前交叉韧带移植物匹配:股四头肌腱与髌腱移植物及股骨前交叉韧带止点显微解剖的尸体比较
研究比较股四头肌腱-髌骨(QTB)与骨-髌腱-骨(BPTB)移植物和股骨前交叉韧带(ACL)止点的显微解剖,并评估移植物弯曲角。QTB止点宽度和厚度均大于ACL,BPTB则较小;BPTB在股骨隧道口弯曲程度大于QTB。
要点
- QTB止点宽度较ACL宽16%,厚度较ACL厚77%(P < .001)。
- BPTB止点宽度较ACL窄16%,厚度较ACL薄28%(P = .017)。
- BPTB的cGBA较ACL小64%,QTB与ACL无显著差异。
核心结论
- QTB移植物止点宽度和厚度显著大于ACL,BPTB移植物则显著小于ACL。
- ACL重建后GBA与伸直位cGBA的关系表明,在股骨隧道口BPTB比QTB弯曲更多。
研究设计与样本
- 控制性实验室研究,采用20对配对的人尸体膝关节(平均年龄82.5岁),膝关节固定于屈曲<10°。
- 对股骨ACL止点、QTB移植物和BPTB移植物进行组织学切片,Masson三色染色和甲苯胺蓝染色,显微镜下分析。
- 纳入18例接受QTB或BPTB自体移植物ACL重建的患者,术后1周CT图像评估GBA。
主要发现
- 股骨ACL、QTB和BPTB的平均止点宽度分别为7.81、9.07和6.54 mm;QTB较ACL宽16%,BPTB较ACL窄16%。
- 股骨ACL、QTB和BPTB的平均止点厚度分别为0.53、0.94和0.38 mm;QTB较ACL厚77%(P < .001),BPTB较ACL薄28%(P = .017)。
- 股骨ACL、QTB和BPTB的平均韧带附着角分别为20.3°、30.2°和33.3°;QTB和BPTB分别较ACL大49%和64%。
- 股骨ACL、QTB和BPTB的平均cGBA分别为33.9°、35.1°和12.3°;BPTB较ACL小64%,QTB与ACL无显著差异。
- 平均GBA为57.7°。
临床怎么用
- 作者指出,QTB移植物可能允许进行更解剖的ACL重建。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal graft choice between the bone-patellar tendon-bone (BPTB) and the quadriceps tendon remains controversial. Studies evaluating the microscopic anatomy of the quadriceps tendon-patellar bone (QTB) and BPTB grafts for anterior cruciate ligament (ACL) reconstruction are currently lacking. HYPOTHESIS: The relationship between post-ACL reconstruction graft bending angle (GBA) and the angle corresponding to the GBA (cGBA) would indicate that the BPTB can bend more than the QTB at the femoral tunnel aperture. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty paired human cadaveric knees fixed at <10° of knee joint flexion (mean age, 82.5 years) underwent histological sectioning and staining with Masson trichrome and toluidine blue. The femoral ACL insertion, QTB graft, and BPTB graft were microscopically analyzed. The width of the direct insertion, thickness of the uncalcified fibrocartilage and calcified fibrocartilage, ligament attachment angle, and cGBA for each group were measured. Eighteen patients who underwent ACL reconstruction with QTB or BPTB autograft were included for the evaluation of GBA using computed tomography images at 1 week postoperatively. RESULTS: The mean insertion widths of the femoral ACL, QTB, and BPTB were 7.81, 9.07, and 6.54 mm, respectively. The QTB was 16% wider than the ACL, while the BPTB was 16% narrower than the ACL. The mean insertion thicknesses of the femoral ACL, QTB, and BPTB were 0.53, 0.94, and 0.38 mm, respectively. The QTB was 77% thicker than the ACL (P < .001), while the BPTB was 28% thinner than the ACL (P = .017). The mean ligament attachment angles of the femoral ACL, QTB, and BPTB were 20.3°, 30.2°, and 33.3°, respectively, and the QTB and the BPTB were 49% and 64% larger, respectively, than the ACL. The mean cGBAs of the femoral ACL, QTB, and BPTB were 33.9°, 35.1°, and 12.3°, respectively. The BPTB was 64% smaller than the ACL, while there was no significant difference between the QTB and the ACL. The mean GBA was 57.7°. CONCLUSION: The insertion width and thickness were significantly greater and smaller in the QTB and BPTB grafts, respectively, than in the ACL. The relationship between GBA after ACL reconstruction and cGBA in knee extension indicates that at the femoral tunnel aperture, the BPTB can bend more than the QTB. CLINICAL RELEVANCE: QTB graft may allow more anatomic ACL reconstruction to be performed.
引用
- Kinoshita T, Hashimoto Y, Iida K, et al. ACL Graft Matching: Cadaveric Comparison of Microscopic Anatomy of Quadriceps and Patellar Tendon Grafts and the Femoral ACL Insertion Site. Am J Sports Med. 2022. PMID: 35914183. doi:10.1177/03635465221110895
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。