两种现代全腕关节置换术的随机对照试验:非类风湿腕关节两年随访功能改善且假体稳定,但并发症率高
该随机对照试验纳入40例非类风湿腕关节炎患者,比较ReMotion与Motec两种全腕关节置换术的两年结局。两组患者评分和疼痛均显著改善且相似,Motec组金属离子水平更高,几乎三分之一患者因并发症需再手术。作者认为该手术应限于开展前瞻性分析的专科中心。
要点
- 两组患者评分和疼痛均显著改善且相似,但仅Motec组腕关节活动度显著改善,仅ReMotion组前臂旋转显著改善。
- Motec金属对金属组的钴和铬血离子水平显著高于ReMotion金属对聚乙烯组。
- 几乎三分之一患者因并发症需再手术,两枚ReMotion假体因腕骨组件松动翻修为Motec,三例Motec金属对金属关节因疼痛性滑膜炎翻修为金属对聚醚醚酮。
核心结论
- 两种假体在短期随访中提供匹配的功能且稳定,但并发症率高。
- 作者认为该手术应限于开展前瞻性分析的专科中心,直至其作用明确。
研究设计与样本
- 随机对照试验,共纳入40例非类风湿腕关节炎患者,比较ReMotion与Motec两种全腕关节置换术。
- 比较患者评分与功能结局、影像学改变、血金属离子水平、基于模型放射立体分析(RSA)测量的迁移、双能X线吸收测定(DXA)测量的骨密度、并发症、松动及两年翻修率。
主要发现
- 两组患者腕手评价量表(PRWHE)评分、上肢功能障碍问卷简版(QuickDASH)评分和疼痛均相似且显著改善。
- 仅Motec组腕关节活动度显著改善,仅ReMotion组前臂旋转显著改善。
- 金属对金属(MoM)Motec组的钴(Co)和铬(Cr)血离子水平显著高于金属对聚乙烯(MoP)ReMotion组。
- ReMotion腕骨组件和桡骨组件的平均总平移分别为0.65 mm(95%CI 0.26至1.12)和0.27 mm(95%CI 0.14至0.47),Motec掌骨组件和桡骨组件分别为0.32 mm(95%CI 0.22至0.45)和0.26 mm(95%CI 0.20至0.34)。
- 除背侧和掌侧倾斜在ReMotion桡骨组件显著高于Motec组件外,绝对迁移无显著差异;桡骨组件周围骨密度从未恢复至基线。
关键数值与推荐
- 几乎三分之一患者因并发症需再手术。
- 两枚ReMotion假体因腕骨组件松动翻修为Motec全腕关节置换。
- 三例Motec金属对金属关节因疼痛性滑膜炎翻修为金属对聚醚醚酮。
临床怎么用
- 作者认为该手术应限于开展前瞻性分析的专科中心,直至其作用明确。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. METHODS: A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared. RESULTS: Patient-Rated Wrist and Hand Evaluation (PRWHE) scores, abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire scores, and pain improved similarly and significantly in both groups. Wrist motion improved significantly in the Motec group only, and forearm rotation in the ReMotion group only. Cobalt (Co) and chromium (Cr) blood ion levels were significantly higher in the metal-on-metal (MoM) Motec group than in the metal-on-polyethylene (MoP) ReMotion group. Mean total translation was 0.65 mm (95% confidence interval (CI) 0.26 to 1.12) and 0.27 mm (95% CI 0.14 to 0.47) for the ReMotion carpal and radial components, and 0.32 mm (95% CI 0.22 to 0.45) and 0.26 mm (95% CI 0.20 to 0.34) for the Motec metacarpal and radial components, respectively. Apart from dorsal and volar tilts, which were significantly higher for the radial ReMotion than for the Motec component, no significant differences in absolute migration occurred. BMD around the radial components never returned to baseline. Almost one-third of patients required reoperation due to complications. Two ReMotion implants were revised to Motec TWAs due to carpal component loosening, and three Motec MoM articulations were revised to metal-on-polyether ether ketone due to painful synovitis. CONCLUSION: Both implants provided matched function and were stable at short-term follow-up, but with a high complication rate. This procedure should be restricted to specialist centres undertaking prospective analysis until its role is clarified.Cite this article: Bone Joint J 2022;104-B(10):1132-1141.
引用
- Holm-Glad T, Røkkum M, Röhrl SM, et al. A randomized controlled trial comparing two modern total wrist arthroplasties : improved function with stable implants, but high complication rates in non-rheumatoid wrists at two years. Bone Joint J. 2022. PMID: 36177637. doi:10.1302/0301-620X.104B10.BJJ-2022-0201.R2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。