文献速递关节外科

人工智能在全髋与全膝关节置换术影像分析中的应用:范围综述

Artificial intelligence for image analysis in total hip and total knee arthroplasty : a scoping review.
PubMed 文献 · Bone Joint J · 2022-01-01

该范围综述系统检索Embase、MEDLINE和PubMed,纳入12项研究,分析人工智能(AI)在全髋关节置换术(THA)和全膝关节置换术(TKA)术后X线片分析中的应用与准确性。AI在假体识别、失败风险预测、松动诊断和髋臼角度测量方面表现良好,但11/12项研究存在方法学局限且无外部验证,证据水平不足以支持广泛临床使用。

要点

  • AI假体识别AUC 0.992至1,多数算法准确率>90%,训练X线片550至320,000张。
  • AI预测THA后脱位风险(随访5年确定)AUC 76.67,训练X线片8,500张。
  • 12项研究中11项存在方法学局限致高偏倚风险,且无一进行外部验证。

核心结论

  • 这些研究显示AI前景可观,虽已能以较高精度分析图像,但目前缺乏高级别证据支持其广泛临床使用。
  • 应鼓励进一步研究,设计遵循标准报告指南的稳健研究,以开发易于转化至真实世界条件的AI模型。

研究设计与样本

  • 范围综述,遵循PRISMA-ScR扩展版和Arksey与O'Malley框架。
  • 系统检索Embase、MEDLINE和PubMed数据库。
  • 采用改良的非随机研究方法学指数(MINORS)工具评估研究质量。

主要发现

  • 共 identified 455项研究,仅12项符合纳入标准。
  • 12项中9项报告假体识别,3项描述预测假体失败风险。
  • 12项中3项将AI性能与骨科医生比较。
  • AI识别假体AUC 0.992至1,多数算法准确率>90%,使用550至320,000张训练X线片。
  • AI预测THA后脱位风险(随访5年确定)AUC 76.67,使用8,500张训练X线片。

关键数值与推荐

  • AI诊断髋假体松动准确性良好(准确率88.3%;420张训练X线片)。
  • AI测量术后髋臼角度与人类相当(平均绝对差1.35°至1.39°)。
  • 12项研究中11项存在数项方法学局限,引入高偏倚风险。
  • 12项研究均未进行外部验证。

临床怎么用

  • 原文未据此给出推荐。
  • 作者认为目前缺乏高级别证据支持AI影像分析在THA和TKA术后监测中的广泛临床使用。
  • 作者建议鼓励进一步研究,设计遵循标准报告指南的稳健研究,以开发易于转化至真实世界条件的AI模型。

局限性

  • 12项研究中11项存在数项方法学局限,引入高偏倚风险。
  • 12项研究均未进行外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. METHODS: The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O'Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy. RESULTS: Of the 455 studies identified, only 12 were suitable for inclusion. Nine reported implant identification and three described predicting risk of implant failure. Of the 12, three studies compared AI performance with orthopaedic surgeons. AI-based implant identification achieved AUC 0.992 to 1, and most algorithms reported an accuracy > 90%, using 550 to 320,000 training radiographs. AI prediction of dislocation risk post-THA, determined after five-year follow-up, was satisfactory (AUC 76.67; 8,500 training radiographs). Diagnosis of hip implant loosening was good (accuracy 88.3%; 420 training radiographs) and measurement of postoperative acetabular angles was comparable to humans (mean absolute difference 1.35° to 1.39°). However, 11 of the 12 studies had several methodological limitations introducing a high risk of bias. None of the studies were externally validated. CONCLUSION: These studies show that AI is promising. While it already has the ability to analyze images with significant precision, there is currently insufficient high-level evidence to support its widespread clinical use. Further research to design robust studies that follow standard reporting guidelines should be encouraged to develop AI models that could be easily translated into real-world conditions. Cite this article: Bone Joint J 2022;104-B(8):929-937.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Gurung B, Liu P, Harris PDR, et al. Artificial intelligence for image analysis in total hip and total knee arthroplasty : a scoping review. Bone Joint J. 2022. PMID: 35909383. doi:10.1302/0301-620X.104B8.BJJ-2022-0120.R2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。