文献速递运动医学关节外科

基于功能和影像学表现判断肩袖再撕裂后预后良好或不良的预后因素

Prognostic Factors Leading to Good or Poor Outcomes Based on Functional and Radiological Findings After a Rotator Cuff Retear.
PubMed 文献 · Am J Sports Med · 2022-10-27

纳入51例关节镜下肩袖修复术后1年磁共振成像确认再撕裂且随访至少24个月的患者,按是否达到临床结局指标的临床最小重要差值分为预后良好组36例与预后不良组15例。术后肩肱距离、冈下肌腱脂肪变性、再撕裂后侧与前侧矢状面范围及前后径撕裂大小变化与再撕裂后不良结局相关。前后径再撕裂大小增加和肩肱距离减小是与再撕裂后临床结局不良相关的影像学参数。

要点

  • 再撕裂后前后径撕裂大小增加和肩肱距离减小与临床结局不良相关。
  • 冈下肌腱脂肪变性及再撕裂后侧、前侧矢状面范围与不良预后相关。
  • 再撕裂后侧和前侧矢状面范围与肩袖缆受累相关。

核心结论

  • 前后径再撕裂大小增加和肩肱距离减小是与再撕裂后临床结局不良相关的影像学参数。
  • 再撕裂后侧和前侧矢状面范围、可能伴肩袖缆受累及冈下肌腱更严重脂肪变性的患者结局更差。

研究设计与样本

  • 病例对照研究,证据等级3级。
  • 共纳入51例关节镜下肩袖修复术后1年磁共振成像确认再撕裂且随访至少24个月的患者。
  • 按是否达到临床结局指标的临床最小重要差值分为预后良好组与预后不良组。

主要发现

  • 预后良好组36例,预后不良组15例。
  • 两组基线人口学和术前影像学参数无显著差异。
  • 预后不良组末次随访时活动度降低。
  • 两组术后前后径和后内侧径再撕裂大小均减小,但预后不良组再撕裂大小显著更大(均P < .05)。
  • 预后良好组肩肱距离增加(P < .001),预后不良组肩肱距离减小(P = .230)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A retear after rotator cuff repair is a common problem; however, there is little information related to the prognosis after a retear. In addition, some patients with retears have satisfactory outcomes, which raises the question of whether a retear leads to a poor prognosis. PURPOSE: To identify radiological factors that influence the prognosis after a retear. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: A total of 51 patients with retears confirmed by magnetic resonance imaging at 1 year after arthroscopic rotator cuff repair with a minimum follow-up of 24 months were enrolled in this study. Patients were divided into 2 groups according to whether they achieved the minimal clinically important difference for clinical outcome measures. Range of motion and radiological variables, including preoperative and postoperative anteroposterior (AP) and mediolateral (ML) tear sizes, sagittal extent of the retear, acromiohumeral distance (AHD), and degree of fatty degeneration, were analyzed using magnetic resonance imaging. RESULTS: Overall, 36 patients were allocated to the good prognosis (GP) group and 15 to the poor prognosis (PP) group. The 2 groups had no significant differences in baseline demographics and preoperative radiological parameters. Postoperative range of motion was decreased in the PP group at the last follow-up. The AP and ML retear sizes decreased in both groups after arthroscopic rotator cuff repair, but the retear size was significantly larger in the PP group (both P < .05). The AHD increased in the GP group (P < .001) but decreased in the PP group (P = .230) postoperatively. Logistic regression analysis revealed that postoperative AHD (P = .003), fatty degeneration of the infraspinatus tendon (P = .001), posterior (P = .007) and anterior (P = .025) sagittal extent of the retear, and change in the AP tear size (P = .017) were related to poor outcomes after a retear. However, change in the ML tear size (P = .105) and middle sagittal extent of the retear (P = .878) were not related to a poor prognosis. Also, further analysis showed that posterior (P = .006) and anterior (P = .003) sagittal extent of the retear were related to rotator cable involvement. CONCLUSION: An increased AP retear size and decreased AHD were radiological parameters that were associated with poor clinical outcomes after a retear. In particular, patients who had posterior and anterior sagittal extent of the retear, possibly with rotator cable involvement and more severe fatty degeneration of the infraspinatus tendon, showed worse outcomes.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Kim G, Kim S, Lee Y, et al. Prognostic Factors Leading to Good or Poor Outcomes Based on Functional and Radiological Findings After a Rotator Cuff Retear. Am J Sports Med. 2022. PMID: 36300545. doi:10.1177/03635465221128232

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。