计算机导航与机器人辅助膝关节置换术中追踪针相关并发症的系统综述
该系统综述纳入36项研究(18篇病例报告共25例,18项非病例报告研究共7336例),评估计算机导航与机器人辅助膝关节置换术中追踪针相关并发症的发生率、时机、治疗与结局。非病例报告中针相关并发症总体发生率为1.4%,术中发生率最高者为追踪针脱位(0.6%),术后最高者为针道浅表感染(0.6%),多数术后并发症与胫骨部位相关(69%),所有并发症经治疗后在随访时均缓解。
要点
- 非病例报告研究中追踪针相关并发症总体发生率为1.4%。
- 术中发生率最高为追踪针脱位(0.6%),术后最高为针道浅表感染(0.6%)。
- 病例报告中最多见的针相关并发症为骨折(22例,81%)。
核心结论
- 计算机导航与机器人辅助膝关节置换术后的追踪针相关并发症相对少见。
- 针松动、浅表感染和骨折是最常被记录的并发症,血管损伤、骨化性肌炎和骨髓炎也可发生。
- 关节置换外科医生应考虑追踪针相关并发症的潜在可能,尤其在技术采用的早期阶段。
- 需要进一步研究追踪针相关并发症的患者危险因素。
研究设计与样本
- 系统综述,检索PubMed、Cochrane Central和Scopus数据库。
- 纳入所有记录计算机导航或机器人辅助全膝或部分膝关节置换术中追踪针相关并发症的临床研究。
- 共纳入36项研究:18篇病例报告(25例)和18项非病例报告研究(随机对照试验、队列研究和病例系列,共7336例)。
- 在数据可得时进行描述性统计分析。
主要发现
- 病例报告中最多见的针相关并发症为骨折(n=22;81%)。
- 非病例报告中针相关并发症总体发生率为1.4%。
- 术中发生率最高的并发症为追踪针脱位(0.6%)。
- 术后发生率最高的并发症为针道浅表感染(0.6%)。
- 多数术后并发症与胫骨部位相关(69%),所有并发症均经有效治疗并在随访时缓解。
临床怎么用
- 原文结论指出关节置换外科医生应考虑追踪针相关并发症的潜在可能,尤其在技术采用的早期阶段。
局限性
- 需要进一步研究追踪针相关并发症的患者危险因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Computer-assisted navigation (CAN) and robotic-assisted (RA) knee arthroplasty procedures carry unique risks of tracking pin-related complications. This systematic review aimed to quantitatively assess the incidence, timing, treatment, and clinical outcomes of all tracking pin-related complications following CAN and RA knee arthroplasty. METHODS: A systematic review was performed using PubMed, Cochrane Central and Scopus databases. All clinical studies that documented pin-related complications associated with the use of CAN or RA for total or partial knee arthroplasty were included. Descriptive statistics were analyzed when data were available. RESULTS: Thirty-six studies were included: 18 case reports (25 cases) and 18 randomized controlled trials, cohort studies and case series i.e., non-case reports (7,336 cases). The most common pin-related complication among case reports was fracture (n = 22; 81%). The overall rate of pin-related complications among non-case reports was 1.4%. The intraoperative and postoperative complication with the highest incidence were pin dislodgement (0.6%) and superficial pin site infections (0.6%), respectively. Most postoperative complications were related to the tibial site (69%). All complications were effectively treated and resolved at follow-up. CONCLUSION: Pin-related complications following CAN and RA knee arthroplasty are relatively uncommon. While pin loosening, superficial infections and fractures have been most commonly documented, other complications such as vascular injury, myositis ossificans, and osteomyelitis can also occur. The potential for pin-related complications should be considered by arthroplasty surgeons, especially during early stages of adoption. Further studies investigating patient risk factors for pin-related complications are warranted.
引用
- Thomas TL, Goh GS, Nguyen MK, et al. Pin-Related Complications in Computer Navigated and Robotic-Assisted Knee Arthroplasty: A Systematic Review. J Arthroplasty. 2022. PMID: 35537611. doi:10.1016/j.arth.2022.05.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。