全膝关节置换假体新型多层涂层安全:随机对照试验10年结果
这项随机对照试验将120例全膝关节置换患者随机分为新型多层低致敏涂层假体组与标准假体组,比较血清金属离子水平、患者报告结局与假体生存率至10年随访。两组患者报告结局改善相当且此后保持稳定,多数患者金属离子水平低于检测限,仅标准组钴水平在5年和10年随访时轻度升高但均低于3 μg/L,两组10年累积生存率均为98%。结论认为新型涂层系统未出现问题,未测得金属离子血清水平的相关升高。
要点
- 两组患者报告结局术后改善相当且此后保持稳定,10年累积生存率均为98%。
- 多数患者血清金属离子水平低于检测限,仅标准组钴水平在5年和10年随访时轻度升高,但所有患者值均低于3 μg/L。
- 结论认为新型涂层系统未出现问题,未测得金属离子血清水平的相关升高,两组假体生存率均优良。
核心结论
- 新型涂层系统未出现问题,未测得金属离子血清水平的相关升高。
- 标准全膝关节置换假体组观察到钴血清水平轻度升高,但未达到临界值。
- 新型涂层系统患者报告结局与标准假体相当,两组假体生存率均优良。
研究设计与样本
- 随机对照试验,共120例患者随机接受同一膝关节系统的涂层或标准全膝关节置换假体。
- 术前及至10年随访评估血清金属离子水平(钴、铬、钼、镍)、牛津膝关节评分(OKS)、SF-36及UCLA活动量表。
- 24例患者死亡,每组各1例翻修,最终85例患者完成随访。
主要发现
- 两组术后患者报告结局改善相当,此后评分保持稳定。
- 多数患者血清金属离子水平低于检测限。
- 仅标准组钴水平在5年和10年随访时轻度升高,但所有患者值均低于3 μg/L。
- 两组10年累积生存率均为98%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This randomized-controlled trial was initiated to compare a new multilayer hypoallergenic coating system with the standard implant in total knee arthroplasty (TKA) in terms of serum metal ion levels, patient-reported outcomes (PROs), and implant survival. METHODS: A total of 120 patients were randomized to receive a coated or standard TKA of the same knee system. Serum metal ion levels (ie, cobalt, chromium, molybdenum, and nickel) as well as knee function (Oxford Knee Score, OKS), quality of life (SF-36), and physical activity (UCLA activity scale) were assessed before surgery and until the 10 year follow-up. A total of 24 patients died and there was one revision in each group. This resulted in 85 patients who completed follow-up. RESULTS: Both groups demonstrated equally good improvement in PROs after surgery and constant score values thereafter. The majority of patients had metal ion serum levels below detection limit. Only cobalt levels demonstrated a slight increase in the standard group at 5- and 10-year follow-up. However, all patients displayed values below 3 μg/L. The cumulative 10-year survival was 98% in both groups. CONCLUSION: There were no problems with the new coating system. No relevant increase in metal ion serum levels were measured. A slight increase in cobalt serum levels in the standard TKA was noted, thus not reaching critical values. The new coating system demonstrated equally good PROs as the standard TKA. Excellent implant survival was observed in both groups. LEVEL OF EVIDENCE: I.
引用
- Lützner J, Beyer F, Lützner C, et al. A Novel Multilayer-Coating for Total Knee Arthroplasty Implants is Safe - 10-Year Results From a Randomized-Controlled Trial. J Arthroplasty. 2022. PMID: 35921997. doi:10.1016/j.arth.2022.07.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。