文献速递关节外科创伤骨科

Dorr分型与股骨固定方式对急性股骨颈骨折全髋关节置换术后结局的影响:一项多中心研究

The Influence of Dorr Type and Femoral Fixation on Outcomes Following Total Hip Arthroplasty for Acute Femoral Neck Fractures: A Multicenter Study.
PubMed 文献 · J Arthroplasty · 2022-10-22

这项多中心回顾性研究分析了2006至2020年间三家大型学术机构709例因股骨颈骨折行全髋关节置换的病例(骨水泥固定199例,非骨水泥固定510例),发现非骨水泥股骨柄的全因无菌性股骨翻修率(5.1% vs 0.5%,P=0.002)和假体周围股骨骨折率(4.3% vs 0%,P=0.001)均更高。非骨水泥植入物下Dorr A、B、C型的骨折率分别为2.3%、3.7%和15.9%(P<.001)。

要点

  • 非骨水泥股骨柄的全因无菌性股骨翻修率(5.1% vs 0.5%,P=0.002)和假体周围股骨骨折率(4.3% vs 0%,P=0.001)均高于骨水泥股骨柄。
  • 非骨水泥植入物下Dorr A、B、C型的假体周围骨折率分别为2.3%、3.7%和15.9%(P<.001)。
  • 逻辑回归分析证实非骨水泥股骨柄(P=0.02)和Dorr C型骨(P=0.001)与假体周围骨折相关;带领植入物和预防性钢缆未起到保护作用。

核心结论

  • 因股骨颈骨折行全髋关节置换时,非骨水泥股骨柄的全因无菌性股骨翻修率更高,具体为假体周围骨折。
  • Dorr C型骨尤其易发生假体周围骨折,骨折率惊人地高。
  • 所有骨折均发生在非骨水泥病例中,提示骨水泥股骨柄可能减少此并发症。

研究设计与样本

  • 多中心回顾性研究,纳入2006年至2020年间三家大型学术机构因股骨颈骨折行全髋关节置换的709例病例(骨水泥固定199例,非骨水泥固定510例)。
  • 回顾了人口学特征、围手术期特征和X线片,采用Kaplan-Meier法生成多种结局的生存曲线,并进行单变量和多变量分析,以P≤.05为显著性。

主要发现

  • 非骨水泥股骨柄的全因无菌性股骨翻修率为5.1%,骨水泥股骨柄为0.5%(P=0.002)。
  • 非骨水泥股骨柄的假体周围股骨骨折率为4.3%,骨水泥股骨柄为0%(P=0.001)。
  • 非骨水泥植入物下,Dorr A、B、C型的假体周围骨折率分别为2.3%、3.7%和15.9%(P<.001)。
  • 逻辑回归分析证实非骨水泥股骨柄(P=0.02)和Dorr C型骨(P=0.001)与假体周围骨折相关;带领植入物和预防性钢缆未起到保护作用。
  • 两组在脱位率、感染性翻修率或死亡率方面无差异。

关键数值与推荐

  • 非骨水泥股骨柄的全因无菌性股骨翻修率为5.1%,骨水泥股骨柄为0.5%(P=0.002)。
  • 非骨水泥股骨柄的假体周围股骨骨折率为4.3%,骨水泥股骨柄为0%(P=0.001)。
  • 非骨水泥植入物下,Dorr A、B、C型的假体周围骨折率分别为2.3%、3.7%和15.9%(P<.001)。
  • 逻辑回归分析显示非骨水泥股骨柄(P=0.02)和Dorr C型骨(P=0.001)与假体周围骨折相关。
  • 带领植入物和预防性钢缆未起到保护作用。

临床怎么用

  • 美国骨科医师学会(American Academy of Orthopaedic Surgeons)指南报告,对髋部骨折行股骨柄骨水泥固定有中等证据,主要来自半髋关节置换文献。
  • 作者认为,所有骨折均发生在非骨水泥病例中,提示骨水泥股骨柄可能减少此并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The American Academy of Orthopaedic Surgeons guidelines report moderate evidence for cementing femoral stems for hip fractures, mainly derived from hemiarthroplasty literature. This is the first large, nonregistry study examining the influence of femoral fixation, implant type, patient characteristics, and radiographic factors on outcomes after total hip arthroplasty (THA) for acute femoral neck fractures. METHODS: A multicenter retrospective study was performed of 709 THA cases (199 cemented, 510 cementless) for femoral neck fractures from 2006 to 2020 at three large academic institutions. Demographics, perioperative characteristics, and radiographs were reviewed. Kaplan-Meier survivorship curves were generated for multiple outcomes. Univariate and multivariate analyses were performed with P ≤ .05 denoting significance. RESULTS: Cementless stems had a higher all-cause aseptic femoral revision rate (5.1 versus 0.5%, P = .002) and periprosthetic femoral fracture rate (4.3 versus 0%, P = .001). Each successive Dorr type had a higher fracture rate with cementless implants: 2.3%, 3.7%, and 15.9% in Dorr A, B, and C, respectively (P < .001). Logistic regression analyses confirmed that cementless stems (P = .02) and Dorr C bone (P = .001) are associated with periprosthetic fractures; collared implants and prophylactic cables did not protect against fractures. There was no difference in rates of dislocation, septic revision, or mortality between groups. CONCLUSION: Cementless stems during THA for femoral neck fractures have a higher aseptic femoral revision rate, specifically for periprosthetic fractures. Dorr C bone was particularly prone with an alarmingly high fracture rate. All fractures occurred in cementless cases, suggesting that cemented stems may minimize this complication. LEVEL OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kheir MM, Dilley JE, Speybroeck J, et al. The Influence of Dorr Type and Femoral Fixation on Outcomes Following Total Hip Arthroplasty for Acute Femoral Neck Fractures: A Multicenter Study. J Arthroplasty. 2022. PMID: 36283515. doi:10.1016/j.arth.2022.10.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。