无骨水泥柄取出时股骨截骨或骨折的风险因素及个体化预测风险评分
该单中心回顾性队列纳入202例患者,评估36项候选预后因素,识别出「托架征」及2、6、12、13区骨接触为骨折或股骨截骨的独立预测因素,全局性肥大具有保护作用,并据此开发了AUC为0.924的预测评分。
要点
- 「托架征」与2、6、12、13区骨接触是骨折或股骨截骨的独立危险因素。
- 全局性肥大是骨折或股骨截骨的独立保护因素(OR:0.170)。
- Femorotomy INcidence Numeric评分模型区分度良好,AUC为0.924。
核心结论
- 骨折或股骨截骨的独立危险因素仅为X线评估指标(如托架征及2、6、12、13区骨接触),全局性肥大具有保护作用。
- 作者注意到区分基座与「托架征」的重要性,后者是柄固定的指标。
- 作者开发了骨折或股骨截骨的风险预测评分(Femorotomy INcidence Numeric评分),可作为评估早期股骨截骨风险的辅助工具。
研究设计与样本
- 单中心回顾性队列研究,纳入202例患者,评估36项候选预后因素。
主要发现
- 骨折或股骨截骨的独立预测因素包括:托架征(OR:10.857;95% CI:2.613-45.115;P = .001),定义为植入物表面与最近骨内膜之间的远端点焊。
- 2区骨接触(OR:4.700;95% CI:1.827-12.089;P = .001)、6区骨接触(OR:4.966;95% CI:1.823-13.530;P = .002)、12区骨接触(OR:9.660;95% CI:3.715-25.116;P < .0001)、13区骨接触(OR:2.958;95% CI:1.009-8.021;P = .033)为独立预测因素。
- 全局性肥大(OR:0.170;95% CI:0.036-0.806;P = .026)为独立预测因素,具有保护作用。
- 预测评分模型(Femorotomy INcidence Numeric评分系统)表现良好且区分度好,模型曲线下面积为0.924(95% CI:0.878-0.969)。
关键数值与推荐
- 托架征:OR 10.857(95% CI 2.613-45.115;P = .001)。
- 2区骨接触:OR 4.700(95% CI 1.827-12.089;P = .001)。
- 6区骨接触:OR 4.966(95% CI 1.823-13.530;P = .002)。
- 12区骨接触:OR 9.660(95% CI 3.715-25.116;P < .0001)。
- 13区骨接触:OR 2.958(95% CI 1.009-8.021;P = .033);全局性肥大:OR 0.170(95% CI 0.036-0.806;P = .026);模型AUC 0.924(95% CI 0.878-0.969)。
临床怎么用
- 作者开发的风险预测评分(Femorotomy INcidence Numeric评分)可作为辅助工具,用于评估早期股骨截骨的风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Femorotomy is a commonly used technique during cementless stem removal but should be preferred in selective revision cases to prevent intraoperative femoral fracture associated with deteriorated clinical outcome. Our aim was to assess the risk factors for fracture or femorotomy and develop a predictive risk stratification score. METHODS: A monocentric retrospective cohort including 202 patients was analyzed. Thirty six candidate prognostic factors were assessed. RESULTS: The following independent predictors of fracture or femorotomy were identified: presence of a "bracket sign" (Odds Ratio [OR]: 10.857; 95% Confidence interval [CI]: 2.613-45.115; P = .001) defined as a distal spot weld between the surface of the implant and closest endosteum, bone contact in zone 2 (OR: 4.700; 95% CI: 1.827-12.089; P = .001), 6 (OR: 4.966; 95% CI: 1.823-13.530; P = .002), 12 (OR: 9.660; 95% CI: 3.715-25.116; P < .0001), 13 (OR: 2.958; 95% CI: 1.009-8.021; P = .033), and global hypertrophy (OR: 0.170; 95% CI: 0.036-0.806; P = .026). The prognostic score, named Femorotomy INcidence Numeric scoring system, had good performance and discriminability; the area under the curve of the model was 0.924 (95% CI: 0.878-0.969). CONCLUSION: The only independent risk factors were those assessed on X-ray (eg, bracket sign, bone contact in zones 2, 6, 12, and 13), while global hypertrophy was protective. We noticed the importance of differentiating pedestals and "bracket signs"; the latter is an indicator of fixation of the stem. We developed a risk prediction score (Femorotomy INcidence Numeric score) of fracture or femorotomy that can be used as a companion tool to assess the risk for doing an early osteotomy of the femur.
引用
- Aubert T, Auberger G, Gerard P, et al. Risk Factors Associated With Femorotomy or Fracture During Cementless Stem Removal and Generation of an Individual Predictive Risk Score. J Arthroplasty. 2022. PMID: 36116687. doi:10.1016/j.arth.2022.09.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。