文献速递关节外科

全膝关节置换术中三维术中运动学评估发现后交叉韧带功能障碍患病率增加

Increased Prevalence of Posterior Cruciate Ligament Dysfunction Noted With 3-Dimensional Intraoperative Kinematic Evaluation in Total Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2022-02-18

研究在73例全膝关节置换术中用红外追踪器评估后交叉韧带功能,发现49%的膝关节在间隙平衡时股骨后滚小于60%,提示后交叉韧带功能不全;间隙平衡时后滚与最终后交叉韧带保留假体后滚正相关(r=0.60),并预测术后2年侧位屈膝X线片上的后滚(r=0.50)。

要点

  • 73例全膝关节置换术中,49%的膝关节在间隙平衡时股骨后滚小于60%,提示后交叉韧带功能不全。
  • 间隙平衡时后滚与最终后交叉韧带保留假体后滚正相关(r=0.60,P<.001)。
  • 最终后交叉韧带保留假体后滚预测术后2年侧位屈膝X线片上的后滚(r=0.50,P=.006)。

核心结论

  • 术中功能评估可帮助术者识别股骨后滚与理想膝关节运动学不一致的病例,后稳定可能使这些患者获得更好结果。

研究设计与样本

  • 使用术中红外追踪器监测73例患者的膝关节运动学,评估后交叉韧带完整性。

主要发现

  • 36例膝关节(49%)在间隙平衡时股骨后滚小于60%,提示后交叉韧带功能不全。
  • 间隙平衡时后滚与最终后交叉韧带保留假体后滚正相关(r=0.60,P<.001)。
  • 最终后交叉韧带保留假体后滚预测术后2年侧位屈膝X线片上的后滚(r=0.50,P=.006)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Poor restoration of cruciate-driven kinematics after total knee arthroplasty may result from technical difficulties, but the ligament may also be functionally compromised by the presence of arthritis. We asked whether the function of the posterior cruciate ligament (PCL) could be assessed intraoperatively to predict the quality of the resulting posterior cruciate kinematics. METHODS: PCL integrity was assessed using intraoperative infrared trackers to monitor knee kinematics in 73 patients. Three-dimensional images of the femur and tibia were projected onto a screen, allowing the surgeon to visualize kinematic relationships in real time. We measured femoral rollback (distance of femoral contact as a percentage of antero-posterior tray width) from images captured by the robotic system during initial kinematic assessment, gap balancing, and assessment of the final construct and from lateral flexion radiographs obtained 2 years after surgery. Associations were characterized using Pearson's correlation and graphical methods. RESULTS: Thirty-six knees (49%) showed rollback <60% during gap balancing, indicative of PCL insufficiency. The rollback during gap balancing was positively correlated with that seen in the final cruciate retaining constructs (r = 0.60, P < .001), which in turn predicted rollback 2 years after surgery on lateral flexion X-rays (r = 0.50, P = .006). CONCLUSION: Intraoperative functional evaluations can allow the surgeon to identify cases where rollback is not consistent with desirable knee kinematics, and posterior stabilization may lead to a better outcome for those patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Kinsey TL, Mont MA, Mahoney OM, et al. Increased Prevalence of Posterior Cruciate Ligament Dysfunction Noted With 3-Dimensional Intraoperative Kinematic Evaluation in Total Knee Arthroplasty. J Arthroplasty. 2022. PMID: 35331612. doi:10.1016/j.arth.2022.02.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。