一种用于改进股骨颈骨折固定术后上螺钉安全性评估的新型透视视图

A Novel Fluoroscopic View for Improved Assessment of the Safety of the Posterosuperior Screw in Femoral Neck Fracture Fixation.
PubMed 文献 · J Bone Joint Surg Am · 2022-02-15

本研究通过合成股骨模型和尸体标本确定能准确识别股骨颈后上螺钉部分穿出骨外(IOI)放置的透视视图,发现10例尸体标本中4枚(40%)螺钉穿出骨外且均在0°侧位视图下放置,-15° rollunder侧位视图识别IOI的敏感性为81.7%、特异性为92.2%,答题者总体准确率为68.8%。

要点

  • 标准正位和0°侧位透视下放置的后上螺钉中,40%(4/10)穿出骨外。
  • -15° rollunder侧位视图识别IOI螺钉的敏感性81.7%、特异性92.2%。
  • 答题者总体准确率68.8%,主治创伤骨科医师71.8%与住院医师67.4%无差异(p=0.173)。

核心结论

  • 外科医生常用标准正位和0°侧位透视安全放置螺钉,但许多螺钉为IOI。
  • 加用-15° rollunder侧位视图显著提高了股骨颈后上IOI螺钉的识别。
  • 未识别的IOI螺钉放置可能导致股骨头血供损伤。

研究设计与样本

  • 研究分两阶段:第一阶段在2个合成股骨模型(1个完全骨内、1个IOI)的后上区域放置3.2 mm导针,以5°间隔连续透视以确定能识别IOI导针放置的透视投影。
  • 第二阶段在10具尸体标本中采用标准后前位透视和两种侧位视图之一(颈与柄对齐即0°侧位,或-15° rollunder视图)放置倒三角的后上螺钉。
  • 最终透视视图(后前位及多个侧位和斜位)随机盲法由10名骨科住院医师和5名主治创伤骨科医师审阅,标本剥离软组织后检查螺钉穿孔。

主要发现

  • 答题者总体准确率为68.8%,主治创伤骨科医师为71.8%,住院医师为67.4%(p=0.173),两者无差异。
  • 观察者间信度为中等(κ=0.496)。
  • 解剖发现10枚螺钉中4枚(40%)穿出骨外,所有穿出骨外的螺钉均在使用0°侧位视图时放置。
  • -15° rollunder侧位视图识别IOI螺钉放置的敏感性为81.7%、特异性为92.2%,为最敏感和特异的视图。

关键数值与推荐

  • -15° rollunder侧位视图识别IOI螺钉的敏感性为81.7%、特异性为92.2%。
  • 0°侧位视图下放置的螺钉中4枚(40%)穿出骨外。
  • 答题者总体准确率68.8%,主治创伤骨科医师71.8% vs 住院医师67.4%(p=0.173),无差异。
  • 观察者间信度κ=0.496,为中等。

临床怎么用

  • 作者结论指出,加用-15° rollunder侧位视图显著提高了股骨颈后上IOI螺钉的识别。
  • 作者结论指出,未识别的IOI螺钉放置可能导致股骨头血供损伤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of the present study was to determine specific fluoroscopic views of the femoral neck to accurately identify partially extraosseous ("in-out-in"; IOI) placement of the posterosuperior screw for fixation of femoral neck fractures. METHODS: A 3.2-mm guide pin was placed in the posterosuperior aspect of 2 synthetic femur models: 1 entirely intraosseous and 1 IOI. Sequential fluoroscopic images were made at 5° intervals in order to identify which fluoroscopic projections identified IOI guide pin placement. These images were utilized to inform screw placement and assessment in the second phase of the study, which involved the use of cadaveric specimens. In Phase II, the posterosuperior screw of the inverted triangle was placed in 10 cadaveric specimens with use of a standard posteroanterior fluoroscopic view and 1 of 2 lateral views, either (1) neck in line with the shaft, i.e., 0° lateral; or (2) a -15° rollunder view. The final fluoroscopic views (i.e., the posteroanterior and multiple lateral and oblique views) were randomized and blinded for review by 10 orthopaedic residents and 5 attending orthopaedic traumatologists. Specimens were stripped of soft tissue and inspected for screw perforation. RESULTS: Overall accuracy of respondents was 68.8%, with no difference between the attending traumatologists (71.8%) and resident surgeons (67.4%; p = 0.173). Interobserver reliability was moderate (κ = 0.496). Dissection identified that 4 (40%) of 10 screws were extraosseous. All of the extraosseous screws were placed with use of the 0° lateral view. The -15° rollunder lateral view was the most sensitive (81.7%) and specific (92.2%) view for identifying IOI screw placement. CONCLUSIONS: Surgeons often utilize the standard posteroanterior and 0° lateral fluoroscopic views to safely place screws; however, many of these screws are IOI. The addition of a -15° rollunder lateral view significantly improved identification of IOI screws in the posterosuperior femoral neck. Unidentified IOI screw placement may result in damage to the blood supply of the femoral head.