金属对聚乙烯全髋关节置换术后不良局部组织反应翻修术的风险分层与疼痛结局
本研究回顾性分析141例因头颈锥度腐蚀导致不良局部组织反应(ALTR)行翻修全髋关节置换术的患者,采用广义线性混合模型分析疼痛结局。翻修术后疼痛几率降低44%(OR=0.56,95%CI:0.324-0.952),总体并发症率为17.7%。钴铬比率降低与术后并发症相关(2.8 vs 3.5;P=.002),而增加股骨头偏移未改变不稳/脱位率。
要点
- 翻修术后疼痛几率降低44%(OR=0.56,95%CI:0.324-0.952)。
- 总体并发症率为17.7%。
- 钴铬比率降低与术后并发症相关(2.8 vs 3.5;P=.002)。
核心结论
- 金属对聚乙烯全髋关节置换术后发生ALTR的患者行翻修手术可获得明显疼痛缓解。
- 增加股骨头偏移未改变不稳/脱位率。
- 当术前钴铬股骨头偏移大于可用陶瓷股骨头偏移而必须减小股骨头偏移时,未增加不稳/脱位率。
研究设计与样本
- 回顾性综述141例因头颈锥度腐蚀导致ALTR行翻修全髋关节置换术的患者。
- 疼痛结局采用广义线性混合模型分析。
- 并发症定义为不稳/脱位、感染、骨折、神经麻痹、下肢不等长或再手术。
主要发现
- 总体并发症率为17.7%。
- 翻修术后疼痛几率降低44%(OR=0.56,95%CI:0.324-0.952)。
- 基于股骨头偏移增加或减少的不稳/脱位无显著差异(P=.67)。
- 基于MRI所见外展肌丢失、积液大小和ALTR程度的不稳/脱位无显著差异(P=.73)。
- 血清钴升高(P=.31)和铬升高(P=.08)未预测并发症;钴铬比率降低与术后并发症相关(2.8 vs 3.5;P=.002)。
关键数值与推荐
- ALTR诊断基于患者病史和检查、假体风险、血清金属离子水平和影像学进行风险分层。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Revision total hip arthroplasty (THA) for adverse local tissue reactions (ALTRs) secondary to head-neck taper corrosion is associated with a high complication rate. Diagnosis of ALTR is based on risk stratification using the patient's history and examination, implant risk, serum metal ion levels, and imaging. The purpose of this study was to determine if stratification using similar risk factors is predictive of outcomes following revision THA for metal-on-polyethylene (MoP) ALTR. METHODS: We performed a retrospective review on 141 patients revised for ALTR due to head-neck taper corrosion. Pain outcomes following surgery were analyzed using a generalized linear mixed model. Complications were defined as instability/dislocation, infection, fracture, nerve palsy, leg-length discrepancy, or reoperation. RESULTS: The overall complication rate was 17.7%. The odds of having pain decreased by 44% after revision surgery (Odds Ratio = 0.56, 95% Confidence Interval: 0.324 to 0.952). There was no significant difference in instability/dislocation based on either increased or decreased head-neck offset (P = .67) or magnetic resonance imaging findings of abductor loss, effusion size, and degree of ALTR (P = .73). Increased serum cobalt (P = .31) and chromium (P = .08) levels did not predict complications; however, a decreased cobalt-chromium ratio was associated with postoperative complications (2.8 versus 3.5; P = .002). CONCLUSION: These findings are the first to suggest that patients who have ALTR after MoP THA undergoing revision surgery demonstrated major pain relief. Increasing femoral head offset did not change rates of instability/dislocation. In clinical scenarios where preoperative cobalt-chromium femoral head offsets were greater than available ceramic head offsets, a mandatory decrease in femoral head offset did not increase rates of instability/dislocation.
引用
- Daji AV, Workman KK, Yoo CJ, et al. Risk Stratification and Pain Outcomes Following Revision Total Hip Arthroplasty for Adverse Local Tissue Reactions. J Arthroplasty. 2022. PMID: 35738363. doi:10.1016/j.arth.2022.06.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。