L4水平小梁CT衰减测量用于预测退变性腰椎融合术后螺钉松动:需考虑融合节段数和术后矢状面平衡
该回顾性研究纳入478例腰椎融合手术患者,分析L4小梁感兴趣区CT衰减值与螺钉松动的关联,并按融合节段数和术后C7-S1矢状垂直轴分组确定预测螺钉松动的最佳截断值。结果显示融合节段数、术后C7-S1矢状垂直轴和L4小梁感兴趣区CT衰减值均与螺钉松动独立相关;不同融合节段数和矢状面平衡条件下最佳截断值不同。作者认为结合融合节段数和矢状面平衡的L4小梁感兴趣区CT衰减值可准确预测螺钉松动。
要点
- 融合节段数、术后C7-S1矢状垂直轴和L4小梁感兴趣区CT衰减值与螺钉松动独立相关。
- 单节段融合且C7-S1矢状垂直轴<36.9 mm者,L4截断值为106.5 HU。
- 三节段融合且C7-S1矢状垂直轴<36.9 mm者截断值为159.0 HU,≥36.9 mm者为191.0 HU。
核心结论
- 考虑融合节段数和矢状面平衡的L4小梁感兴趣区CT衰减值是一种可准确预测螺钉松动的测量方法。
- 脊柱外科医生应在术前了解L4小梁感兴趣区衰减值,以提高骨质疏松患者腰椎手术的融合率并减少器械相关并发症。
研究设计与样本
- 回顾性研究,纳入478例患者并分析螺钉松动相关因素。
- 评估L4小梁感兴趣区CT衰减值与螺钉松动的关联,并确定预测螺钉松动的最佳截断值。
主要发现
- 融合节段数、术后C7-S1矢状垂直轴和L4小梁感兴趣区CT衰减值均与螺钉松动独立相关。
- 单节段融合且C7-S1矢状垂直轴<36.9 mm的患者中,L4小梁感兴趣区CT衰减值预测螺钉松动的最佳截断点为106.5 HU。
- L4小梁感兴趣区衰减值在双节段融合前不变。
- 三节段融合且C7-S1矢状垂直轴<36.9 mm的患者中,最佳截断点为159.0 HU。
- 三节段融合且C7-S1矢状垂直轴≥36.9 mm的患者中,最佳截断点为191.0 HU。
关键数值与推荐
- 单节段融合且C7-S1矢状垂直轴<36.9 mm:L4小梁感兴趣区CT衰减值最佳截断点106.5 HU。
- 三节段融合且C7-S1矢状垂直轴<36.9 mm:L4小梁感兴趣区CT衰减值最佳截断点159.0 HU。
- 三节段融合且C7-S1矢状垂直轴≥36.9 mm:L4小梁感兴趣区CT衰减值最佳截断点191.0 HU。
临床怎么用
- 脊柱外科医生应在术前了解L4小梁感兴趣区衰减值,以提高骨质疏松患者腰椎手术融合率并减少器械相关并发症。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective study. OBJECTIVE: To evaluate the absolute value of L4 trabecular region-of-interest (t-ROI) computed tomography (CT) attenuation, which can predict pedicle screw loosening, and determine the changes in value according to number of fused levels and sagittal balance in patients undergoing lumbar fusion surgery. SUMMARY OF BACKGROUND DATA: Although osteoporosis was not diagnosed in spinal dual x-ray absorptiometry preoperatively, we encountered several cases of screw loosening within 1 year of lumbar fusion surgery. METHODS: We enrolled 478 patients and analyzed factors related to screw loosening. We evaluated the association between L4 t-ROI CT attenuation and screw loosening and determined the best cutoff value of t L4 t-ROI CT attenuation for predicting screw loosening. RESULTS: The number of fused levels, postoperative C7-S1 sagittal vertical axis (SVA), and L4 t-ROI CT attenuation were independently correlated with screw loosening. According to number of fused level and postoperative C7-T1 SVA (≥36.9 mm or <36.9 mm), in patients with one-level fusion and C7-S1 SVA less than 36.9 mm, the optimal cutoff point of the L4 t-ROI CT attenuation predicting screw loosening was 106.5 Hounsfield unit (HU). L4 t-ROI attenuation did not change until two-level fusions. In patients with three-level fusions and C7-S1 SVA less than 36.9 mm, the optimal cutoff point of the L4 t-ROI CT attenuation predicting screw loosening was 159.0 HU. The optimal cutoff point of L4 t-ROI CT attenuation in patients with three-level fusions and C7-S1 SVA more than or equal to 36.9 mm was 191.0 HU. CONCLUSION: L4 t-ROI CT attenuation value considering number of fused levels and sagittal balance is an accurate measurement method to predict screw loosening. Spine surgeons should be aware of the L4 t-ROI attenuation before surgery to improve the fusion rate and reduce instrument-related complications of lumbar spine surgery in osteoporotic patients. LEVEL OF EVIDENCE: 3.
引用
- Shin HK, Koo HW, Kim KH, et al. The Usefulness of Trabecular CT Attenuation Measurement at L4 Level to Predict Screw Loosening After Degenerative Lumbar Fusion Surgery: Consider Number of Fused Levels and Postoperative Sagittal Balance. Spine (Phila Pa 1976). 2022. PMID: 35102120. doi:10.1097/BRS.0000000000004330