文献速递关节外科创伤骨科

无领锥形滑动柄与有领复合梁柄在失败模式与再手术率上存在差异

Collarless Taper Slip and Collared Composite Beam Stems Differ in Failure Modes and Reoperation Rates.
PubMed 文献 · J Arthroplasty · 2022-02-18

这项回顾性单中心研究分析了2000年至2018年间1306例因骨关节炎行初次混合型全髋关节置换术的患者,比较有领复合梁柄(798例)与无领锥形滑动柄(508例)的生存率。结果显示两组10年假体周围骨折风险无差异,但无领锥形滑动柄组需翻修的假体周围骨折风险增加,而有领复合梁柄组股骨松动和术中骨折风险增加,有领复合梁柄组无翻修和无再手术生存率更高。

要点

  • 10年假体周围骨折风险两组无差异(无领锥形滑动柄9% vs 有领复合梁柄5%;HR 1.4,P=0.47)。
  • 有领复合梁柄组术中需固定的骨折增加(7/798 vs 0/508,P<0.001),无领锥形滑动柄组Vancouver B2型假体周围骨折增加(7/508 vs 0/798,P<0.001)。
  • 有领复合梁柄组股骨松动增加(6/798 vs 0/508,P<0.0001),但10年无翻修生存率(98% vs 91%;HR 4,P=0.001)和无再手术生存率(96% vs 88%;HR 2.5,P=0.002)更高。

核心结论

  • 无领锥形滑动柄组需假体翻修的假体周围骨折风险增加,而有领复合梁柄组股骨假体松动和术中骨折风险增加。
  • 作者认为外科医生在选择假体设计时应意识到不同的失败模式。

研究设计与样本

  • 回顾性单中心研究,纳入2000年至2018年间因骨关节炎行初次混合型全髋关节置换术的1306例患者。
  • 骨水泥柄包括798例有领复合梁柄(EON composite beam,CB)和508例无领锥形滑动柄(Exeter collarless taper slip,CTS),平均年龄77岁。
  • 采用逆处理概率加权模型控制年龄、性别、体重指数、年份和外科医生等危险因素。

主要发现

  • 10年假体周围股骨骨折(PPFX)风险无差异(无领锥形滑动柄9% vs 有领复合梁柄5%;HR 1.4,P=0.47)。
  • 有领复合梁柄组术中需固定的骨折增加(7/798[5例股骨距,2例大转子] vs 0/508,P<0.001)。
  • 无领锥形滑动柄组Vancouver B2型假体周围骨折增加(7/508 vs 0/798,P<0.001)。
  • 有领复合梁柄组股骨松动增加(6/798 vs 0/508,P<0.0001)。
  • 有领复合梁柄组10年无翻修生存率更高(98% vs 91%;HR 4,P=0.001),无再手术生存率更高(96% vs 88%;HR 2.5,P=0.002)。

临床怎么用

  • 作者认为外科医生在选择假体设计时应意识到不同的失败模式。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cemented femoral components are used in older patients based on lower risk of periprosthetic fracture and implant loosening. This study reports the survivorship free of periprosthetic femoral fracture (PPFX), femoral loosening, all-cause revision, and reoperation between 2 philosophies of cemented stems. METHODS: In total, 1,306 primary hybrid total hip arthroplasties were performed for osteoarthritis between 2000 and 2018 in a retrospective single center study. Cemented stems included 798 EON composite beam (CB) and 508 Exeter collarless taper slip (CTS) stems. Mean age was 77 years. An inverse treated probability weighted model was utilized to control for risk factors including age, gender, body mass index, year, and surgeon. RESULTS: There was no difference in risk of PPFX at 10 years (CTS 9% vs CB 5%; hazard ratio [HR] 1.4, P = .47). There was an increased risk of intraoperative fractures requiring fixation in the CB cohort (7/798 [5 calcar, 2 greater trochanter] vs 0/508, P < .001), while there was an increased risk of Vancouver B2 PPFX in the CTS cohort (7/508 vs 0/798; P < 001). There was a higher risk of femoral loosening in the CB cohort (6/798 vs 0/508; P < .0001). Higher survivorship free of revision (98% vs 91%; HR 4, P = .001) and free of reoperation (96% vs 88%; HR 2.5, P = .002) was seen at 10 years in the CB cohort. CONCLUSION: The risk of PPFX requiring implant revision was increased in the CTS cohort, while there was an increased risk of femoral component loosening and intraoperative fractures seen in the CB cohort. Surgeons should be aware of the different failure modes when choosing implant design for their patient.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Rames RD, Smartt AA, Abdel MP, et al. Collarless Taper Slip and Collared Composite Beam Stems Differ in Failure Modes and Reoperation Rates. J Arthroplasty. 2022. PMID: 35279340. doi:10.1016/j.arth.2022.02.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。