全髋关节置换术中新型聚乙烯的应用:20至22年随访研究
这项前瞻性随机研究比较了Durasul高交联聚乙烯与氮气灭菌Sulene聚乙烯在全髋关节置换术中的长期效果,至少随访20年。Durasul组无因松动翻修或骨溶解影像学证据,20年累积翻修失败率为4.5%,而Sulene组为8.9%。Durasul组股骨头平均总穿透量显著低于Sulene组,20年时减少约70.0%。
要点
- Durasul组无因松动翻修或骨溶解影像学证据,Sulene组有4例因股骨假体松动翻修。
- 20年累积翻修失败率Durasul组4.5%(95%CI 0.8至13.6),Sulene组8.9%(95%CI 2.8至19.5)。
- 术后1至20年Durasul组平均总穿透量0.32 mm(SD 0.045),Sulene组1.07 mm(SD 0.13)(p < 0.001)。
核心结论
- 与Sulene相比,Durasul在非骨水泥全髋关节置换术中显著减少股骨头穿透,并在20年后带来更低的骨溶解和翻修率。
研究设计与样本
- 前瞻性随机研究,1999年1月至2001年12月间90例患者接受同一髋臼和股骨假体、28 mm金属股骨头,分别使用Durasul或Sulene内衬。
- 共66髋(该前瞻性随机研究)完成至少20年随访。
主要发现
- Durasul组无患者因松动翻修,也无骨溶解影像学证据;Sulene组有4例患者(4髋)因股骨假体松动翻修。
- 20年累积翻修失败率(考虑死亡竞争事件)Durasul组为4.5%(95%CI 0.8至13.6),Sulene组为8.9%(95%CI 2.8至19.5)。
- 术后1年平均磨损量Durasul组0.09 mm(SD 0.007),Sulene组0.24 mm(SD 0.015)(p < 0.001)。
- 术后1至20年平均总穿透量Durasul组0.32 mm(SD 0.045),Sulene组1.07 mm(SD 0.13)(p < 0.001)。
- 20年时Durasul组平均股骨头穿透量较Sulene组减少约70.0%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: A significant reduction in wear at five and ten years was previously reported when comparing Durasul highly cross-linked polyethylene with nitrogen-sterilized Sulene polyethylene in total hip arthroplasty (THA). We investigated whether the improvement observed at the earlier follow-up continued, resulting in decreased osteolysis and revision surgery rates over the second decade. METHODS: Between January 1999 and December 2001, 90 patients underwent surgery using the same acetabular and femoral components with a 28 mm metallic femoral head and either a Durasul or Sulene liner. A total of 66 hips of this prospective randomized study were available for a minimum follow-up of 20 years. The linear femoral head penetration rate was measured at six weeks, one year, and annually thereafter, using the Dorr method on digitized radiographs with a software package. RESULTS: In the Durasul group, no patients underwent revision due to loosening or showed radiological evidence of osteolysis. In the Sulene group, four patients (four hips) were revised due to femoral component loosening. The 20-year cumulative failure incidence in the presence of the competing event of death for revision surgery was 4.5% (95% confidence interval (CI) 0.8 to 13.6) in the Durasul group, and 8.9% (95% CI 2.8 to 19.5) in the Sulene group. The mean wear one year after surgery was 0.09 mm (SD 0.007) in the Durasul group and 0.24 (SD 0.015) in the Sulene group (p < 0.001). From one to 20 years after surgery, the mean total penetration was 0.32 mm (SD 0.045) in the Durasul group and 1.07 mm (SD 0.13) in the Sulene group (p < 0.001). Mean femoral head penetration at 20 years was approximately 70.0% less in the Durasul group than the Sulene group. CONCLUSION: The significant reduction in femoral head penetration obtained with the Durasul compared with Sulene in uncemented THA resulted in lower osteolysis and revision rates after 20 years.Cite this article: Bone Joint J 2022;104-B(9):1032-1038.
引用
- García-Rey E, Cruz-Pardos A, Saldaña L, et al. New polyethylenes in total hip arthroplasty : a 20- to 22-year follow-up study. Bone Joint J. 2022. PMID: 36047028. doi:10.1302/0301-620X.104B9.BJJ-2022-0434.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。