肩袖切开与修复状态下上关节囊的生物力学作用:一项序贯切开研究
研究在12具尸体肩关节上于0°、45°、90°外展下测试肩袖与上关节囊对上肱骨移位的独立贡献,发现两者均切开时移位显著大于完整及单独切开状态;动态测试提示肩袖贡献更大,肩袖修复可使移位恢复至接近完整状态。
要点
- 平衡三角肌载荷下0°与45°外展时,肩袖与上关节囊均切开者上肱骨移位显著大于完整及单独切开状态。
- 动态测试中肩袖缺损标本上肱骨移位较完整状态显著增加,而上关节囊切开时无差异。
- 肩袖修复后各外展角度与载荷条件下移位与完整状态相似。
核心结论
- 尸体研究中上关节囊与肩袖均在防止上肱骨移位中起重要作用,但动态测试提示肩袖贡献更大。
- 即使上关节囊在盂肱关节水平被切开,肩袖修复仍能有效防止上肱骨移位。
研究设计与样本
- 控制性实验室研究,12具尸体肩关节在0°、45°、90°外展下测试5种条件:肩袖/上关节囊完整、先切开肩袖、先切开上关节囊、两者均切开、肩袖修复。
- 配对标本随机分配至先切开肩袖或先切开上关节囊的测试条件。
- 测试包括2种静态条件(40 N三角肌载荷的平衡载荷、80 N三角肌载荷的上方向载荷)及主动外展中的1种动态条件。
- 采用混合设计双因素重复测量方差分析及Bonferroni校正比较测试条件,配对t检验比较完整与修复状态,显著性设定为P < .05。
主要发现
- 平衡三角肌载荷下0°与45°外展时,两者均切开的上肱骨移位显著大于完整状态及两种单独切开状态(所有比较P < .05)。
- 90°外展时组间及组内均未观察到显著差异。
- 上方向载荷下上述效应保持一致。
- 动态测试显示肩袖缺损标本上肱骨移位较完整状态显著增加(P = .027),而上关节囊切开时无差异。
- 肩袖修复状态在各外展角度与载荷条件下移位与完整状态相似(P > .05)。
临床怎么用
- 作者指出其数据为未来研究肩袖修复在上关节囊切开状态下的临床效果奠定基础。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Individual contributions of the rotator cuff (RC) and superior capsule (SC) to prevent superior translation of the humerus are not well understood. PURPOSE: To evaluate the relative contributions of the SC and RC to normal and pathologic shoulder biomechanics by determining their independent effects on superior humeral translation. STUDY DESIGN: Controlled laboratory study. METHODS: Twelve cadaveric shoulders were tested at 0º, 45º, and 90º of abduction under 5 conditions: intact RC/SC, RC sectioned first, SC sectioned first, both structures sectioned, and RC repair. Matched pairs were randomly assigned to the second or third testing condition (RC or SC sectioned first). Specimens were tested under 2 static conditions (40-N deltoid load [balanced load], 80-N deltoid load [superiorly directed load]) and 1 dynamic condition during active abduction. A mixed-design 2-way repeated-measures analysis of variance with Bonferroni adjustments was performed to compare testing conditions. Paired t tests were used to compare specimens in the intact state versus the repaired state. Significance was set at P < .05. RESULTS: During balanced deltoid loading at 0° and 45º, there was significantly greater humeral translation when both structures were sectioned as compared with the intact state and with both isolated sectioned states (P < .05 for all). No significant differences were observed between or within groups at 90º of abduction. These effects remained consistent with superiorly directed loading. Dynamic testing of both groups showed a significant increase in superior translation for specimens in which the RC was deficient versus the intact state (P = .027), with no difference when the SC was sectioned. The RC repair state returned translation to values similar to the intact state at all abduction angles and loading conditions (P > .05). CONCLUSION: In this cadaveric study, the SC and RC played an important role in preventing superior humeral translation; however, dynamic testing suggested preferential contribution of the RC. RC repair was effective in preventing superior humeral translation, even with a sectioned SC at the level of the glenohumeral joint. CLINICAL RELEVANCE: RC repair was effective in preventing superior humeral translation, even in the presence of a sectioned SC at the level of the glenohumeral joint in this cadaveric model. Our data lay the groundwork for future studies investigating the clinical effect of RC repair in an SC sectioned state.
引用
- DeFroda SF, Perry AK, Mehta N, et al. Biomechanical Role of the Superior Capsule in a Rotator Cuff Sectioned and Repaired State: A Sequential Sectioning Study. Am J Sports Med. 2022. PMID: 35323067. doi:10.1177/03635465221083651
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。