使用薄聚乙烯内衬与大股骨头的初次全髋关节置换术:至少5年随访
回顾性分析58例使用薄聚乙烯内衬(X3聚乙烯,Stryker)和大股骨头(36 mm或更大)的初次全髋关节置换术,至少随访5年。44例患者纳入最终分析,平均随访8.5年,以薄聚乙烯内衬失败为终点的生存率为100%,无内衬骨折或骨溶解病例。
要点
- 44例初次全髋关节置换术使用薄聚乙烯内衬和大股骨头(≥36 mm),平均随访8.5年。
- 以薄聚乙烯内衬失败为终点的生存率为100%,无内衬骨折或骨溶解。
- 共4例翻修:无菌性松动2例、假体周围感染1例、复发性脱位1例。
核心结论
- 在小髋臼杯中联合使用大股骨头与薄聚乙烯内衬,平均8.5年随访结果优良,无内衬骨折或骨溶解病例。
研究设计与样本
- 回顾性综述,纳入来自同一制造商的薄聚乙烯内衬(X3聚乙烯,Stryker,马瓦,新泽西州)和大股骨头(36 mm或更大)的58例初次全髋关节置换术,至少随访5年。
- 3例患者死亡,11例失访,最终44例患者纳入分析。
- 所有患者均为女性,平均年龄65.7岁(范围26-85),平均体重指数29.9(范围19.6-45.4)。
- 平均随访时间8.5年(范围5.1-11.3)。
主要发现
- 共4例翻修:无菌性松动2例、假体周围感染1例、复发性脱位1例。
- 平均HOOS-Jr评分94.3/100,FJS-12评分92.9/100,Likert满意度评分4.69/5.00,94%的患者报告满意或非常满意。
- 平均8.5年影像学分析显示假体固定良好,无进展性放射透亮线、骨溶解或聚乙烯内衬失败的证据。
- 以薄聚乙烯内衬失败为终点的生存率在平均8.5年时为100%。
局限性
- 本研究为回顾性综述。
- 58例中3例死亡、11例失访,最终仅44例患者纳入分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Large femoral head sizes are commonly used in total hip arthroplasty (THA) to minimize the risk of instability. With small acetabular cup-size, large femoral head diameter often results in the use of thin polyethylene liners. The purpose of this study was to evaluate clinical and radiographic results of large femoral heads against thin polyethylene liners with minimum 5-year follow-up. METHODS: This was a retrospective review identifying 58 primary THAs utilizing thin polyethylene inserts from one manufacturer (X3 polyethylene, Stryker, Mahwah, NJ) and large femoral heads (36 mm or greater) with minimum 5-year follow-up. A total of 3 patients were deceased and 11 lost to follow-up, leaving 44 patients for review. All patients were female with mean age 65.7 (range 26-85) and mean body mass index (BMI) 29.9 (range 19.6-45.4). Average length of follow-up was 8.5 years (range 5.1-11.3). Outcome measures included survivorship, complications, PROMs and radiographic analysis. RESULTS: There were four revisions: two aseptic loosening, one prosthetic joint infection, and one recurrent dislocation. Average HOOS-Jr, FJS-12, and patient satisfaction using Likert score was 94.3/100, 92.9/100, and 4.69/5.00, respectively, with 94% of patients reporting being satisfied or very satisfied. Radiographic analysis at average of 8.5 years demonstrated well-fixed implants without evidence of progressive radiolucent lines, osteolysis, or failure of the polyethylene liner. Survivorship using failure of the thin polyethylene liner as the endpoint was 100% at an average of 8.5 years. CONCLUSION: Thin polyethylene liners used with large femoral head sizes in small acetabular cups demonstrated excellent results at average 8.5-year follow-up with no cases of liner fracture or osteolysis.
引用
- Hagman DS, Smith AF, Presley TL, et al. Primary THA Using Thin Polyethylene Liners and Large Femoral Heads: A Minimum 5-Year Follow-Up. J Arthroplasty. 2022. PMID: 35276279. doi:10.1016/j.arth.2022.02.117
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。