文献速递小儿骨科

超声限制性影像方案用于Pavlik吊带监测(TULIPPS)在发育性髋关节发育不良中的随机对照试验

Testing of an Ultrasound-Limited Imaging Protocol for Pavlik harness Supervision (TULIPPS) in developmental dysplasia of the hip: a randomized controlled trial.
PubMed 文献 · Bone Joint J · 2022-01-01

该单中心非劣效性随机对照试验纳入100例6个月以下发育性髋关节发育不良婴儿,比较标准超声监测方案与限制频率超声方案。结果显示两组在治疗结束时α角和随访时髋臼指数无显著差异,限制频率组稳定后超声使用减少60%,支持在髋关节复位并居中后减少超声评估频率。

要点

  • 限制频率超声组与标准组在治疗结束时α角及随访时髋臼指数无显著差异。
  • 所有髋关节治疗结束时股骨头覆盖率>50%,随访时IHDI分级均为1级。
  • 限制频率组在稳定后超声使用减少60%,支持减少超声评估频率。

核心结论

  • 研究支持在Pavlik吊带治疗发育性髋关节发育不良中,一旦髋关节复位并居中,可减少超声评估频率。

研究设计与样本

  • 单中心非劣效性随机对照试验,纳入100例6个月以下婴儿,随机分配至标准超声监测方案组(每次门诊随访均行超声)或限制频率超声方案组(仅在治疗结束时行超声)。

主要发现

  • 治疗结束时右侧平均α角标准组70.0°(SD 3.2°)vs 限制组68.7°(SD 2.9°),p=0.033;左侧标准组69.0°(SD 3.5°)vs 限制组68.1°(SD 3.3°),p=0.128。
  • 随访时右侧平均髋臼指数标准组23.1°(SD 4.3°)vs 限制组22.0°(SD 4.1°),p=0.129;左侧标准组23.3°(SD 4.2°)vs 限制组22.8°(SD 3.9°),p=0.284。
  • 所有髋关节治疗结束时股骨头覆盖率>50%,随访时IHDI分级均为1级。
  • 限制频率组在稳定后超声使用减少60%。

关键数值与推荐

  • 标准方案组42例完成,限制方案组40例完成。
  • 治疗结束时右侧α角两组p=0.033,左侧p=0.128;随访时右侧髋臼指数p=0.129,左侧p=0.284。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. METHODS: This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared based on α angle and femoral head coverage at the end of PH treatment, acetabular indices, and International Hip Dysplasia Institute (IHDI) grade on one-year follow-up radiographs. RESULTS: Overall, 100 patients were included; 42 patients completed the standard protocol (SP) and 40 completed the limited protocol (LP). There was no significant difference in mean right α angle at the end of treatment (SP 70.0° (SD 3.2°) ; LP 68.7° (SD 2.9°); p = 0.033), nor on the left (SP 69.0° (SD 3.5°); LP 68.1° (SD 3.3°); p = 0.128). There was no significant difference in mean right acetabular index at follow-up (SP 23.1° (SD 4.3°); LP 22.0° (SD 4.1°); p = 0.129), nor on the left (SP 23.3° (SD 4.2°); LP 22.8° (SD 3.9°); p = 0.284). All hips had femoral head coverage of > 50% at end of treatment, and all were IHDI grade 1 at follow-up. In addition, the LP group underwent a 60% reduction in US use once stable. CONCLUSION: Our study supports reducing the frequency of US assessment during PH treatment of DDH once a hip is reduced and centred.Cite this article: Bone Joint J 2022;104-B(9):1081-1088.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Behman AL, Bradley CS, Maddock CL, et al. Testing of an Ultrasound-Limited Imaging Protocol for Pavlik harness Supervision (TULIPPS) in developmental dysplasia of the hip: a randomized controlled trial. Bone Joint J. 2022. PMID: 36047018. doi:10.1302/0301-620X.104B9.BJJ-2022-0350.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。