文献速递关节外科

滑膜C反应蛋白是诊断假体周围关节感染的有用辅助指标

Synovial C-Reactive Protein is a Useful Adjunct for Diagnosis of Periprosthetic Joint Infection.
PubMed 文献 · J Arthroplasty · 2022-06-22

该研究回顾了2014至2021年间因翻修关节置换术前评估假体周围关节感染(PJI)的621例患者,采用2018年国际共识会议标准评估滑膜C反应蛋白(CRP)等生物标志物。滑膜CRP诊断PJI的曲线下面积(AUC)为0.951,敏感度74.2%、特异度98.0%;滑膜与血清CRP相关性良好(R=0.703),两者联合的AUC显著高于单用血清CRP(0.964 vs 0.926,P=0.016)。结论支持滑膜CRP作为PJI评估的辅助指标。

要点

  • 滑膜CRP诊断PJI的AUC为0.951(95%CI 0.932-0.970),敏感度74.2%、特异度98.0%。
  • 滑膜与血清CRP呈良好相关(R=0.703;95%CI 0.604-0.785)。
  • 血清与滑膜CRP联合的AUC显著高于单用血清CRP(0.964 vs 0.926,P=0.016)。

核心结论

  • 滑膜CRP在判断PJI存在时表现出极好的准确性,滑膜与血清CRP水平在翻修关节置换患者中呈良好相关,两者联合比单用血清检测更准确,这些发现支持将滑膜CRP作为PJI评估的辅助指标。

研究设计与样本

  • 回顾性分析了2014至2021年间因翻修关节置换术前评估PJI的621例患者,使用2018年国际共识会议标准评估血清CRP、红细胞沉降率、滑膜CRP、多形核白细胞百分比、白细胞计数和α-防御素等生物标志物。

主要发现

  • 194例患者存在PJI,394例为无菌性失败,33例结果不确定。
  • 滑膜CRP的AUC为0.951(95%CI 0.932-0.970),敏感度74.2%、特异度98.0%;血清CRP的AUC为0.926(95%CI 0.903-0.949),敏感度83.5%、特异度88.3%。
  • 滑膜与血清CRP呈良好相关(R=0.703;95%CI 0.604-0.785)。
  • 血清与滑膜CRP联合的AUC显著高于单用血清CRP(AUC 0.964 vs 0.926,P=0.016)。

关键数值与推荐

  • 采用2018年国际共识会议标准定义PJI。
  • 滑膜CRP诊断PJI的AUC为0.951(95%CI 0.932-0.970),敏感度74.2%、特异度98.0%。
  • 血清CRP诊断PJI的AUC为0.926(95%CI 0.903-0.949),敏感度83.5%、特异度88.3%。
  • 血清与滑膜CRP联合的AUC为0.964,显著高于单用血清CRP的0.926(P=0.016)。

临床怎么用

  • 作者认为这些发现支持将滑膜CRP作为PJI评估的辅助指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnostic utility of synovial C-reactive protein (CRP) has been debated for a while. Existing studies are limited by small sample sizes and using outdated criteria for periprosthetic joint infection (PJI). Furthermore, the relationship between synovial and serum CRP has rarely been investigated in the setting of PJI. This study aimed to evaluate the diagnostic utility of synovial CRP and to assess its relationship with serum CRP and other common biomarkers. METHODS: We reviewed 621 patients who underwent evaluation for PJI prior to revision arthroplasty from 2014 to 2021. Biomarkers, including serum CRP and erythrocyte sedimentation rate, synovial CRP, polymorphonuclear leukocyte percentage, white blood cell count, and alpha-defensin, were evaluated using the 2018 International Consensus Meeting criteria. RESULTS: In total, 194 patients had a PJI; 394 were considered aseptic failures and 33 were inconclusive. Synovial CRP showed an area under the curve (AUC) of 0.951 (95% CI, 0.932-0.970) with 74.2% sensitivity and 98.0% specificity, whereas, serum CRP had an AUC of 0.926 (95% CI, 0.903-0.949) with 83.5% sensitivity and 88.3% specificity. There was a good correlation between synovial and serum CRP (R = 0.703; 95% CI, 0.604-0.785). The combination of serum and synovial CRP yielded a significantly higher AUC than that obtained when using serum CRP alone (AUC 0.964 versus 0.926, P = .016). CONCLUSION: Synovial CRP demonstrated excellent accuracy when used to determine the presence of PJI. There was a good correlation between serum and synovial CRP levels in revision arthroplasty patients and the combined use of serum and synovial CRP proved to be more accurate than the serum test alone. These findings support the use of synovial CRP as an adjunct in the workup of PJI.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Baker CM, Goh GS, Tarabichi S, et al. Synovial C-Reactive Protein is a Useful Adjunct for Diagnosis of Periprosthetic Joint Infection. J Arthroplasty. 2022. PMID: 35750152. doi:10.1016/j.arth.2022.06.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。