文献速递关节外科

模块化钛基板不依赖体重指数与力线不良均具有高生存率

High Survivorship of a Modular Titanium Baseplate Independent of Body Mass Index and Malalignment.
PubMed 文献 · J Arthroplasty · 2022-02-18

该回顾性研究纳入2004至2018年间接受初次全膝关节置换术并使用单一模块化钛基板(十字形龙骨、喷砂表面)的2949例患者,至少随访1年,平均随访7年,评估假体生存率及体重指数与术后力线不良的影响。结果显示85例(2.8%)翻修,其中46例(1.6%)为无菌性松动,失败与体重指数、性别、美国麻醉医师协会分级或Charlson合并症指数无关,体重指数(P=0.26)和力线不良(偏离中立机械轴超过3°,P=0.67)均无失败率差异,年龄与失败相关(失败组61岁 vs 65岁,P<0.01)。结论认为该设计在7年随访中无论体重指数或力线如何均达99%生存率,高黏度骨水泥技术一致,提示假体设计仍是影响生存率的重要变量。

要点

  • 2949例全膝关节置换术使用模块化钛基板,平均随访7年,假体生存率99%。
  • 翻修85例(2.8%),其中无菌性松动46例(1.6%)。
  • 失败与体重指数(P=0.26)及力线不良(P=0.67)无关,年龄与失败相关(61 vs 65岁,P<0.01)。

核心结论

  • 该模块化钛基板设计在7年随访中无论患者体重指数或力线如何均展示99%生存率。

研究设计与样本

  • 回顾性综述2004至2018年间接受全膝关节置换术并使用单一模块化钛基板(十字形龙骨)的患者,共纳入2949例全膝关节置换术,至少随访1年,平均随访7年。

主要发现

  • 85例假体(2.8%)翻修,其中46例(1.6%)因无菌性松动。
  • 失败与体重指数、性别、美国麻醉医师协会分级或Charlson合并症指数无关。
  • 体重指数组间失败率无差异(P=0.26),力线不良组(偏离中立机械轴超过3°)失败率无差异(P=0.67)。
  • 年龄与失败相关,失败组患者更年轻(61 vs 65,P<0.01)。

关键数值与推荐

  • 全组假体生存率99%。
  • 翻修率2.8%,无菌性松动翻修率1.6%。

临床怎么用

  • 所有病例均使用高黏度骨水泥。
  • 本研究报告该模块化钛基板在无论体重指数、骨质量或力线不良的患者中均使用单一柄长。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Tibial component aseptic loosening remains problematic in primary total knee arthroplasty (TKA). Influential factors include component design, metallurgy, and cement technique. Additionally, reports advocate for longer tibial stem fixation in high body mass index (BMI) patients. We have utilized a single stem length modular titanium baseplate in patients regardless of BMI, bone quality, or malalignment. We report the survivorship of this implant with focus on the impact of elevated BMI and postoperative malalignment. METHODS: We retrospectively reviewed patients who underwent TKA with a single modular titanium baseplate with a cruciate-shaped keel between 2004 and 2018. In total, 2,949 TKAs with a minimum of 1-year follow-up were included. The mean follow-up was 7 years. The primary outcome was component failure stratified by BMI and postoperative malalignment. High viscosity cement was utilized in all cases. Chi-squared and t-tests were used to compare outcome variables across groups. RESULTS: Eighty-five implants (2.8%) were revised with 46 (1.6%) for aseptic loosening. Failure was not associated with BMI, gender, American Society of Anesthesiologists class, or Charlson Comorbidity Index. There was no difference in failure rate by BMI (P = .26) or by malalignment (outside of 3° from neutral mechanical axis) (P = .67). Age was associated with failure as patients with failed TKAs were younger (61 vs 65, P < .01). CONCLUSION: This design of a specific modular titanium base plate with a cruciate-shaped keel and grit blast surface demonstrated 99% survivorship regardless of patient BMI or malalignment over 7-year follow-up period. Consistent cement technique with high viscosity cement indicates that component design remains an important variable impacting survivorship in TKA.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Stevenson KL, Blackburn BE, Da Silva AZ, et al. High Survivorship of a Modular Titanium Baseplate Independent of Body Mass Index and Malalignment. J Arthroplasty. 2022. PMID: 35246361. doi:10.1016/j.arth.2022.02.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。