文献速递关节外科

50岁以下患者双侧植入骨水泥型与非骨水泥型全髋关节置换术至少30年结果

Minimum 30-Year Results of Bilaterally Implanted Cemented and Cementless Total Hip Arthroplasty in Patients Younger Than 50 Years.
PubMed 文献 · J Arthroplasty · 2022-11-19

本研究纳入106例50岁以下行双侧全髋关节置换术患者,一侧用骨水泥柄、另一侧用非骨水泥柄,平均随访31年。末次随访两组Harris髋关节评分相似(90分与91分),股骨柄长期固定效果优异,但两组髋臼组件因传统聚乙烯磨损和髋臼周围骨溶解而翻修率均较高。

要点

  • 骨水泥组与非骨水泥组末次随访Harris髋关节评分相似(90分与91分)。
  • 骨水泥组髋臼组件翻修46例(43%),非骨水泥组48例(45%)。
  • 两组股骨组件30.8年生存率相似(骨水泥组95% vs 非骨水泥组96%)。

核心结论

  • 骨水泥型或非骨水泥型股骨柄的长期固定效果优异。
  • 在混合型与完全非骨水泥型全髋关节置换术中,因传统聚乙烯磨损和髋臼周围骨溶解导致髋臼组件翻修率均较高。

研究设计与样本

  • 本研究纳入106例患者,每例一侧髋植入骨水泥柄、另一侧植入非骨水泥柄行双侧全髋关节置换术,其中男78例、女28例,平均年龄47岁(范围21-49岁),平均随访31年(范围30-32.5年)。

主要发现

  • 末次随访时两组平均Harris髋关节评分相似(骨水泥组90分 vs 非骨水泥组91分)。
  • 骨水泥组髋臼组件翻修46例(43%),非骨水泥组髋臼组件翻修48例(45%)。
  • 骨水泥组股骨组件翻修5例(5%),非骨水泥组股骨组件翻修4例(4%)。
  • 30.8年髋臼组件生存率两组相似(骨水泥组57% vs 非骨水泥组55%)。
  • 30.8年股骨组件生存率两组相似(骨水泥组95% vs 非骨水泥组96%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The rate of failure of cemented and cementless total hip arthroplasty (THA) in younger patients is higher than that in elderly patients. The purpose of this study is to document the long-term clinical results of THA with the so-called third-generation cementing and the results of second-generation cementless THA in patients <50 years of age. METHODS: This study included 106 patients who had had bilateral THA with a cemented stem in one hip and a cementless stem in the other. There were 78 men and 28 women. Their mean age was 47 years (range, 21-49). The average follow-up duration was 31 years (range, 30-32.5). RESULTS: There were similar mean Harris Hip Scores (90 versus 91 points) between the groups at the final follow-up. Forty-six acetabular components (43%) in the cemented group and 48 acetabular components (45%) in the cementless group were revised. Five femoral components (5%) in the cemented group and 4 femoral components (4%) in the cementless group were revised. Survivorship of the acetabular component at 30.8 years was similar in both groups (57% in the cemented group versus 55% in the cementless group). Survivorship of the femoral component at 30.8 years was also similar in both groups (95% in the cemented group versus 96% in the cementless group). CONCLUSION: Long-term fixation of the cemented or cementless femoral stem was outstanding. There was a high rate of the acetabular component revision due to conventional polyethylene wear and periacetabular osteolysis in both hybrid and fully cementless THA groups.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kim YH, Park JW, Jang YS, et al. Minimum 30-Year Results of Bilaterally Implanted Cemented and Cementless Total Hip Arthroplasty in Patients Younger Than 50 Years. J Arthroplasty. 2022. PMID: 36410630. doi:10.1016/j.arth.2022.11.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。