过高的修复张力会降低肩袖内的微血管血流
研究对30例全层肩袖撕裂患者,在0、10、20、30 N四档张力下同步测量肩袖微血管血流。0 N与10 N间血流无显著差异(P=.716),但0 N与20 N、0 N与30 N间血流显著下降(P=.002、P<.001)。结论认为肩袖修复中≥10 N的张力会显著降低肩袖内微血管血流。
要点
- 0 N与10 N张力下肩袖微血管血流无显著差异(P=.716)。
- 0 N与20 N张力下血流显著下降(P=.002),0 N与30 N张力下亦显著下降(P<.001)。
- 作者结论认为修复张力≥10 N会显著降低肩袖内微血管血流。
核心结论
- 作者结论认为,肩袖修复中≥10 N的张力会显著降低肩袖内微血管血流。
- 作者认为这些数据有助于确定肩袖修复中的最佳修复张力。
研究设计与样本
- 受控实验室研究,纳入30例全层肩袖撕裂患者。
- 用数字张力计与接触式激光多普勒血流计同步测量修复张力与肩袖微血管血流。
- 在0、10、20、30 N四档张力下,于肩袖5个点测量微血管血流。
- 采用线性混合效应模型统计分析张力对肩袖微血管血流的影响。
主要发现
- 0 N张力下肩袖微血管血流均值为3.51 mL/min/100 g(95%CI 3.0-4.0),10 N下均值为3.74 mL/min/100 g(95%CI 3.2-4.3),两者差异无统计学意义(P=.716)。
- 0 N与20 N张力下肩袖微血管血流(均值2.84 mL/min/100 g,95%CI 2.3-3.4)差异有统计学意义(P=.002)。
- 0 N与30 N张力下肩袖微血管血流(均值2.45 mL/min/100 g,95%CI 1.9-3.0)差异有统计学意义(P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Repair tension and microvascular blood flow within the rotator cuff has a critical impact on tendon healing after rotator cuff repair. However, the relationship between repair tension and microvascular blood flow within the rotator cuff remains unclear. PURPOSE/HYPOTHESIS: The purpose of this study was to determine how much tension adversely affects microvascular blood flow within the rotator cuff. The hypothesis was that as the repair tension increases, the microvascular blood flow within the rotator cuff decreases. STUDY DESIGN: Controlled laboratory study. METHODS: Repair tension and microvascular blood flow within the rotator cuff of 30 patients with full-thickness rotator cuff tears were simultaneously measured using a digital tension meter and a contact-type laser Doppler flowmeter, respectively. Microvascular blood flow was measured under 4 levels of tension (0, 10, 20, and 30 N) at 5 points on the rotator cuff. The obtained values were statistically analyzed by a linear mixed-effects model to clarify the effect of tension on microvascular blood flow within the rotator cuff. RESULTS: There was no statistically significant difference in microvascular blood flow (mL/min/100 g) within the rotator cuff between 0 N (mean, 3.51; 95% CI, 3.0-4.0) and 10 N (mean, 3.74; 95% CI, 3.2-4.3) of tension (P = .716). However, there were statistically significant differences in microvascular blood flow within the rotator cuff between 0 and 20 N of tension (mean, 2.84; 95% CI, 2.3-3.4) (P = .002) and between 0 and 30 N of tension (mean, 2.45; 95% CI, 1.9-3.0) (P < .001). CONCLUSION/CLINICAL RELEVANCE: Our findings indicate that tension of ≥10 N during rotator cuff repair significantly decreases the microvascular blood flow within the rotator cuff. These data will contribute to determining the optimal repair tension during rotator cuff repair.
引用
- Miyake S, Izaki T, Arashiro Y, et al. Excessively High Repair Tension Decreases Microvascular Blood Flow Within the Rotator Cuff. Am J Sports Med. 2022. PMID: 36263917. doi:10.1177/03635465221125939
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。