Paprosky II型股骨缺损翻修全髋关节置换术中短柄与长柄比较:非骨水泥远端固定模块化柄与初次单块锥形柄的5年随访对比研究
本研究基于前瞻性翻修登记系统纳入59例Paprosky II型股骨缺损患者,30例接受长远端固定模块化翻修柄、29例接受初次短锥形柄,随访比较下沉、并发症、再手术、假体生存及患者报告结局。模块化翻修柄的围手术期并发症和柄翻修更多,两组下沉及牛津髋关节评分、EQ-5D、静息与活动VAS疼痛无统计学差异。作者认为非骨水泥初次单块锥形柄临床结果与远端固定模块化柄相同,且并发症和柄翻修更少。
要点
- Paprosky II型股骨缺损翻修中,短锥形柄与长模块化柄的牛津髋关节评分、EQ-5D及VAS疼痛无统计学差异。
- 模块化翻修柄的围手术期并发症和柄翻修数量多于初次锥形短柄。
- 两组假体下沉无统计学差异,模块化柄并发症更多而临床结局与短柄相同。
核心结论
- 在Paprosky II型股骨缺损的翻修全髋关节置换术中,非骨水泥初次单块锥形股骨柄的临床结果与远端固定模块化柄相同,且并发症和柄翻修更少。
研究设计与样本
- 基于前瞻性翻修登记系统纳入59例连续Paprosky II型股骨缺损患者,30例接受长远端固定模块化翻修柄(Revision Stem,Lima Corporate),29例接受初次锥形短柄(Wagner Cone,Zimmer),前瞻性随访。
- 下沉和患者报告结局指标最短随访2年,并发症、再手术和翻修最短随访5年。
主要发现
- 两组在人口学、临床和手术相关特征方面具有可比性。
- 模块化翻修柄的围手术期并发症和柄翻修多于初次锥形柄。
- 两组在假体下沉、EuroQol 5 Dimension、牛津髋关节评分、静息VAS疼痛和活动VAS疼痛方面无统计学差异。
临床怎么用
- 作者认为,在Paprosky II型股骨缺损的翻修全髋关节置换术中,非骨水泥初次单块锥形股骨柄可显示与远端固定模块化柄相同的临床结果,且并发症和柄翻修更少。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In the revisions for Paprosky type II femoral defects, diaphyseal fixating femoral stems are commonly used. To preserve bone stock, the use of a shorter primary conical stem could be an adequate alternative. The objective of this study is to compare the results of a primary conical stem to the more commonly used diaphyseal fixating modular revision stem in revision total hip arthroplasty surgery with Paprosky type II femoral defects. METHODS: A total of 59 consecutive patients with Paprosky type II femoral defects from our prospective revision registry were included. Thirty patients who received a long distal fixating modular stem (Revision Stem, Lima Corporate) and 29 patients who received a primary conical short stem (Wagner Cone, Zimmer) were prospectively followed. Minimal follow-up time was 2 years for subsidence and patient-reported outcome measures and 5 years for complications, reoperation, and revision. We compared subsidence, perioperative complications, reoperations, femoral component survival, Oxford Hip Score, EuroQol 5 Dimension, visual analog scale (VAS) for pain at rest, and VAS for pain during activity between stems. RESULTS: Both groups were comparable regarding demographic, clinical, and surgery-related characteristics. We found more perioperative complications and stem revisions with the modular revision stem than with the primary conical stem. There were no statistical differences in subsidence, EuroQol 5 Dimension, Oxford Hip Score, and VAS for pain at rest or during activity between both stems. CONCLUSION: In revision total hip arthroplasty with Paprosky type II femoral defects, uncemented primary monobloc conical femoral stems showed the same clinical result as distal fixating modular stems with fewer complications and fewer stem revisions.
引用
- Willems JH, Smulders K, Innocenti M, et al. Stay Short or Go Long in Revision Total Hip Arthroplasty With Paprosky Type II Femoral Defects: A Comparative Study With the Use of an Uncemented Distal Fixating Modular Stem and a Primary Monobloc Conical Stem With 5-Year Follow-Up. J Arthroplasty. 2022. PMID: 35537612. doi:10.1016/j.arth.2022.05.009