文献速递关节外科

将旋转铰链假体与固定良好的股骨套筒配合用于全膝关节翻修术

Revision Total Knee Arthroplasty With a Rotating-Hinge Prosthesis Mated to a Well-Fixed Femoral Sleeve.
PubMed 文献 · J Arthroplasty · 2022-02-26

回顾性比较60例S-ROM Noiles旋转铰链全膝关节翻修术患者,9例(15%)将新股骨假体与既往翻修留下的固定良好套筒配合,51例(85%)使用新套筒。固定良好套筒组再翻修2例(22%),新套筒组再翻修9例(18%);所有患者平均膝关节协会评分从39改善至73。作者认为短期内在固定良好套筒上配合S-ROM股骨是安全、简单且持久的选择,未观察到新的失败模式。

要点

  • 固定良好套筒组再翻修2例(22%),新套筒组再翻修9例(18%)。
  • 所有患者平均膝关节协会评分从39改善至73。
  • 未观察到包括锥形连接处在内的独特失败模式。

核心结论

  • 作者认为,将S-ROM股骨与既往翻修留下的固定良好套筒配合,在短期内是安全、简单且持久的选择,可避免与取出固定良好套筒相关的并发症。
  • 未观察到新的失败模式。

研究设计与样本

  • 回顾性研究,纳入1998年至2019年植入S-ROM Noiles旋转铰链全膝关节置换术的60例患者,其中9例(15%)股骨假体与固定良好套筒配合,51例(85%)使用新套筒。
  • 平均年龄68岁,女性占68%,平均体重指数33 kg/m2,平均随访5年。

主要发现

  • 固定良好套筒组再翻修2例(22%):1例感染,1例股骨和胫骨无菌性松动。
  • 新套筒组再翻修9例(18%):7例感染,2例胫骨无菌性松动。
  • 所有患者平均膝关节协会评分从39改善至73。
  • 影像学上,除新套筒组1例股骨松动外,所有假体均固定良好。

局限性

  • 证据等级为IV级(回顾性),治疗性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Some knee systems have the unique capability to mate a new hinged femoral component to a well-fixed metaphyseal sleeve from a prior revision. We compared survivorship, radiographs, and clinical outcomes of a rotating-hinge total knee arthroplasty mated to a new metaphyseal sleeve vs a well-fixed sleeve. METHODS: Sixty patients with an S-ROM Noiles (DePuy Synthes, Warsaw, IN) rotating-hinge total knee arthroplasty implanted from 1998 to 2019 were retrospectively reviewed. Nine patients (15%) had the femoral component mated to a well-fixed sleeve and 51 patients (85%) had a new sleeve. Mean age was 68 years, 68% were female, and mean body mass index was 33 kg/m2. The incidences of re-revision and reoperation were calculated, Knee Society Scores were measured, and radiographs were reviewed. Mean follow-up was 5 years. RESULTS: There were 2 re-revisions (22%) in patients with a well-fixed sleeve: 1 for infection and 1 for aseptic loosening of the femur and tibia. There were no unique failures including the taper junction. Nine patients (18%) with a new sleeve were re-revised: 7 for infection and 2 for tibial aseptic loosening. The mean Knee Society Score for all patients improved from 39 to 73. Radiographically, all components were well fixed except for one loose femur in a patient with a new sleeve. CONCLUSION: Mating an S-ROM femur to a well-fixed sleeve from a prior revision is a safe, simple, and durable option in the short term that prevents morbidity associated with removal of a well-fixed sleeve. No new modes of failure were observed. LEVEL OF EVIDENCE: IV (retrospective), Therapeutic.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Hannon CP, Stuart MB, Abdel MP, et al. Revision Total Knee Arthroplasty With a Rotating-Hinge Prosthesis Mated to a Well-Fixed Femoral Sleeve. J Arthroplasty. 2022. PMID: 35227812. doi:10.1016/j.arth.2022.02.075

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。