文献速递关节外科骨质疏松与代谢性骨病

电化学应用羟基磷灰石于Bi-Metric股骨柄无骨水泥多孔表面可减少早期迁移并具有持久效果:一项随机五年随访放射立体测量研究

Electrochemically applied hydroxyapatite on the cementless porous surface of Bi-Metric stems reduces early migration and has a lasting effect : an efficacy trial of a randomized five-year follow-up radiostereometric study.
PubMed 文献 · Bone Joint J · 2022-01-01

53例患者随机接受仅多孔钛等离子喷涂涂层(P组)或附加BoneMaster涂层的Bi-Metric无骨水泥股骨柄(PBM组),放射立体测量随访至术后五年。术后三个月P组平均总平移0.95 mm、PBM组0.57 mm(p=0.047),骨量减少患者中PBM组迁移也更小;作者认为BoneMaster涂层可减少早期和中期迁移,尤其对骨量减少患者重要,但需进一步研究。

要点

  • 术后3个月P组平均总平移0.95 mm vs PBM组0.57 mm(p=0.047)。
  • 骨量减少患者术后3个月P组平均总平移1.61 mm vs PBM组0.73 mm(p=0.023)。
  • 骨量减少患者术后60个月P组平均总平移1.87 mm vs PBM组0.82 mm(p=0.011)。

核心结论

  • 与仅有多孔钛等离子喷涂涂层的股骨柄相比,BoneMaster涂层股骨柄的早期和中期迁移更少。
  • BoneMaster涂层似乎对股骨柄固定重要,尤其对骨量减少患者,但需进一步研究。

研究设计与样本

  • 随机对照试验,共53例患者随机接受仅多孔钛等离子喷涂涂层(P组)或附加BoneMaster涂层的多孔钛等离子喷涂涂层(PBM组)的Bi-Metric无骨水泥股骨柄。
  • 患者接受放射立体测量随访至术后五年。

主要发现

  • 术后三个月,P组平均总平移0.95 mm(95%CI 0.68至1.22)vs PBM组0.57 mm(95%CI 0.31至0.83),p=0.047。
  • 术后2至5年,P组总平移平均增加比PBM组多0.14 mm(95%CI 0.03至0.25),p=0.021。
  • 骨量减少患者(n=20)术后三个月平均总平移P组1.61 mm(95%CI 1.03至2.20)vs PBM组0.73 mm(95%CI 0.25至1.21),p=0.023。
  • 骨量减少患者术后60个月平均总平移P组1.87 mm(95%CI 1.24至2.50)vs PBM组0.82 mm(95%CI 0.30至1.33),p=0.011。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 尽管BoneMaster涂层似乎对股骨柄固定重要,尤其对骨量减少患者,但需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems. METHODS: A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery. RESULTS: At three months, the mean total translation (TT) was 0.95 mm (95% confidence interval (CI) 0.68 to 1.22) in the P group and 0.57 mm (95% CI 0.31 to 0.83) in the PBM group (p = 0.047). From two to five years, the TT increased by a mean of 0.14 mm (95% CI 0.03 to 0.25) more in the P group than in the PBM group (p = 0.021). In osteopenic patients (n = 20), the mean TT after three months was 1.61 mm (95% CI 1.03 to 2.20) in the P group and 0.73 mm (95% CI 0.25 to 1.21) in the PBM group (p = 0.023). After 60 months, the mean TT in osteopenic patients was 1.87 mm (95% CI 1.24 to 2.50) in the P group and 0.82 mm (95% CI 0.30 to 1.33) in the PBM group (p = 0.011). CONCLUSION: There was less early and midterm migration of cementless stems with BoneMaster coating compared with those with only a porous titanium plasma-sprayed coating. Although a BoneMaster coating seems to be important for stem fixation, especially in osteopenic patients, further research is warranted. Cite this article: Bone Joint J 2022;104-B(6):647-656.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Knudsen MB, Thillemann JK, Jørgensen PB, et al. Electrochemically applied hydroxyapatite on the cementless porous surface of Bi-Metric stems reduces early migration and has a lasting effect : an efficacy trial of a randomized five-year follow-up radiostereometric study. Bone Joint J. 2022. PMID: 35638207. doi:10.1302/0301-620X.104B6.BJJ-2021-1545.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。