基于国家数据库数据,年龄对骨水泥型与非骨水泥型活动平台单髁膝关节置换术相对结局的影响
基于英国国家关节登记库与医院统计数据库,匹配12882例骨水泥型与非骨水泥型活动平台单髁膝关节置换术,按年龄分层比较翻修与再手术率。结果显示年轻年龄与两组更高翻修率相关,<60岁组非骨水泥固定较骨水泥固定翻修率更低,无菌性松动率低3倍。
要点
- 匹配后10年假体生存率:<60岁组骨水泥型81.4% vs 非骨水泥型86.7%(HR 0.73,CI 0.56-0.94,P=.02)。
- 60-69岁组10年生存率骨水泥型91.8% vs 非骨水泥型94.5%(HR 0.90,CI 0.67-1.22,P=.51)。
- <60岁组无菌性松动翻修率非骨水泥型0.5% vs 骨水泥型1.6%(P<.001),非骨水泥型低3倍。
核心结论
- 年轻年龄与骨水泥型和非骨水泥型单髁膝关节置换术两组更高的翻修率均相关。
- 在<60岁组中,非骨水泥固定较骨水泥固定降低了长期翻修率,无菌性松动率低3倍。
研究设计与样本
- 基于国家关节登记库与医院统计数据库的匹配队列研究,共纳入12882例骨水泥型与非骨水泥型单髁膝关节置换术,按患者与手术因素进行匹配。
- 患者按年龄分为3组:<60岁、60-69岁、≥70岁;采用Cox回归分析比较翻修率与再手术率。
- 证据等级为III级。
主要发现
- 匹配后10年假体生存率:<60岁组骨水泥型81.4%(CI 73.6-87.0) vs 非骨水泥型86.7%(CI 80.7-90.9),HR 0.73(CI 0.56-0.94,P=.02)。
- 匹配后10年假体生存率:60-69岁组骨水泥型91.8%(CI 88.9-94.0) vs 非骨水泥型94.5%(CI 92.9-95.7),HR 0.90(CI 0.67-1.22,P=.51)。
- 匹配后10年假体生存率:≥70岁组骨水泥型93.5%(CI 91.1-95.3) vs 非骨水泥型94.2%(CI 92.0-95.8),HR 1.0(CI 0.71-1.40,P=.99)。
- 再手术率观察到相同趋势。
- 无菌性松动翻修率:<60岁组非骨水泥型0.5% vs 骨水泥型1.6%(P<.001);60-69岁组非骨水泥型0.4% vs 骨水泥型1.3%(P=.002)。
关键数值与推荐
- 年龄分层:<60岁、60-69岁、≥70岁。
- 10年假体生存率<60岁组:骨水泥型81.4%(CI 73.6-87.0),非骨水泥型86.7%(CI 80.7-90.9),HR 0.73(CI 0.56-0.94,P=.02)。
- 10年假体生存率60-69岁组:骨水泥型91.8%(CI 88.9-94.0),非骨水泥型94.5%(CI 92.9-95.7),HR 0.90(CI 0.67-1.22,P=.51)。
- 10年假体生存率≥70岁组:骨水泥型93.5%(CI 91.1-95.3),非骨水泥型94.2%(CI 92.0-95.8),HR 1.0(CI 0.71-1.40,P=.99)。
- 无菌性松动翻修率:<60岁组非骨水泥型0.5% vs 骨水泥型1.6%(P<.001);60-69岁组非骨水泥型0.4% vs 骨水泥型1.3%(P=.002)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Unicompartmental knee arthroplasty (UKA) is an effective treatment for medial compartment arthritis. A challenge is that patients requiring knee arthroplasty are becoming younger. It is currently unknown what the relative performances of cemented and cementless UKAs are, in different age groups. METHODS: A total of 12,882 cemented and cementless UKAs from the National Joint Registry and Hospital Episodes Statistics databases were matched on patient and surgical factors. Patients were stratified into 3 groups: (1) <60 years; (2) 60-69 years; and (3) ≥70 years. Revision and reoperation rates were compared using Cox regression analyses. RESULTS: The 10-year implant survival for the matched cemented and cementless UKAs for (1) <60 years were 81.4% (CI 73.6-87.0) and 86.7% (CI 80.7-90.9) (hazard ratio [HR] 0.73, CI 0.56-0.94, P = .02); (2) for 60-69 years were 91.8% (CI 88.9-94.0) and 94.5% (CI 92.9-95.7) (HR 0.90, CI 0.67-1.22, P = .51); and (3) ≥70 years were 93.5% (CI 91.1-95.3) and 94.2% (CI 92.0-95.8) (HR 1.0, CI 0.71-1.40, P = .99). The same trend was observed for reoperations. In the <60 years and 60-69 years groups there were significantly fewer revisions for aseptic loosening in the cementless group (0.5% versus 1.6% [P < .001] and 0.4% versus 1.3% [P = .002], respectively). CONCLUSION: Younger ages were associated with higher revision rates in both cemented and cementless UKA groups. Cementless fixation has reduced long-term revision rates compared to cemented fixation in the <60 years group with aseptic loosening rates 3 times lower. LEVEL OF EVIDENCE: III.
引用
- Mohammad HR, Judge A, Murray DW, et al. The Effect of Age on the Relative Outcomes of Cemented and Cementless Mobile-Bearing Unicompartmental Knee Arthroplasty, Based on Data From National Databases. J Arthroplasty. 2022. PMID: 35952853. doi:10.1016/j.arth.2022.08.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。