并进一步开发其在机器学习中的用途。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Currently, there is no reproducible, widely accepted gold standard to classify osteoporotic vertebral body fractures (OVFs). The purpose of this study is to refine a method with clear rules to classify OVFs for machine learning purposes. The method was found to have moderate interobserver agreement that improved with training. INTRODUCTION: The current methods to classify osteoporotic vertebral body fractures are considered ambiguous; there is no reproducible, accepted gold standard. The purpose of this study is to refine classification methodology by introducing clear, unambiguous rules and a refined flowchart to allow consistent classification of osteoporotic vertebral body fractures. METHODS: We developed a set of rules and refinements that we called m2ABQ to classify vertebrae into five categories. A fracture-enriched database of thoracic and lumbar spine radiographs of patients 65 years of age and older was retrospectively obtained from clinical institutional radiology records using natural language processing. Five raters independently classified each vertebral body using the m2ABQ system. After each annotation round, consensus sessions that included all raters were held to discuss and finalize a consensus annotation for each vertebral body where individual raters' evaluations differed. This process led to further refinement and development of the rules. RESULTS: Each annotation round showed increase in Fleiss kappa both for presence vs absence of fracture 0.62 (0.56-0.68) to 0.70 (0.65-0.75), as well as for the whole m2ABQ scale 0.29 (0.25-0.33) to 0.54 (0.51-0.58). CONCLUSION: The m2ABQ system demonstrates moderate interobserver agreement and practical feasibility for classifying osteoporotic vertebral body fractures. Future studies to compare the method to existing studies are warranted, as well as further development of its use in machine learning purposes.
引用
- Aaltonen HL, O'Reilly MK, Linnau KF, et al. m2ABQ-a proposed refinement of the modified algorithm-based qualitative classification of osteoporotic vertebral fractures. Osteoporos Int. 2022. PMID: 36336755. doi:10.1007/s00198-022-06546-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。