文献速递关节外科

应用数学算法将矢状面功能安全区转换为冠状面:Lewinnek安全区失效的原因

Conversion of the Sagittal Functional Safe Zone to the Coronal Plane Using a Mathematical Algorithm: The Reason for Failure of the Lewinnek Safe Zone.
PubMed 文献 · J Bone Joint Surg Am · 2022-02-09

本研究通过骨盆模型和100例机器人辅助全髋关节置换术患者影像,验证了将前倾角与影像学前倾、外展及骨盆倾斜相关联的数学算法,并将矢状面安全区转换为冠状面功能安全区,发现低骨盆活动度或低骨盆入射角患者的功能安全区显著更小,且不存在适用于所有患者的通用杯取向。

要点

  • 算法在随访时骨盆倾斜条件下准确,模型和患者影像的平均绝对误差分别为1.5°和2.8°。
  • 术前预测前倾角的平均绝对误差为9.0°。
  • 低骨盆活动度或低骨盆入射角患者的冠状面功能安全区及其与Lewinnek安全区的交集显著更小(p < 0.017)。

核心结论

  • 全髋关节置换术中杯的目标取向应个体化。
  • 经验证的算法可作为基于功能安全区对杯前倾角进行患者特异性优化的定量工具。
  • Lewinnek安全区失效是因为它无法预测杯的功能性取向,通用安全区的概念应被放弃并由患者特异性手术目标替代。

研究设计与样本

  • 研究分两阶段:第一阶段设计骨盆模型模拟不同骨盆倾斜值,使用机器人辅助技术植入髋臼杯并以EOS成像系统扫描;第二阶段纳入2019年4月至2019年12月接受机器人辅助全髋关节置换术的100例患者,记录术前和术后12个月随访的EOS影像。
  • 在侧位X线片上测量前倾角作为参考,与计算的前倾角比较以评估算法准确性;采用线性回归探索冠状面功能安全区大小与骨盆活动度和骨盆入射角的关系;计算患者冠状面功能安全区的交集以寻找通用杯取向。

主要发现

  • 基于模型研究和患者随访时骨盆倾斜的影像,算法准确,平均绝对误差分别为1.5°(95%置信区间宽度2.2°)和2.8°(95%置信区间宽度3.0°)。
  • 术前预测的前倾角平均绝对误差为9.0°(95%置信区间宽度10.5°)。
  • 在骨盆活动度或骨盆入射角较低的患者亚组中,冠状面功能安全区及其与Lewinnek安全区的交集大小显著更小(p < 0.017)。
  • 不存在满足所有患者或任何骨盆活动度或骨盆入射角亚组的标准的通用杯取向。

关键数值与推荐

  • 模型研究中算法平均绝对误差为1.5°(95%置信区间宽度2.2°)。
  • 患者随访时骨盆倾斜条件下算法平均绝对误差为2.8°(95%置信区间宽度3.0°)。
  • 术前预测前倾角平均绝对误差为9.0°(95%置信区间宽度10.5°)。
  • 低骨盆活动度或低骨盆入射角亚组的冠状面功能安全区及其与Lewinnek安全区交集显著更小(p < 0.017)。

临床怎么用

  • 作者认为全髋关节置换术中杯的目标取向应个体化。
  • 作者认为经验证的算法可作为基于功能安全区对杯前倾角进行患者特异性优化的定量工具。
  • 作者认为Lewinnek安全区失效是因为它无法预测杯的功能性取向,通用安全区的概念应被放弃并由患者特异性手术目标替代。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ante-inclination (AI) of the cup is a key component of the combined sagittal index (CSI) for predicting joint stability after total hip arthroplasty (THA). We aimed to (1) validate a mathematical algorithm relating AI to radiographic anteversion (RA), radiographic inclination (RI), and pelvic tilt (PT); (2) convert the AI criterion of the CSI into the coronal functional safe zone (CFSZ) and explore the influences of standing-to-sitting pelvic motion (PM) and pelvic incidence (PI) on the CFSZ; and (3) attempt to locate a universal cup orientation that always fulfills the AI criterion of the CSI for all patients. METHODS: In the first phase, a phantom pelvis was designed to simulate a range of PT values, and an acetabular cup was implanted with different RA, RI, and PT settings using a robot-assisted technique and scanned using the EOS imaging system. The second phase involved patient radiographs. We enrolled 100 patients who underwent robot-assisted THA from April 2019 to December 2019, and EOS images before THA and at the 12-month follow-up were recorded. The AI was measured on a lateral radiograph; this angle was used as the reference and compared with the calculated AI to assess the accuracy of the algorithm. Linear regression was conducted to explore the relationship between the size of the CFSZ and the values of PM and PI. We calculated the intersection of the CFSZs of the patients to find a universal cup orientation (RA and RI) for the CSI. RESULTS: The algorithm was accurate according to both the phantom study and patient radiographs using PT at the time of follow-up, with mean absolute errors (MAEs) of 1.5° (width of 95% confidence interval [CI], 2.2°) and 2.8° (width of 95% CI, 3.0°), respectively. However, the preoperatively predicted AI had an MAE of 9.0° (width of 95% CI, 10.5°). In patient subgroups with lower PM or PI, the sizes of the CFSZ and of its intersection with the Lewinnek safe zone were significantly smaller (p < 0.017). No universal cup orientation existed to fulfill the CSI criteria for all patients or for any of the PM or PI subgroups. CONCLUSIONS: The target orientation for the cup in THA should be individualized. Our validated algorithm may serve as a quantitative tool for the patient-specific optimization of cup AI on the basis of the functional safe zone. CLINICAL RELEVANCE: The Lewinnek safe zone fails because it cannot predict the functional orientation of the cup. The concept of a universal safe zone of cup orientation should be abandoned and replaced by a patient-specific surgical target.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Tang H, Zhao Y, Wang S, et al. Conversion of the Sagittal Functional Safe Zone to the Coronal Plane Using a Mathematical Algorithm: The Reason for Failure of the Lewinnek Safe Zone. J Bone Joint Surg Am. 2022. PMID: 35139043. doi:10.2106/JBJS.21.00840

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。