全髋关节置换术后股骨前倾角测量:三维双平面X线摄影与CT的对比验证研究
本研究纳入45例2016年2月至2020年2月间接受全髋关节置换术且术后同时行CT和EOS扫描的患者,比较三维双平面X线摄影(hipEOS)与CT测量股骨柄前倾角的一致性。结果显示两种方法测量的术后股骨柄前倾角均值无显著差异(p=0.862),强相关(r=0.95;p<0.001),平均配对差值为-0.09°(95%CI -1.09至0.91),仅3例(6.7%)差值>5°。作者认为三维EOS是测量术后股骨前倾角的可靠选择。
要点
- CT与三维双平面X线摄影测量的术后股骨柄前倾角均值无显著差异(p=0.862)。
- 两种方法测量值强相关(r=0.95;p<0.001),平均配对差值为-0.09°(95%CI -1.09至0.91)。
- 仅3例(6.7%)股骨柄测量差值>5°被认定为离群值。
核心结论
- 本研究支持使用低剂量双平面X线摄影进行全髋关节置换术后股骨柄前倾角的评估,其与CT显示高度相关性。
- 作者认为,鉴于三维EOS具有辐射剂量更低和检查时间更短的优点,它是测量术后股骨前倾角的可靠选择。
研究设计与样本
- 纳入45例于2016年2月至2020年2月间接受全髋关节置换术且术后同时行CT和EOS扫描的患者进行评价。
- 由一名接受过专科培训的肌骨放射科医生和一名放射科技师分别测量CT和三维EOS的股骨前倾角。
- 对每种影像学方法的测量值进行统计学显著性比较。
主要发现
- CT与三维hipEOS测量的术后股骨柄前倾角均值比较无显著差异(p=0.862)。
- 两种前倾角测量值强相关(r=0.95;p<0.001)。
- CT扫描与三维双平面X线摄影的术后股骨前倾角平均配对差值为-0.09°(95%CI -1.09至0.91)。
- 仅3例(6.7%)股骨柄测量差值>5°,被认定为离群值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods. METHODS: In this study, 45 patients who underwent THA between February 2016 and February 2020 and had both a postoperative CT and EOS scan were included for evaluation. A fellowship-trained musculoskeletal radiologist and radiological technician measured femoral version for CT and 3D EOS, respectively. Comparison of values for each imaging modality were assessed for statistical significance. RESULTS: Comparison of the mean postoperative femoral stem version measurements between CT and 3D hipEOS showed no significant difference (p = 0.862). In addition, the two version measurements were strongly correlated (r = 0.95; p < 0.001), and the mean paired difference in postoperative femoral version for CT scan and 3D biplanar radiography was -0.09° (95% confidence interval -1.09 to 0.91). Only three stem measurements (6.7%) were considered outliers with a > 5° difference. CONCLUSION: Our study supports the use of low-dose biplanar radiography for the postoperative assessment of femoral stem version after THA, demonstrating high correlation with CT. We found no significant difference for postoperative femoral version when comparing CT to 3D EOS. We believe 3D EOS is a reliable option to measure postoperative femoral version given its advantages of lower radiation dosage and shorter examination time.Cite this article: Bone Joint J 2022;104-B(11):1196-1201.
引用
- Anderson CG, Brilliant ZR, Jang SJ, et al. Validating the use of 3D biplanar radiography versus CT when measuring femoral anteversion after total hip arthroplasty : a comparative study. Bone Joint J. 2022. PMID: 36317354. doi:10.1302/0301-620X.104B11.BJJ-2022-0194.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。