文献速递运动医学关节外科

部分上关节囊重建联合自体肱二头肌长头腱增强关节镜下巨大肩袖撕裂修复:对再撕裂率的影响

Partial Superior Capsular Reconstruction to Augment Arthroscopic Repair of Massive Rotator Cuff Tears Using Autogenous Biceps Tendon: Effect on Retear Rate.
PubMed 文献 · Am J Sports Med · 2022-08-19

该队列研究比较关节镜下修复巨大肩袖撕裂时使用或不使用自体肱二头肌长头腱(LHBT)行部分上关节囊重建(pSCR)的2年临床与结构结局。结果显示,AR-LHBT组再撕裂率显著低于单纯修复组(14% vs 46%),疼痛和功能评分改善更优。

要点

  • AR-LHBT组2年再撕裂率14%,显著低于单纯修复组的46%(P < .01)。
  • AR-LHBT组ASES评分77.23 ± 7.45 vs AR组71.04 ± 9.28(P < .01),VAS评分1.64 ± 1.03 vs 2.12 ± 1.06(P < .01)。
  • AR-LHBT组前屈和 abduction 活动度显著更优,但外旋活动度AR组更优(59.5 ± 10.55 vs 54.43 ± 10.55;P < .01)。

核心结论

  • 使用自体LHBT行pSCR增强巨大肩袖撕裂修复,与单纯修复相比再撕裂率明显降低,疼痛和功能结局适度改善。

研究设计与样本

  • 队列研究,证据等级3级;纳入2015年至2017年间符合选择标准的106例可修复巨大后上方肩袖撕裂患者,分为AR组(50例)和AR-LHBT组(56例)。

主要发现

  • 术后24个月两组ASES评分、VAS评分和主动活动度均较术前显著改善(P < .01)。
  • AR-LHBT组2年随访时ASES评分77.23 ± 7.45 vs AR组71.04 ± 9.28(P < .01),VAS评分1.64 ± 1.03 vs 2.12 ± 1.06(P < .01)。
  • AR-LHBT组前屈活动度155(IQR 150-160)vs AR组150(IQR 140-170),P < .01;外展活动度150(IQR 140-157.5)vs AR组120(IQR 100-140),P < .01。
  • 外旋活动度AR组59.5 ± 10.55 vs AR-LHBT组54.43 ± 10.55(P < .01),AR组显著更优。
  • 2年超声随访再撕裂率AR组46% vs AR-LHBT组14%(P < .01)。

临床怎么用

  • 作者认为,对于巨大肩袖撕裂,使用LHBT行pSCR增强修复可降低再撕裂率并适度改善疼痛和功能结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Massive rotator cuff tears have a high incidence of postoperative retear that can reach 90%. It is still unclear which intervention may reduce the incidence of retear and improve the functional and clinical outcomes. PURPOSE/HYPOTHESIS: The purpose of this study was to investigate the clinical and structural outcomes at 2 years after repair of reparable massive rotator cuff tears with and without the use of partial superior capsular reconstruction (pSCR), using the autologous long head of the biceps tendon (LHBT) as a graft. It was hypothesized that augmentation with a pSCR would decrease retear rates. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: The authors compared arthroscopic repair of massive posterosuperior rotator cuff tears with and without augmentation using the LHBT for pSCR between 2015 and 2017. After applying the selection criteria, 106 patients were included in the study and distributed into 2 groups of 50 and 56 patients. Patients in the first group (50 patients) underwent arthroscopic repair without use of the LHBT (AR group), and patients in the second group (56 patients) underwent arthroscopic repair with use of the LHBT for pSCR (AR-LHBT group). The structural outcome was evaluated by ultrasound at 2 years of follow-up. Function and pain were evaluated preoperatively and at the 2-year follow-up using the American Shoulder and Elbow Surgeons (ASES) score and visual analog scale (VAS). Pre- and postoperative active range of motion, including forward elevation, external rotation, and abduction, were also documented. RESULTS: No significant differences were found between groups regarding the baseline characteristics. After 24 months, both groups showed significant improvement from preoperative ASES scores, VAS score, and active range of motion (P < .01 for all). Patients in the AR-LHBT group showed significant improvements in postoperative functional and pain scores compared with the AR group in all measurements at the 2-year follow-up (ASES score: 77.23 ± 7.45 vs 71.04 ± 9.28, P < .01; VAS score: 1.64 ± 1.03 vs 2.12 ± 1.06, P < .01). Final range of motion was significantly increased for the AR-LHBT group for forward elevation (155 [interquartile range {IQR}, 150-160] vs 150 [IQR, 140-170]; P < .01) and abduction (150 [IQR, 140-157.5] vs 120 [IQR, 100-140]; P < .01), but external rotation was significantly greater for the AR group (54.43 ± 10.55 vs 59.5 ± 10.55; P < .01). Postoperative ultrasonography at the 2-year follow-up revealed a higher retear rate in the AR group than in the AR-LHBT group (46% vs 14%; P < .01). CONCLUSION: Use of the LHBT for pSCR to augment massive rotator cuff tears resulted in markedly lower retear rates and modestly improved pain and function outcomes compared with repair alone.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Llinás PJ, Bailie DS, Sanchez DA, et al. Partial Superior Capsular Reconstruction to Augment Arthroscopic Repair of Massive Rotator Cuff Tears Using Autogenous Biceps Tendon: Effect on Retear Rate. Am J Sports Med. 2022. PMID: 35983981. doi:10.1177/03635465221112659

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。