文献速递运动医学关节外科

前交叉韧带重建中关节镜下Ramp损伤修复的生存率与危险因素分析

Survival and Risk Factor Analysis of Arthroscopic Ramp Lesion Repair During Anterior Cruciate Ligament Reconstruction.
PubMed 文献 · Am J Sports Med · 2022-01-31

该病例对照研究(证据等级3级)回顾性评估2015年11月至2018年1月因前交叉韧带损伤接受关节镜下Ramp损伤修复的患者,248处损伤中18处(7.3%)失败;全内缝合装置修复失败率为21.1%,缝合钩修复为4.3%(P=0.003);Cox模型中唯一失败危险因素为修复方式,全内装置风险为缝合钩修复的5倍以上(HR 5.1,95%CI 1.8-14.5)。

要点

  • 248处Ramp损伤中18处(7.3%)修复失败,失败以二次关节镜确认。
  • 全内装置修复失败率21.1%,高于缝合钩修复的4.3%(P=0.003)。
  • Cox模型中唯一失败危险因素为修复方式,全内装置HR 5.1(95%CI 1.8-14.5)。

核心结论

  • 关节镜下全内技术修复Ramp损伤似乎是安全有效的,修复半月板愈合优良,总体失败率为7.3%。
  • 缝合方式与Ramp损伤修复失败相关,全内装置的风险显著高于缝合钩修复缝线。

研究设计与样本

  • 病例对照研究,证据等级3级。
  • 回顾性评估2015年11月至2018年1月期间所有接受关节镜下Ramp损伤修复联合前交叉韧带重建的患者。
  • 研究参数包括人口学资料、临床病史、临床发现(国际膝关节文献委员会评分、并发症、从受伤到手术的时间、侧侧松弛度、轴移试验)及手术发现(亚型、手术处理、缝线类型与数量)。
  • Ramp损伤修复失败以二次关节镜确认。

主要发现

  • 共分析248处损伤,记录18处(7.3%)失败。
  • 全内装置处理的修复中失败率为21.1%,缝合钩缝合处理的失败率为4.3%(P=0.003)。
  • Cox模型纳入的6个因素中,唯一被确定为失败危险因素的是修复方式(P=0.003),全内装置的风险为缝合钩修复的5倍以上(对应风险比5.1,95%CI 1.8-14.5)。
  • 未记录到其他涉及手术技术或装置的并发症。

关键数值与推荐

  • Ramp损伤修复失败率:248处损伤中18处(7.3%)。
  • 全内装置修复失败率21.1%,缝合钩修复失败率4.3%(P=0.003)。
  • 全内装置相对缝合钩修复的失败风险比HR 5.1(95%CI 1.8-14.5)。

临床怎么用

  • 作者认为关节镜下全内技术修复Ramp损伤似乎是安全有效的,总体失败率7.3%。
  • 作者指出缝合方式与修复失败相关,全内装置风险显著高于缝合钩修复缝线。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is a lack of research on the management of ramp lesions associated with anterior cruciate ligament (ACL) injuries. Furthermore, there has been no report of the risk factors for failure of ramp lesion sutures, linked to either the technique used (all-inside suture implant vs suture hook through a posteromedial portal) or the type of lesion (location in the red zone or meniscocapsular junction, longitudinal extension, partial- or full-thickness tear). PURPOSE: To evaluate the results of arthroscopic repair of ramp lesions and determine the risk factors associated with ramp lesion repair failure, with special focus on their subtype and the suture technique. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: All patients who underwent arthroscopic ramp lesion repair in association with ACL reconstruction between November 2015 and January 2018 were evaluated retrospectively. The following parameters were studied: demographics; clinical history; clinical findings including International Knee Documentation Committee score, complications, time from injury to surgery, side-to-side laxity, and pivot shift; and surgical findings including subtype, surgical management, and type and number of sutures. Failure of the ramp lesion repair was defined at secondary arthroscopy. RESULTS: Among the 248 lesions analyzed, 18 (7.3%) failures were documented. The failures occurred in 21.1% of repairs managed with the all-inside device versus 4.3% of sutures managed with the suture hook (P = .003). Among the 6 factors included in the Cox model, the only one identified as a risk factor for failure was the type of repair (P = .003), with a risk for the all-inside device that was >5-fold higher than that for the suture hook repair (corresponding hazard ratio, 5.1 [95% CI, 1.8-14.5]). No other complications involving the surgical technique or device were registered. CONCLUSION: An arthroscopic all-inside technique of meniscal repair of ramp lesions appeared to be safe and effective. It provided excellent healing of the repaired meniscus, with an overall failure rate of 7.3%. The type of suture was associated with failure of the ramp lesion repair, with a significantly higher risk with the all-inside device than with suture hook repair sutures.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Thaunat M, Foissey C, Ingale P, et al. Survival and Risk Factor Analysis of Arthroscopic Ramp Lesion Repair During Anterior Cruciate Ligament Reconstruction. Am J Sports Med. 2022. PMID: 35099318. doi:10.1177/03635465211068524

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。