全髋关节置换术临床重要变化指标:一项系统综述
该系统综述依据PRISMA指南检索MEDLINE 2008至2020年文献,纳入16项研究共24,487例全髋关节置换术患者,报告11种患者报告结局测量工具。结果显示最小临床重要差异(MCID)最常被报告,最小可检测变化(MDC)、实质临床获益(SCB)和可接受症状状态(PASS)使用较少,且文献在患者报告结局测量工具的使用和解读上缺乏一致性。
要点
- 16项研究共24,487例全髋关节置换术患者,报告了11种患者报告结局测量工具。
- MCID在7项研究(44%)中用分布法计算,2项(13%)用锚定法,2项(13%)用两种方法。
- MDC在2项研究中计算,PASS在1项研究中用锚定法报告,SCB在1项研究中用锚定法计算。
核心结论
- 文献在患者报告结局测量工具用于评估患者满意度方面缺乏使用和解读的一致性。
- MCID是最常报告指标,MDC、SCB和PASS使用相对较少;推导方法因所用患者报告结局测量工具而异,分布法更常用于MCID。
研究设计与样本
- 系统综述,依据PRISMA指南检索MEDLINE数据库2008年至2020年文献。
- 纳入标准为全文、英文、初次全髋关节置换术且至少1年随访、使用患者报告结局测量工具评估临床结局的指标、以及这些指标的原创推导研究。
- 共纳入16项研究(24,487例全髋关节置换术患者),报告11种不同的患者报告结局测量工具。
主要发现
- MCID在7项研究(44%)中用分布法计算,2项研究(13%)用锚定法计算,2项研究(13%)用两种方法计算。
- MDC在2项研究中计算。
- PASS在1项研究中用锚定法报告。
- SCB在1项研究中用锚定法计算。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although patient-reported outcome measures (PROMs) have become a regularly used metric, there is little consensus on the methodology used to determine clinically relevant postoperative outcomes. We systematically reviewed the literature for studies that have identified metrics of clinical efficacy after total hip arthroplasty (THA) including minimal clinically important difference (MCID), patient acceptable symptom state (PASS), minimal detectable change (MDC), and substantial clinical benefit (SCB). METHODS: A systematic review examining quantitative metrics for assessing clinical improvement with PROMs following THA was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines using the MEDLINE database from 2008 to 2020. Inclusion criteria included full texts, English language, primary THA with minimum 1-year follow-up, use of metrics for assessing clinical outcomes with PROMs, and primary derivations of those metrics. Sixteen studies (24,487 THA patients) met inclusion criteria and 11 different PROMs were reported. RESULTS: MCIDs were calculated using distribution methods in 7 studies (44%), anchor methods in 2 studies (13%), and both methods in 2 studies (13%). MDC was calculated in 2 studies, PASS was reported in 1 study using anchor-based method, and SCB was calculated in 1 study using anchor-based method. CONCLUSION: There is a lack of consistency in the literature regarding the use and interpretation of PROMs to assess patient satisfaction. MCID was the most frequently reported measure, while MDC, SCB, and PASS were used relatively infrequently. Method of derivation varied based on the PROM used; distribution method was more frequently used for MCID.
引用
- Tanghe KK, Beiene ZA, McLawhorn AS, et al. Metrics of Clinically Important Changes in Total Hip Arthroplasty: A Systematic Review. J Arthroplasty. 2022. PMID: 36115533. doi:10.1016/j.arth.2022.09.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。