文献速递关节外科运动医学

机械臂辅助与手动单髁膝关节置换术:MAKO机器人系统的系统综述与Meta分析

Robotic arm-assisted versus manual unicompartmental knee arthroplasty : a systematic review and meta-analysis of the MAKO robotic system.
PubMed 文献 · Bone Joint J · 2022-01-01

该系统综述与Meta分析比较了MAKO机械臂辅助单髁膝关节置换术(RAUKA)与手动内侧单髁膝关节置换术(mUKA)在假体定位精度、患者报告结局、并发症、生存率、成本效益和学习曲线方面的差异。共纳入14篇文章,结果显示MAKO RAUKA假体定位更精确,总体并发症率更低(OR 2.18,95%CI 1.06-4.49,p=0.040),但再干预、感染、KSS和WOMAC评分无差异。MAKO RAUKA具有成本效益,但与手术量直接相关。

要点

  • MAKO RAUKA假体定位精度优于手动mUKA,学习曲线为手术时间6例、精度0例。
  • MAKO RAUKA总体并发症率更低(OR 2.18,95%CI 1.06-4.49,p=0.040),但再干预和感染无差异。
  • KSS(均差1.64,95%CI -3.00至6.27,p=0.490)和WOMAC(均差-0.58,95%CI -3.55至2.38,p=0.700)无差异。

核心结论

  • MAKO RAUKA与假体定位精度改善相关,但与KSS和WOMAC评分的患者报告结局改善无关。
  • 未来更长期研究应报告功能结局(可能使用天花板效应最小的评分)和生存率,以评估MAKO RAUKA改善的精度是否带来更好的结局。

研究设计与样本

  • 系统综述与Meta分析,遵循PRISMA声明,于2021年11月检索PubMed、MEDLINE和Google Scholar。
  • 初筛共识别179篇文章,最终纳入14篇符合纳入标准的文章进行分析。
  • 纳入文章包括学习曲线1篇、植入物定位5篇、功能结局6篇、并发症5篇、生存率6篇、成本3篇。

主要发现

  • 学习曲线为手术时间6例、精度0例。
  • 有一致证据表明MAKO RAUKA植入物定位更精确。
  • Meta分析显示MAKO RAUKA总体并发症率更低(OR 2.18,95%CI 1.06至4.49,p=0.040)。
  • 再干预、感染、KSS(均差1.64,95%CI -3.00至6.27,p=0.490)和WOMAC评分(均差-0.58,95%CI -3.55至2.38,p=0.700)无差异。
  • MAKO RAUKA显示为成本效益良好的手术,但这与手术量直接相关。

关键数值与推荐

  • 总体并发症率:MAKO RAUKA组OR 2.18(95%CI 1.06至4.49),p=0.040。
  • KSS均差1.64(95%CI -3.00至6.27),p=0.490。
  • WOMAC评分均差-0.58(95%CI -3.55至2.38),p=0.700。
  • 学习曲线:手术时间6例,精度0例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 未来更长期研究应报告功能结局(可能使用天花板效应最小的评分)和生存率,以评估MAKO RAUKA改善的精度是否带来更好的结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). METHODS: Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta--Analysis statement. Search terms included "robotic", "unicompartmental", "knee", and "arthroplasty". Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. RESULTS: A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. CONCLUSION: MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541-548.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Zhang J, Ng N, Scott CEH, et al. Robotic arm-assisted versus manual unicompartmental knee arthroplasty : a systematic review and meta-analysis of the MAKO robotic system. Bone Joint J. 2022. PMID: 35491572. doi:10.1302/0301-620X.104B5.BJJ-2021-1506.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。