文献速递关节外科

初次全膝关节置换术中低黏度与高黏度骨水泥翻修率无差异

No Difference in Revision Rate Between Low Viscosity and High Viscosity Cement Used in Primary Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2022-05-05

基于1999至2020年间214,708例因骨关节炎行初次全膝关节置换术并使用骨水泥胫骨假体的病例,比较不同骨水泥黏度对翻修风险的影响。在高黏度骨水泥140,060例与低黏度骨水泥74,648例中,对于微稳定型、后稳定型和内侧轴心设计假体,全因翻修风险及无菌性松动翻修风险均无显著差异。

要点

  • 高黏度与低黏度骨水泥在全因翻修风险上无显著差异(微稳定型HR 1.07,后稳定型HR 1.03,内侧轴心型HR 1.06)。
  • 无菌性松动翻修风险在不同骨水泥黏度间亦无差异。
  • 骨水泥黏度在TKA翻修风险中的作用仍不明确,需进一步研究。

核心结论

  • 对于最常用的微稳定型、后稳定型和内侧轴心设计全膝关节置换术,骨水泥黏度在全因翻修风险或松动翻修风险上无差异。
  • 骨水泥黏度在TKA翻修风险中的作用仍不明确,需进一步研究。

研究设计与样本

  • 回顾性比较研究(证据等级III级),纳入1999年至2020年间因骨关节炎行初次全膝关节置换术并使用5种最常用骨水泥胫骨假体的214,708例手术。
  • 高黏度骨水泥组140,060例,低黏度骨水泥组74,648例,按假体稳定性类型(微稳定型、后稳定型、内侧轴心型)分别比较两种黏度的结局。

主要发现

  • 微稳定型假体:高黏度骨水泥组与低黏度骨水泥组全因翻修风险无差异(HR 1.07,95%CI 0.99-1.15,P=0.09)。
  • 后稳定型假体:高黏度骨水泥组与低黏度骨水泥组全因翻修风险无差异(HR 1.03,95%CI 0.95-1.11,P=0.53)。
  • 内侧轴心设计假体:高黏度骨水泥组与低黏度骨水泥组全因翻修风险无差异(HR 1.06,95%CI 0.80-1.41,P=0.67)。
  • 无菌性松动翻修风险在所有假体限制类型中两种骨水泥黏度间均无差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出骨水泥黏度在TKA翻修风险中的作用仍不明确,需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Loosening remains one of the most common reasons for revision total knee arthroplasty (TKA). Cement viscosity has a potential role in reducing revision rates for loosening. The aim of this study was to assess the outcome for loosening of the 5 most used cemented knee prostheses by constraint type, based on the cement viscosity type used. METHODS: There were 214,708 TKA procedures performed between 1999 and 2020 for a diagnosis of osteoarthritis using the 5 most commonly used minimally stabilized, posterior stabilized, and medial pivot design cemented tibial components. Only procedures with a cemented tibial component were included. Outcomes for two different cement viscosities, 140,060 high viscosity and 74,648 low viscosity cement, were compared for each fixation type within each of the three stability groups. RESULTS: There was no difference in a risk of all-cause revision when high viscosity cement was used compared to low viscosity cement for minimally stabilized prostheses (hazards ratio [HR] 1.07 [95% CI 0.99-1.15], P = .09), posterior stabilized prostheses (HR 1.03 [95% CI 0.95-1.11], P = .53), and medial pivot design prostheses (HR 1.06 [95% CI 0.80-1.41], P = .67). No difference was observed between cement viscosity types for any of the prosthesis constraint types when aseptic loosening was assessed. CONCLUSIONS: We found no difference in the risk of revision for any reason, or for loosening, with cement viscosity for the most commonly used minimally stabilized, posterior stabilized, and medial pivot TKA. The role of cement viscosity in the risk of TKA revision remains unclear and further research is required. LEVEL OF EVIDENCE: Level III Retrospective comparative study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Klasan A, Rainbird S, Peng Y, et al. No Difference in Revision Rate Between Low Viscosity and High Viscosity Cement Used in Primary Total Knee Arthroplasty. J Arthroplasty. 2022. PMID: 35525417. doi:10.1016/j.arth.2022.04.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。