文献速递关节外科

五种不同摩擦界面的全髋关节置换术的临床结局、金属离子水平、淋巴细胞谱和植入物生存率:平均10年随访研究

Clinical Outcomes, Metal Ion Levels, Lymphocyte Profiles, and Implant Survival Following Five Different Bearings of Total Hip Arthroplasty: A Mean 10-year Follow-up Study.
PubMed 文献 · J Arthroplasty · 2022-04-28

该研究比较了5种不同摩擦界面全髋关节置换术(THA)患者平均随访10.3年的临床结局、金属离子水平、淋巴细胞和植入物生存率,发现含金属界面组金属离子水平显著升高,金属对金属(MoM)和陶瓷对陶瓷(CoC)组植入物生存率显著低于其他组,主要因假瘤形成。

要点

  • 5组间Harris髋关节评分、WOMAC评分、关节活动度、血细胞计数及肝肾功能均无差异。
  • 含金属界面组金属离子水平显著升高,尤以MoM组为著。
  • MoM和CoC组植入物生存率分别为96.7%和93.3%,显著低于其他组,翻修主要因假瘤形成。

核心结论

  • 含金属界面的全髋关节置换术患者金属离子水平显著升高,尤其是金属对金属(MoM)组。
  • 陶瓷对陶瓷(CoC)和MoM组植入物生存率显著低于其他组,主要原因是假瘤形成。

研究设计与样本

  • 研究纳入2010年1月至2012年5月期间101例全髋关节置换术患者(134髋),分为金属对金属组(MoM,31髋)、金属对聚乙烯组(MoP,23髋)、陶瓷对金属组(CoM,21髋)、陶瓷对陶瓷组(CoC,33髋)和陶瓷对聚乙烯组(CoP,26髋)。
  • 平均随访时间为10.3年,评估Harris髋关节评分(HSS)、WOMAC评分、关节活动度(ROM)、血细胞计数及肝肾功能,采用高分辨率电感耦合等离子体质谱法(ICP-MS)测定血清和尿金属离子水平,并通过流式细胞术进行血液淋巴细胞分析。
  • 证据等级为治疗性II级。

主要发现

  • 5组间HSS、WOMAC评分、ROM、血细胞计数及肝肾功能均无差异。
  • 含金属界面组金属离子水平显著升高。
  • 流式细胞术显示各组间无差异。
  • 3例患者因假瘤形成接受翻修。
  • MoM组和CoC组植入物生存率分别为96.7%和93.3%,显著低于其他组。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Different bearings have been used in total hip arthroplasty (THA), but the long-term performance is still controversial. The purpose of this study was to investigate whether there are differences when comparing THAs with 5 different bearings at a long-term follow-up of more than 10 years. METHODS: From January 2010 to May 2012, 101 THA patients (134 hips) were divided into metal-on-metal group (MoM, 31 hips), metal-on-polyethylene group (MoP, 23 hips), ceramic-on-metal group (CoM, 21 hips), ceramic-on-ceramic group (CoC, 33 hips), and ceramic-on-polyethylene group (CoP, 26 hips). The mean follow-up period was 10.3 years. The Harris hip score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index scores (WOMAC), range of motion (ROM), blood cell count, and liver-kidney function were measured. Serum and urine metal ion levels were measured using high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) and a blood lymphocytes analysis was counted by flow cytometry. RESULTS: No difference was observed in the HSS, WOMAC, ROM, blood cell count, or liver-kidney function among any of the 5 groups. Metal ion levels were significantly elevated in metal-containing bearings. Flow cytometry showed that no differences were found. Revision was performed due to pseudotumor in 3 patients. The implant survival rate was 96.7% and 93.3% for the MoM and CoC groups, which was significantly lower compared with other groups. CONCLUSIONS: Metal ion levels were elevated significantly in metal-containing bearings, especially in MoM THA patients. The implant survival rate was significantly lower in CoC and MoM THAs, which was mainly due to pseudotumor formation. LEVEL OF EVIDENCE: Therapeutic Level II.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Zeng Y, Yin S, Liang S, et al. Clinical Outcomes, Metal Ion Levels, Lymphocyte Profiles, and Implant Survival Following Five Different Bearings of Total Hip Arthroplasty: A Mean 10-year Follow-up Study. J Arthroplasty. 2022. PMID: 35490981. doi:10.1016/j.arth.2022.04.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。