文献速递关节外科

磁共振滑膜分类与翻修指征及聚乙烯衬垫损伤相关

Magnetic Resonance Imaging Synovial Classification Is Associated With Revision Indication and Polyethylene Insert Damage.
PubMed 文献 · J Arthroplasty · 2022-02-28

研究纳入接受翻修的全膝关节置换(TKA)患者,术前按盲法将滑膜MRI分类为关节纤维化、局灶性瘢痕、聚合物反应、感染或异常,术中取出聚乙烯衬垫并由2名评估者评分表面损伤。结果示翻修指征与MRI滑膜分类相关(P < .0001),聚合物分类者胫骨衬垫损伤最大(P < .0001),临床指征为无菌性松动者胫骨衬垫损伤最大(P < .0001)。

要点

  • 翻修指征与MRI滑膜分类相关(P < .0001)。
  • MRI分类为聚合物反应者胫骨衬垫损伤最大(P < .0001)。
  • 临床指征为无菌性松动者胫骨衬垫损伤最大(P < .0001)。

核心结论

  • MRI滑膜分级与翻修指征及聚乙烯衬垫损伤强相关。
  • 在无其他并发症的僵硬患者中,MRI可作为确认僵硬诊断的有用辅助手段。

研究设计与样本

  • 接受翻修TKA的僵硬患者术前接受MRI检查,滑膜按盲法分类为关节纤维化、局灶性瘢痕、聚合物反应、感染或异常。
  • 术中取出聚乙烯衬垫,由2名评估者评分总表面损伤。

主要发现

  • 翻修指征与MRI滑膜分类相关(P < .0001),被分类为关节纤维化者中因关节纤维化翻修的比例更大,被分类为聚合物反应者中因无菌性松动翻修的比例更大。
  • MRI滑膜分类为聚合物反应者胫骨衬垫损伤最大(P < .0001)。
  • 因临床指征无菌性松动翻修者胫骨衬垫损伤最大(P < .0001)。

临床怎么用

  • 在无其他并发症的僵硬患者中,作者认为MRI可作为确认僵硬诊断的有用辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with total knee arthroplasty (TKA) stiffness are commonly presumed to have arthrofibrosis though no specific test exists. In patients undergoing revision TKA, we asked the following question: (1) Do patients who are revised for stiffness display a synovial reaction on MRI that is different than patients revised for other reasons? (2) Do these patients have a different magnitude of polyethylene insert damage than patients revised for other reasons? and (3) Is the MRI synovial classification associated with polyethylene insert damage? METHODS: Patients undergoing revision TKA for stiffness had a preoperative MRI performed, and the synovium was classified on MRI in a blinded fashion as arthrofibrosis, focal scarring, polymeric reaction, infection, or abnormal. At surgery, the polyethylene inserts were removed, and graded by 2 reviewers for total surface damage. RESULTS: Revision indication and MRI synovial classification were associated (P < .0001), with a greater proportion of patients assigned an MRI classification of arthrofibrosis revised for arthrofibrosis and a greater proportion of patients assigned a polymeric classification revised for aseptic loosening. Patients assigned an MRI synovial classification of polymeric had the greatest damage to the tibial insert (P < .0001), and patients revised for the clinical indication of aseptic loosening had the greatest damage to the tibial insert (P < .0001). CONCLUSION: Synovial grading on MRI is strongly associated with revision indication and polyethylene insert damage. In patients with stiffness in the absence of another complication, MRI can be a helpful diagnostic adjuvant in confirming the diagnosis of stiffness.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Landy DC, Baral EC, Potter HG, et al. Magnetic Resonance Imaging Synovial Classification Is Associated With Revision Indication and Polyethylene Insert Damage. J Arthroplasty. 2022. PMID: 35240284. doi:10.1016/j.arth.2022.02.086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。