后胫骨平台坡度升高与翻修前交叉韧带移植物失败的匹配队列分析关联
这项病例对照研究(证据等级3)将38例翻修ACL移植物失败患者与38例匹配的翻修ACL重建成功对照比较,发现失败组内、外侧PTS在X线和MRI上均显著更高。影像学内侧PTS≥14°预测翻修移植物失败的风险最高(OR 18.71)。
要点
- 翻修ACL移植物失败组X线内侧PTS 13.2°±2.9°高于对照10.3°±2.9°(P<.001);外侧12.9°±3.0°高于9.8°±2.8°(P<.001)。
- MRI内侧PTS 7.2°±3.1°高于对照4.8°±2.9°(P<.001);外侧8.4°±3.1°高于5.9°±3.0°(P<.001)。
- 影像学内侧PTS≥14°与翻修ACL移植物失败风险升高相关:OR 18.71(95%CI 2.0-174.9;P=.01),敏感度50%,特异度92.1%。
核心结论
- 后胫骨平台坡度升高是翻修前交叉韧带移植物失败的显著危险因素。
- 影像学内侧PTS≥14°的患者翻修ACL失败风险增加18.7倍。
研究设计与样本
- 病例对照研究,证据等级3。
- 从翻修ACL数据库识别38例翻修ACL移植物失败患者,按年龄、性别和移植物类型1:1匹配38例无移植物失败证据的翻修ACL重建对照,对照最低随访2年。
- 通过患肢膝关节侧位X线和MRI测量内、外侧PTS,比较两组人口学、手术特征和PTS,用受试者工作特征曲线确定预测翻修ACL移植物失败风险升高的最佳截断值,用条件多变量logistic回归评估PTS截断值作为预测因子的相对贡献。
主要发现
- X线平均PTS失败组显著高于对照组:内侧13.2°±2.9° vs 10.3°±2.9°(P<.001),外侧12.9°±3.0° vs 9.8°±2.8°(P<.001)。
- MRI平均PTS失败组显著高于对照组:内侧7.2°±3.1° vs 4.8°±2.9°(P<.001),外侧8.4°±3.1° vs 5.9°±3.0°(P<.001)。
- 影像学内侧PTS≥14°预测翻修ACL移植物失败风险升高最高,敏感度50%,特异度92.1%(OR 18.71;95%CI 2.0-174.9;P=.01)。
关键数值与推荐
- 影像学内侧PTS≥14°:OR 18.71(95%CI 2.0-174.9;P=.01),敏感度50%,特异度92.1%。
- X线内侧PTS:失败组13.2°±2.9° vs 对照组10.3°±2.9°(P<.001)。
- X线外侧PTS:失败组12.9°±3.0° vs 对照组9.8°±2.8°(P<.001)。
- MRI内侧PTS:失败组7.2°±3.1° vs 对照组4.8°±2.9°(P<.001)。
- MRI外侧PTS:失败组8.4°±3.1° vs 对照组5.9°±3.0°(P<.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Elevated posterior tibial slope (PTS) has been identified as an important risk factor in anterior cruciate ligament (ACL) injuries and ACL graft failures. The cutoff value to recommend treatment with slope-reducing osteotomy remains unclear and is based on expert opinion and small case series. PURPOSE: (1) To determine whether there is a difference in PTS shown on lateral knee radiographs and magnetic resonance imaging (MRI) scans in a group of patients who experienced revision ACL graft failure versus a control group of patients who underwent successful revision ACL reconstruction, (2) to identify cutoff values of PTS measurements that predict risk of revision ACL graft failure, and (3) to examine whether there is a correlation between radiographic and MRI measurements of PTS. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: A total of 38 patients who experienced revision ACL graft failure were identified from a revision ACL database. These patients were matched 1:1 by age, sex, and graft type to a group of 38 control patients who underwent revision ACL reconstruction with no evidence of graft failure at a minimum 2 years of follow-up. Medial and lateral PTS were measured by lateral knee radiographs and MRI scans of the affected limb. Demographics, surgical characteristics, and PTS were compared between the groups. The optimal cutoff values of medial and lateral PTS per radiographs and MRI scans for predicting increased risk of revision ACL graft failure were determined by receiver operating characteristic curves. Conditional multivariable logistic regression was used to assess the relative contribution of PTS cutoff values as a predictor of revision graft failure. RESULTS: The mean PTS values in the failure group were significantly higher than those in the control group on radiographs (medial, 13.2°± 2.9° vs 10.3°± 2.9°; P < .001; lateral, 12.9°± 3.0° vs 9.8°± 2.8°; P < .001) and MRI scans (medial, 7.2°± 3.1° vs 4.8°± 2.9°; P < .001; lateral, 8.4 ± 3.1° vs 5.9 ± 3.0°; P < .001). A radiographic medial PTS ≥14° had the highest increased risk of revision ACL graft failure with sensitivity equal to 50% and specificity to 92.1% (odds ratio, 18.71; 95% CI, 2.0-174.9; P = .01). CONCLUSION: Elevated PTS was a significant risk factor for revision ACL graft failure. Patients with radiographic medial PTS ≥14° had 18.7-times increased risk of revision ACL failure.
引用
- Duerr RA, Ormseth B, DiBartola A, et al. Association of Elevated Posterior Tibial Slope With Revision Anterior Cruciate Ligament Graft Failure in a Matched Cohort Analysis. Am J Sports Med. 2022. PMID: 36412535. doi:10.1177/03635465221134806
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。