文献速递关节外科

翻修髋关节置换术中金属加强块的应用:系统综述与单臂荟萃分析

Metal Augments Used in Revision Hip Arthroplasty: A Systematic Review and Single-Arm Meta-Analysis.
PubMed 文献 · J Arthroplasty · 2022-08-12

该系统综述与单臂荟萃分析纳入19篇报告共647例患者(655髋),评估多孔金属加强块在翻修髋关节置换术中的疗效与安全性。术后Harris髋关节评分从术前约40分增至84分,髋旋转中心与泪滴间距从41.9 mm恢复至21.7 mm,髋臼翻修率4.7%,并发症发生率8.2%。作者结论认为金属加强块是矫正髋臼缺损安全有效的治疗选择。

要点

  • 术后Harris髋关节评分从术前约40分增至84分。
  • 髋旋转中心与泪滴垂直距离从术前41.9 mm恢复至术后21.7 mm。
  • 总体髋臼翻修率4.7%,并发症发生率8.2%。

核心结论

  • 作者结论认为,翻修髋关节置换术中使用的金属加强块是矫正髋臼缺损安全有效的治疗选择。

研究设计与样本

  • 系统综述与单臂荟萃分析,检索PubMed、Web of Science、EMBASE、Cochrane Library数据库及临床试验注册平台Clinicaltrials。
  • 共纳入19篇报告,涉及647例患者(655髋),手术时平均年龄63岁(范围24-106),平均随访66个月(范围11-204)。
  • 根据平均随访时间将患者分为3个亚组,分析功能评分、髋旋转中心恢复、假体翻修及并发症。

主要发现

  • Harris髋关节评分从术前平均约40分增至术后平均84分。
  • 髋旋转中心与泪滴的垂直距离从术前41.9 mm恢复至术后21.7 mm。
  • 总体髋臼翻修率为4.7%,并发症发生率为8.2%。
  • 再手术率、髋臼翻修率和并发症发生率在亚组间存在显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Porous metal augments are used in complex hip arthroplasty; however, few studies have assessed their efficacy and safety. This systematic review analyzed the use of augments in revision hip arthroplasty and summarized the clinical research findings. METHODS: We used combinations of "revision," "replacement," "arthroplasty," "augment," "acetabular," and "hip" to search PubMed, Web of Science, EMBASE, Cochrane Library databases, and clinical trial registration platform "Clinicaltrials" for relevant literature. The functional score, restoration of hip center of rotation, revision of implants, and complications were analyzed. Patients were divided into 3 subgroups according to the mean follow-up period. Overall, 19 reports involving 647 patients (655 hips) were selected. The mean age at the time of surgery was 63 years (range, 24-106) and the mean follow-up duration was 66 months (range, 11-204). RESULTS: Harris Hip Score increased from approximately a mean of 40 points preoperatively to a mean of 84 points postoperatively. The vertical distance between hip center of rotation and teardrop was restored from a preoperative distance of 41.9 to 21.7 mm postoperatively. The overall acetabular revision rate was 4.7%, and the incidence of complications was 8.2%. There were significant differences in the reoperation, acetabular revision, and complication rates among the subgroups. CONCLUSION: Metal augments used in revision hip arthroplasty are a safe and effective treatment option to correct acetabular defects.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Xiong C, Meng D, Ni R, et al. Metal Augments Used in Revision Hip Arthroplasty: A Systematic Review and Single-Arm Meta-Analysis. J Arthroplasty. 2022. PMID: 35964855. doi:10.1016/j.arth.2022.08.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。