文献速递关节外科

直接前入路与直接外侧入路植入骨水泥型无领抛光锥形柄的骨水泥层质量与柄对线:单机构经验

Cement Mantle Quality and Stem Alignment in Cemented Collarless Polished Tapered Stems Implanted via the Direct Anterior and Direct Lateral Approaches: A Single Institution Experience.
PubMed 文献 · J Arthroplasty · 2022-05-14

该回顾性比较研究纳入232例使用骨水泥型无领抛光锥形柄的混合全髋关节置换术,经直接前入路(DAA,n=147)或直接外侧入路(DLA,n=85)植入。正位X线片上DLA组柄呈中立对线的比例高于DAA组(83.5%[n=71] vs 71.4%[n=105];P<.001),侧位对线及骨水泥层质量无差异,两种入路所有Gruen区平均骨水泥层厚度均≥2mm。

要点

  • DLA组正位X线片柄中立对线比例高于DAA组(83.5% vs 71.4%;P<.001)。
  • 两种入路在侧位X线片柄对线及骨水泥层质量上无差异。
  • 多变量分析显示Dorr B或C型股骨及男性与次优骨水泥层相关。

核心结论

  • 在本系列中,使用骨水泥型锥形抛光股骨假体行全髋关节置换术时,DAA与DLA相比冠状面柄对线不良发生率更高。
  • 侧位柄对线或骨水泥层质量未发现差异。

研究设计与样本

  • 回顾性比较研究,纳入232例使用骨水泥型无领抛光锥形柄的混合全髋关节置换术,DAA组n=147,DLA组n=85。

主要发现

  • 正位X线片上DLA组柄中立对线比例高于DAA组(83.5%[n=71] vs 71.4%[n=105];P<.001)。
  • 侧位X线片柄对线及骨水泥层质量两种入路间无差异。
  • 多变量分析显示与次优骨水泥层相关的因素包括Dorr B或C型股骨及男性。
  • 两种入路所有Gruen区平均骨水泥层厚度均≥2mm。

关键数值与推荐

  • 正位X线片柄中立对线:DLA组83.5%(n=71)vs DAA组71.4%(n=105),P<.001。
  • 所有Gruen区平均骨水泥层厚度≥2mm在两种入路中均达到。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study was to compare the stem alignment and the quality of cement mantle of collarless polished tapered cemented stems inserted through the direct anterior approach (DAA) and the direct lateral approach (DLA). METHODS: A comparative retrospective study of 232 hybrid total hip arthroplasties using a cemented collarless polished tapered stem through either the DAA (n = 147) or DLA (n = 85) was performed. Radiographic evaluation included stem alignment, cement mantle quality, and cement mantle thickness. RESULTS: On anteroposterior radiographs, stems implanted through the DLA were more likely to be in neutral alignment, than those implanted through the DAA (83.5%[n = 71] versus 71.4% [n = 105]; P = <.001). No difference between approaches was noted for stem alignment on lateral radiographs or cement mantle quality. Multivariate analysis revealed factors associated with suboptimal cement mantle and included Dorr type B or C femur as well as male gender. A mean cement mantle thickness ≥2mm was achieved in all Gruen zones for both approaches. CONCLUSION: In our series, the DAA was associated with a higher incidence of coronal plane stem malalignment compared to the DLA when using cemented tapered polished femoral components for total hip arthroplasty. No difference in lateral stem alignment or cement mantle quality was found.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pomeroy E, McGoldrick NP, Moody PW, et al. Cement Mantle Quality and Stem Alignment in Cemented Collarless Polished Tapered Stems Implanted via the Direct Anterior and Direct Lateral Approaches: A Single Institution Experience. J Arthroplasty. 2022. PMID: 35580767. doi:10.1016/j.arth.2022.05.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。