文献速递关节外科创伤骨科

牛津单髁膝关节置换术胫骨部件内翻放置可降低术后胫骨骨折风险

Varus placement of the tibial component of Oxford unicompartmental knee arthroplasty decreases the risk of postoperative tibial fracture.
PubMed 文献 · Bone Joint J · 2022-01-01

该回顾性研究纳入255例患者共305膝行无骨水泥胫骨部件牛津活动平台单髁膝关节置换术,比较传统截骨组与轻度内翻截骨组的胫骨平台骨折率及龙骨-皮质距离。内翻组术后胫骨骨折率显著低于传统组(1.1% vs 6.9%,p=0.029),且内翻组后侧龙骨-皮质距离显著更长。结论认为轻度内翻放置胫骨部件时龙骨与后侧胫骨皮质距离更长,似乎可降低术后胫骨骨折风险。

要点

  • 传统组术后胫骨内侧平台骨折15例(15膝),内翻组仅1例(1膝),差异显著(6.9% vs 1.1%,p=0.029)。
  • 内翻组后侧龙骨-皮质距离均值6.1 mm(SD 2.1)显著长于传统组5.0 mm(SD 1.7)(p=0.002)。
  • 轻度内翻放置胫骨部件似乎可降低牛津单髁术后胫骨平台骨折风险。

核心结论

  • 在牛津活动平台单髁膝关节置换术中,胫骨部件轻度内翻对线的患者龙骨与后侧胫骨皮质距离更长,似乎可降低术后胫骨骨折风险。

研究设计与样本

  • 回顾性研究,纳入255例患者共305膝行无骨水泥胫骨部件的牛津活动平台单髁膝关节置换术,其中52例男性、203例女性,平均年龄73.1岁(范围47至91岁),平均随访1.9年(范围1.0至2.0年)。
  • 传统组187例患者共217膝,胫骨截骨垂直于胫骨轴线;内翻组68例患者共88膝,使用新截骨导板行轻度内翻截骨。
  • 术后1周行3D CT评估前侧和后侧龙骨-皮质距离及骨折线起点,比较两组龙骨-皮质距离和骨折率。

主要发现

  • 传统组术后发生胫骨内侧平台骨折15例(15膝),内翻组仅1例(1膝),差异显著(6.9% vs 1.1%;p=0.029)。
  • 传统组后侧龙骨-皮质距离均值5.0 mm(SD 1.7),内翻组均值6.1 mm(SD 2.1),传统组显著短于内翻组(p=0.002)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. METHODS: This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide. Anterior and posterior KCDs and the origins of fracture lines were assessed using 3D CT scans one week postoperatively. The KCDs and rate of fracture were compared between the two groups. RESULTS: Medial tibial fractures occurred after surgery in 15 patients (15 OUKAs) in the conventional group, but only one patient (one OUKA) had a tibial fracture after surgery in the varus group. This difference was significant (6.9% vs 1.1%; p = 0.029). The mean posterior KCD was significantly shorter in the conventional group (5.0 mm (SD 1.7)) than in the varus group (6.1 mm (SD 2.1); p = 0.002). CONCLUSION: In OUKA, the distance between the keel and posterior tibial cortex was longer in our patients with slight varus alignment of the tibial component, which seems to decrease the risk of postoperative tibial fracture.Cite this article: Bone Joint J 2022;104-B(10):1118-1125.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Suda Y, Hiranaka T, Kamenaga T, et al. Varus placement of the tibial component of Oxford unicompartmental knee arthroplasty decreases the risk of postoperative tibial fracture. Bone Joint J. 2022. PMID: 36177640. doi:10.1302/0301-620X.104B10.BJJ-2021-1508.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。