文献速递关节外科创伤骨科

在前路全髋关节置换术中使用短的非骨水泥股骨柄时能否预测骨折

Can We Predict Fracture When Using a Short Cementless Femoral Stem in the Anterior Approach?
PubMed 文献 · J Arthroplasty · 2022-03-18

这项单中心、多术者回顾性病例对照匹配研究分析了1145例前路初次全髋关节置换术中使用短的非骨水泥股骨柄的病例,识别出39例假体周围骨折(3.4%),并与78例无骨折对照匹配。放射学分析显示骨折组股骨管喇叭形指数(CFI)和股骨距-股骨距比值(CCR)更高、髂骨-坐骨比值(IIR)更高、髓腔填充百分比更低;CFI阈值3.17可预测骨折(敏感性84.6%/特异性75.6%),当CFI>3.17且IIR>3时骨折风险高29倍(OR: 29.2,95%CI: 9.5-89.9,P<.001)。作者认为患者特异性解剖参数是骨折风险的重要预测因素,仔细的放射学分析有助于识别短柄早期骨折风险并考虑替代柄选项。

要点

  • 短的非骨水泥股骨柄前路全髋关节置换术中假体周围骨折率为3.4%(39/1145)。
  • CFI阈值3.17预测骨折的敏感性84.6%、特异性75.6%。
  • CFI>3.17且IIR>3时骨折风险高29倍(OR: 29.2,95%CI: 9.5-89.9,P<.001)。

核心结论

  • 患者特异性解剖参数是骨折风险的重要预测因素。
  • 仔细的放射学分析有助于识别使用短柄时早期骨折风险,应考虑替代柄选项。

研究设计与样本

  • 单中心、多术者回顾性病例对照匹配研究,纳入1145例前路初次全髋关节置换术中使用短的非骨水泥股骨柄的病例,识别39例假体周围骨折(3.4%),并与78例无骨折对照进行匹配。

主要发现

  • 骨折组CFI为3.7±0.6 vs 对照组2.9±0.4(P<.001)。
  • 骨折组CCR为0.5±0.1 vs 对照组0.4±0.1(P=.006)。
  • 骨折组平均IIR为3.3±0.6 vs 对照组3.0±0.5(P<.001)。
  • 骨折组髓腔填充百分比为82.8±7.6 vs 对照组86.7±6.8(P=.007)。
  • 多因素和ROC分析显示CFI阈值3.17预测骨折的敏感性84.6%、特异性75.6%;当CFI>3.17且IIR>3时骨折风险高29倍(OR: 29.2,95%CI: 9.5-89.9,P<.001)。

关键数值与推荐

  • CFI阈值3.17预测骨折的敏感性84.6%、特异性75.6%。
  • CFI>3.17且IIR>3时骨折风险的OR为29.2(95%CI: 9.5-89.9,P<.001)。

临床怎么用

  • 作者认为,仔细的放射学分析有助于识别使用短柄时早期骨折风险,应考虑替代柄选项。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Short cementless femoral stems may allow for easier insertion with less dissection. The use of short stems with the anterior approach (AA) may be associated with a considerable perioperative fracture risk. Our aim was to evaluate whether patient-specific femoral and pelvic morphology and surgical technique, influence the perioperative fracture risk. Furthermore, we sought to describe important anatomical thresholds alerting surgeons. METHODS: A single-center, multi-surgeon retrospective, case-control matched study was performed. Thirty nine periprosthetic fractures (3.4%) in 1,145 primary AA THAs using short cementless stems were identified. These were matched with 78 THA nonfracture controls for factors known to increase the fracture risk. A radiographic analysis using validated software measured femoral (canal flare index [CFI], morphological cortical index [MCI], and calcar-calcar ratio [CCR]) and pelvic (Ilium-ischial ratio [IIR], ilium overhang, and anterior superior iliac spine [ASIS] to greater trochanter distance) morphologies and surgical techniques (% canal fill). A multivariate and Receiver-Operator Curve (ROC) analysis was used to identify fracture predictors. RESULTS: CFI (3.7 ± 0.6 vs 2.9 ± 0.4, P < .001) and CCR (0.5 ± 0.1 vs 0.4 ± 0.1, P = .006) differed. The mean IIR was higher in fracture cases (3.3 ± 0.6 vs 3.0 ± 0.5, P < .001). Percent canal fill was reduced in fracture cases (82.8 ± 7.6 vs 86.7 ± 6.8, P = .007). Multivariate and ROC analyses revealed a threshold CFI of 3.17 which was predictive of fracture (sensitivity: 84.6%/specificity: 75.6%). The fracture risk was 29 times higher when patients had CFI >3.17 and II ratio >3 (OR: 29.2 95% CI: 9.5-89.9, P < .001). CONCLUSION: Patient-specific anatomical parameters are important predictors of a fracture-risk. A careful radiographic analysis would help identify those at a risk of early fracture using short stems, and alternative stem options should be considered.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. McGoldrick NP, Cochran MJ, Biniam B, et al. Can We Predict Fracture When Using a Short Cementless Femoral Stem in the Anterior Approach? J Arthroplasty. 2022. PMID: 35314289. doi:10.1016/j.arth.2022.03.054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。