文献速递运动医学关节外科

自体微碎片化脂肪抽吸组织增强关节镜下肩袖修复安全且有效改善短期临床与功能结果:一项随访24个月的前瞻性随机对照试验

Arthroscopic Rotator Cuff Repair Augmentation With Autologous Microfragmented Lipoaspirate Tissue Is Safe and Effectively Improves Short-term Clinical and Functional Results: A Prospective Randomized Controlled Trial With 24-Month Follow-up.
PubMed 文献 · Am J Sports Med · 2022-03-18

该前瞻性随机对照试验纳入44例磁共振成像确认的退行性后上肩袖撕裂患者,随机分为单排关节镜下肩袖修复联合术中注射自体微碎片化脂肪组织组(治疗组)与未注射组(对照组)。6个月随访时治疗组Constant-Murley评分显著优于对照组,其余随访点临床结果、再撕裂率、并发症率及不良事件数均无显著差异。结论认为术中注射自体微碎片化脂肪组织安全且有效改善单排关节镜下肩袖修复术后短期临床与功能结果。

要点

  • 6个月随访时治疗组Constant-Murley评分显著优于对照组(82.78±7.00分 vs 76.66±10.77分,P=0.0050)。
  • 其余随访点临床结果指标、再撕裂率、并发症率及不良事件数两组均无显著差异。
  • 共筛查177例,44例(每组22例)完成24个月随访。

核心结论

  • 该前瞻性随机对照试验表明,术中注射自体微碎片化脂肪组织在单排关节镜下肩袖修复术后安全,并有效改善短期临床与功能结果。

研究设计与样本

  • 随机对照试验,证据等级2级;连续纳入经磁共振成像确认的退行性后上肩袖撕裂患者,随机分为单排关节镜下肩袖修复联合术中注射经无酶技术处理的自体微碎片化脂肪组织组(治疗组)与未注射组(对照组)。
  • 共筛查177例患者,44例(每组22例)完成24个月随访;临床随访于术后3、6、12、18、24个月进行,术后18个月行患肩磁共振成像评估肌腱完整性与再撕裂率。

主要发现

  • 主要终点6个月随访时Constant-Murley评分治疗组显著优于对照组(均值±标准差:对照组76.66±10.77分,治疗组82.78±7.00分,P=0.0050)。
  • 其余随访点临床结果指标两组均无显著差异。
  • 再撕裂率、并发症率及不良事件数两组均无显著差异。

关键数值与推荐

  • 6个月随访Constant-Murley评分:对照组76.66±10.77分 vs 治疗组82.78±7.00分,P=0.0050,差异有统计学意义。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Autologous microfragmented lipoaspirate tissue has been recently introduced in orthopaedics as an easily available source of nonexpanded adipose-derived mesenchymal stem cells. Autologous microfragmented lipoaspirate tissue is expected to create a suitable microenvironment for tendon repair and regeneration. Rotator cuff tears show a high incidence of rerupture and represent an ideal target for nonexpanded mesenchymal stem cells. PURPOSE: To evaluate the safety and efficacy of autologous lipoaspirate tissue in arthroscopic rotator cuff repair. STUDY DESIGN: Randomized controlled trial; Level of evidence, 2. METHODS: Consecutive patients referring to the investigation center for surgical treatment of magnetic resonance imaging-confirmed degenerative posterosuperior rotator cuff tears were assessed for eligibility. Those who were included were randomized to receive a single-row arthroscopic rotator cuff repair, followed by intraoperative injection of autologous microfragmented adipose tissue processed with an enzyme-free technology (treatment group) or not (control group). Clinical follow-up was conducted at 3, 6, 12, 18, and 24 months; at 18 months after surgery, magnetic resonance imaging of the operated shoulder was obtained to assess tendon integrity and rerupture rate. RESULTS: An overall 177 patients were screened, and 44 (22 per group) completed the 24-month follow-up. A statistically significant difference in favor of the treatment group in terms of Constant-Murley score emerged at the primary endpoint at 6-month follow-up (mean ± SD; control group, 76.66 ± 10.77 points; treatment group, 82.78 ± 7.00 points; P = .0050). No significant differences in clinical outcome measures were encountered at any of the other follow-up points. No significant differences emerged between the groups in terms of rerupture rate, complication rate, and number of adverse events. CONCLUSION: This prospective randomized controlled trial demonstrated that the intraoperative injection of autologous microfragmented adipose tissue is safe and effective in improving short-term clinical and functional results after single-row arthroscopic rotator cuff repair. REGISTRATION: NCT02783352 (ClinicalTrials.gov identifier).

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Randelli PS, Cucchi D, Fossati C, et al. Arthroscopic Rotator Cuff Repair Augmentation With Autologous Microfragmented Lipoaspirate Tissue Is Safe and Effectively Improves Short-term Clinical and Functional Results: A Prospective Randomized Controlled Trial With 24-Month Follow-up. Am J Sports Med. 2022. PMID: 35302901. doi:10.1177/03635465221083324

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。