文献速递关节外科

全髋关节置换术后交联聚乙烯与常规聚乙烯长期磨损相关并发症的Meta分析

Long-Term Wear-Related Complications of Cross-Linked Versus Conventional Polyethylene After Total Hip Arthroplasty: A Meta-Analysis.
PubMed 文献 · J Arthroplasty · 2022-05-12

该系统评价与Meta分析纳入14项至少随访10年的研究,比较全髋关节置换术中高交联聚乙烯(HXLPE)与常规聚乙烯(CPE)预防放射性骨溶解和翻修手术的长期疗效。共1175例全髋关节置换,HXLPE降低总体骨溶解风险(OR 0.30;P=0.001)、过度磨损风险(OR 0.10;P<.001)、线性磨损率(加权均数差0.09;P<.001)、总体磨损相关翻修风险(OR 0.06;P<.001)及无菌性松动翻修风险(OR 0.23;P=0.015)。比例Meta分析显示HXLPE组骨溶解、过度磨损和总体磨损相关翻修率分别为14%、8%和3%,CPE组分别为25%、33%和20%。

要点

  • HXLPE降低总体骨溶解风险(OR 0.30;P=0.001)和过度磨损风险(OR 0.10;P<.001)。
  • HXLPE降低总体磨损相关翻修风险(OR 0.06;P<.001)和无菌性松动翻修风险(OR 0.23;P=0.015)。
  • HXLPE组骨溶解、过度磨损和总体磨损相关翻修率分别为14%、8%和3%,CPE组分别为25%、33%和20%。

核心结论

  • 当前证据显示HXLPE大幅降低骨溶解率和磨损相关翻修手术率。
  • 由于聚乙烯磨损和骨溶解仍可导致翻修手术,需要持续的临床和取回研究分析长期结局。

研究设计与样本

  • 系统评价与Meta分析纳入14项比较HXLPE与CPE的研究,报告磨损相关并发症发生率,最短随访10年。
  • 共分析1175例全髋关节置换,检测到220例骨溶解和78例磨损相关翻修。
  • 采用配对Meta分析估计比值比(OR),采用比例Meta分析估计各并发症发生率。

主要发现

  • HXLPE降低总体骨溶解风险(OR 0.30;P=0.001)。
  • HXLPE降低过度磨损风险(OR 0.10;P<.001)。
  • HXLPE降低线性磨损率(加权均数差0.09;P<.001)。
  • HXLPE降低总体磨损相关翻修风险(OR 0.06;P<.001)。
  • HXLPE降低无菌性松动翻修风险(OR 0.23;P=0.015)。

关键数值与推荐

  • 比例Meta分析:HXLPE组骨溶解、过度磨损和总体磨损相关翻修率分别为14%、8%和3%,CPE组分别为25%、33%和20%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 由于聚乙烯磨损和骨溶解仍可导致翻修手术,需要持续的临床和取回研究分析长期结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Highly cross-linked polyethylene (HXLPE) liners have been developed to address the wear-related problems associated with conventional polyethylene (CPE) such as osteolysis or aseptic loosening in total hip arthroplasty (THA). In this systematic meta-analysis, we compared the long-term efficacy in preventing radiological osteolysis and revision surgery between HXLPE and CPE. METHODS: We included 14 studies that compared HXLPE and CPE reporting the incidence of wear-related complications with a minimum follow-up of 10 years. We investigated 5 wear-related complications: osteolysis, excessive wear, linear wear rate, revision surgery due to wear, and progress of osteolysis/aseptic loosening. We conducted a pair-wise meta-analysis to estimate odds ratio (OR) and a proportional meta-analysis to estimate the incidence of each complication. RESULTS: Among 1,175 THAs, 220 osteolysis and 78 wear-related revisions were detected. The use of HXLPE reduced the risk of overall osteolysis (OR 0.30; P = .001), excessive wear (OR 0.10; P < .001), linear wear rate (weighted mean difference 0.09; P < .001), the risk of overall wear-related revisions (OR 0.06; P < .001), and revisions due to aseptic loosening (OR 0.23; P = .015). As per the proportional meta-analysis, the pooled prevalence of osteolysis, excessive wear, and the overall wear-related revision rate were 14%, 8%, and 3% in HXLPE and 25%, 33%, and 20% in CPE, respectively. CONCLUSION: The current evidence shows that HXLPE dramatically reduced the rate of osteolysis and wear-related revision surgery. However, as polyethylene wear and osteolysis still lead to revision surgery, ongoing clinical and retrieval studies are required to analyze long-term outcomes.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Yoon BH, Park JW, Lee YK, et al. Long-Term Wear-Related Complications of Cross-Linked Versus Conventional Polyethylene After Total Hip Arthroplasty: A Meta-Analysis. J Arthroplasty. 2022. PMID: 35568139. doi:10.1016/j.arth.2022.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。