文献速递关节外科

无领三锥度抛光骨水泥柄等线植入直接前入路全髋关节置换术至少10年随访

Minimum 10-Year Follow-Up of Total Hip Arthroplasty With a Collarless Triple-Tapered Polished Cemented Stem With Line-to-Line Implantation Using a Direct Anterior Approach.
PubMed 文献 · J Arthroplasty · 2022-05-16

回顾性连续纳入2009年2月至2011年8月接受直接前入路全髋关节置换术并使用Trilliance无领三锥度抛光骨水泥柄等线植入的130例患者(151髋),至少随访10年。平均随访10.7年,无菌性松动翻修股骨柄的10年累积生存率为100.0%,任何原因翻修股骨柄为97.6%(95%CI 95.4-100.0),任何原因翻修任一部件为96.5%(95%CI 93.8-99.3)。作者结论为临床与影像学结果优良。

要点

  • Trilliance无领三锥度抛光骨水泥柄等线植入直接前入路全髋置换至少10年随访结果优良。
  • 10年无菌性松动翻修股骨柄的累积生存率为100.0%,任何原因翻修股骨柄为97.6%。
  • 任何原因翻修任一部件的10年累积生存率为96.5%(95%CI 93.8-99.3)。

核心结论

  • Trilliance柄等线植入联合直接前入路在全髋关节置换术中至少10年随访时临床与影像学结果优良。

研究设计与样本

  • 回顾性连续队列研究,纳入2009年2月至2011年8月间接受初次全髋关节置换术的130例患者(151髋),至少随访10年。
  • 87.4%的患者诊断为基于发育性髋关节发育不良的继发性骨关节炎。
  • 评估临床与影像学结果及并发症,并进行生存分析,证据等级为IV级。

主要发现

  • 平均随访10.7年(范围10.0-12.1年),13髋(13例患者,6.8%)失访。
  • 术后1周136髋(93.8%)达到Barrack A级充分骨水泥固定。
  • 144髋(99.3%)的柄植入在3°范围内。
  • 高手术量(≥30例/年)与低手术量(<30例/年)医生之间未发现显著差异。

关键数值与推荐

  • 以无菌性松动翻修股骨柄为终点,10年累积生存率为100.0%。
  • 以任何原因翻修股骨柄为终点,10年累积生存率为97.6%(95%CI 95.4-100.0)。
  • 以任何原因翻修任一部件为终点,10年累积生存率为96.5%(95%CI 93.8-99.3)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Trilliance stem (B. Braun-Aesculap, Tuttlingen, Germany), a novel collarless triple-tapered polished stem, was introduced in 2009. The aim of this study is to evaluate the long-term clinical and radiological results of the Trilliance stem with line-to-line implantation in primary total hip arthroplasty using a direct anterior approach. METHODS: A consecutive retrospective series of 130 patients (151 hips) who underwent total hip arthroplasty between February 2009 and August 2011 were evaluated for a minimum of 10 years. Of these, 87.4% had a diagnosis of secondary osteoarthritis based on developmental hip dysplasia. Clinical and radiological results, complications were evaluated and survival analysis was performed. RESULTS: The mean follow-up was 10.7 years (range, 10.0-12.1). Thirteen hips (13 patients, 6.8%) were lost to follow-up. Adequate cementation (Barrack grade A) was achieved in 136 hips (93.8%) 1 week post-operatively. Nearly all (144 hips, 99.3%) had been inserted within the range of 3°. No significant differences were identified between high- (≥30 procedures/year) and low- (<30 procedures/year) volume surgeons. The Kaplan-Meier survival analysis with revision of the femoral component for aseptic loosening, revision of the femoral component for any reason and revision of either component for any reason as the end points, cumulative survivorship was 100.0%, 97.6% (95% confidence interval (CI) 95.4-100.0) and 96.5% (95% CI 93.8-99.3) at 10 years, respectively. CONCLUSION: The Trilliance stem with line-to-line implantation using a direct anterior approach has an excellent clinical and radiological outcome at a minimum of 10 years' follow-up. LEVEL OF EVIDENCE: Level IV, Retrospective cohort study.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Miyamoto S, Iida S, Suzuki C, et al. Minimum 10-Year Follow-Up of Total Hip Arthroplasty With a Collarless Triple-Tapered Polished Cemented Stem With Line-to-Line Implantation Using a Direct Anterior Approach. J Arthroplasty. 2022. PMID: 35588903. doi:10.1016/j.arth.2022.05.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。