文献速递关节外科

外科医生手术量与使用比例对活动平台单髁膝关节置换长期结局的影响:基于英格兰、威尔士、北爱尔兰和马恩岛国家关节登记数据的分析

The Influence of Surgeon Caseload and Usage on the Long-Term Outcomes of Mobile-Bearing Unicompartmental Knee Arthroplasty: An Analysis of Data From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man.
PubMed 文献 · J Arthroplasty · 2022-08-11

分析国家关节登记中34,277例内侧牛津单髁膝关节置换(UKA),按医生年手术量(<10 vs ≥10例/年)和使用比例(<20% vs ≥20%)分组比较10年翻修率。高手术量/高使用比例组骨水泥型和非骨水泥型UKA的10年生存率分别为90.0%和93.3%,高于低手术量/低使用比例组的82.8%和86.2%。结论认为活动平台UKA翻修率随手术量和使用比例增加而改善,非骨水泥固定与更高生存率相关。

要点

  • 高手术量/高使用比例组骨水泥型UKA 10年生存率90.0%,低手术量/低使用比例组为82.8%。
  • 高手术量/高使用比例组非骨水泥型UKA 10年生存率93.3%,低手术量/低使用比例组为86.2%。

核心结论

  • 活动平台UKA翻修率随外科医生UKA手术量和使用比例增加而改善。
  • 使用骨水泥型UKA且使用比例≥20%、手术量≥10例/年的外科医生,10年生存率为90%。
  • 更高的生存率与更高手术量、更高使用比例和非骨水泥固定相关。

研究设计与样本

  • 基于国家关节登记(英格兰、威尔士、北爱尔兰和马恩岛)的分析,共纳入34,277例内侧牛津UKA(骨水泥型23,707例,非骨水泥型10,570例)。
  • 按手术量分为低(<10例/年)和高(≥10例/年)两类,按使用比例分为低(<20%)和高(≥20%)两类,比较10年翻修率。

主要发现

  • 低手术量/低使用比例组骨水泥型UKA的10年生存率为82.8%(CI 81.6-83.9),非骨水泥型为86.2%(CI 72.1-93.4)。
  • 高手术量/高使用比例组骨水泥型UKA的10年生存率为90.0%(CI 89.2-90.6),非骨水泥型为93.3%(CI 91.3-94.8)。
  • 骨水泥型UKA中,高手术量/高使用比例组较低手术量/低使用比例组翻修率更低(HR 0.57,CI 0.52-0.63,P < .001)。
  • 骨水泥型UKA中,高手术量/低使用比例组(HR 0.74,CI 0.66-0.83,P < .001)和低手术量/高使用比例组(HR 0.86,CI 0.74-0.99,P = .04)的翻修率均低于低手术量/低使用比例组。

关键数值与推荐

  • 手术量分类阈值:低<10例/年,高≥10例/年。
  • 使用比例分类阈值:低<20%,高≥20%。
  • 证据等级:III级。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Unicompartmental knee arthroplasty (UKA) revision rates are variable and known to be influenced by a surgeon's caseload (number of UKAs performed annually) and usage (UKA as a proportion of overall knee arthroplasty practice). It is not known which is more important. We explored the influence of caseload and usage on cemented and cementless UKA. METHODS: A total of 34,277 medial Oxford UKAs (23,707 cemented and 10,570 cementless) from the National Joint Registry were analyzed. UKAs were subdivided by the following: (1) surgeon caseload, into low (<10 UKAs/y) and high (≥10 UKAs/y) categories; and (2) usage, into low (<20%) and high (≥20%) categories. The 10-year revision rates were compared. RESULTS: The 10-year survival of the low-caseload/low-usage cemented and cementless UKA was 82.8% (CI 81.6-83.9) and 86.2% (CI 72.1-93.4), respectively. The 10-year survival of the high-caseload/high-usage cemented and cementless UKA was 90.0% (CI 89.2-90.6) and 93.3% (CI 91.3-94.8), respectively. For cemented UKA, the high-caseload/high-usage group had lower revision rates (hazard ratio [HR] 0.57, CI 0.52-0.63, P < .001) compared to the low-caseload/low-usage group. The high-caseload/low-usage (HR 0.74, CI 0.66-0.83, P < .001) and the low-caseload/high-usage (HR 0.86, CI 0.74-0.99, P = .04) groups also had lower revision rates than the low-caseload/low-usage group. CONCLUSION: Mobile-bearing UKA revision rates improve with both increasing surgeon UKA caseload and usage. Surgeons using cemented UKA who have usage ≥20% and caseload ≥10/year had a 10-year survival of 90%. Higher survivorship was associated with higher caseload, higher usage, and cementless fixation. LEVELS OF EVIDENCE: III.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Mohammad HR, Judge A, Murray DW, et al. The Influence of Surgeon Caseload and Usage on the Long-Term Outcomes of Mobile-Bearing Unicompartmental Knee Arthroplasty: An Analysis of Data From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. J Arthroplasty. 2022. PMID: 35964854. doi:10.1016/j.arth.2022.08.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。