股骨偏心距减小与全髋关节置换术后功能结局较差相关
该研究对414例初次全髋关节置换术患者进行回顾性分析,随访至少12个月,比较术后影像学偏心距与对侧天然髋关节。回归分析显示偏心距减小超过20 mm与WOMAC疼痛(P=0.005)和活动(P=0.015)评分较差相关,而偏心距减小不超过20 mm及偏心距增大与患者报告结局无显著关联。作者建议术者避免偏心距减小超过20 mm以优化功能结局。
要点
- 偏心距减小超过20 mm与WOMAC疼痛评分较差相关(P=0.005)。
- 偏心距减小超过20 mm与WOMAC活动评分较差相关(P=0.015)。
- 偏心距减小不超过20 mm及偏心距增大与患者报告结局无显著关联。
核心结论
- 本研究显示全髋关节置换术后偏心距减小超过20 mm与WOMAC疼痛和活动评分较差相关。
- 作者建议术者避免偏心距减小超过20 mm以优化功能结局。
研究设计与样本
- 对前瞻性患者队列进行回顾性分析,纳入接受择期初次全髋关节置换术且随访至少12个月的患者共414例。
- 分析术后平片偏心距并与对侧天然髋关节比较,术前及术后12个月评估WOMAC和VR-12评分。
主要发现
- 回归分析表明偏心距减小超过20 mm者WOMAC疼痛评分(P=0.005)和活动评分(P=0.015)较偏心距维持者更差。
- WOMAC功能评分(P=0.063)、WOMAC全局评分(P=0.025)及VR-12评分未受影响(躯体P=0.656;心理P=0.815)。
- 偏心距减小不超过20 mm及偏心距增大与患者报告结局无显著关联(P值范围0.102至0.995)。
临床怎么用
- 作者建议术者避免偏心距减小超过20 mm以优化功能结局。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Conflicting reports exist about the effect of offset variation on functional outcomes following total hip arthroplasty. Reproducing native hip offset is thought to optimize function by restoring biomechanics and appropriately tensioning the hip abductor muscles. The aim of this study is to assess the effect of failing to restore global hip offset in comparison to the native contralateral hip. METHODS: A retrospective analysis of a prospective patient cohort was performed on patients undergoing an elective primary total hip arthroplasty. A total of 414 patients who had a minimum of 12 months of follow-up were included. Postoperative plain radiographs were analyzed for offset and compared to the contralateral native hip. Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Veterans RAND 12 (VR-12) scores were assessed preoperatively and at 12 months postoperatively. RESULTS: Regression analyses indicated that a reduction in offset of >20 mm resulted in worse WOMAC pain (P = .005) and motion (P = .015) scores compared to those with maintained offset. WOMAC function (P = .063), global (P = .025), and VR-12 scores were not affected (physical P = .656; mental P = .815). Reduction in offset up to 20 mm and increased offset were not significantly associated with patient-reported outcome measures (P-values ranged from .102 to .995). CONCLUSION: This study demonstrated an association between reduction in offset by >20 mm and worse WOMAC pain and motion scores following total hip arthroplasty. Surgeons should avoid decreases in offset >20 mm in order to optimize functional outcomes.
引用
- Bullen ME, Babazadeh S, van Bavel D, et al. Reduction in Offset Is Associated With Worse Functional Outcomes Following Total Hip Arthroplasty. J Arthroplasty. 2022. PMID: 36096271. doi:10.1016/j.arth.2022.09.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。