文献速递关节外科

在当代血液管理下,计算机辅助全膝关节置换术中避免股骨髓腔操作与常规技术相比在失血量和输血率方面差异极小

Avoiding Femoral Canal Instrumentation in Computer-Assisted Total Knee Arthroplasty With Contemporary Blood Management Had Minimal Differences in Blood Loss and Transfusion Rates Compared to Conventional Techniques.
PubMed 文献 · J Arthroplasty · 2022-02-24

该回顾性队列纳入2016至2020年单中心14,890例单侧初次全膝关节置换术,其中4,165例(28%)使用加速度计或机器人计算机辅助。多因素回归显示计算机导航对输血无保护作用(OR 1.04,P=0.73),线性回归显示每例减少失血19 mL(P<0.0001)。

要点

  • 计算机导航未降低输血率(OR 1.04,P=0.73)。
  • 计算机导航每例减少计算总失血量19 mL(P<0.0001)。
  • 术前血红蛋白<10 g/dL(OR 10.5)和引流管使用(OR 2.25)是输血最强危险因素。

核心结论

  • 在当代全膝关节置换患者中,避免股骨髓腔操作的计算机辅助手术与输血率降低无关,总体失血量差异极小。

研究设计与样本

  • 回顾性队列分析,纳入2016至2020年单中心14,890例单侧初次全膝关节置换术患者,其中4,165例(28%)使用加速度计或机器人计算机辅助,4,860例(32%)使用引流管。

主要发现

  • 542例(3.6%)接受输血,血红蛋白平均变化2.1 g/dL(标准差0.91),平均计算总失血量310 mL(标准差154)。
  • 多因素回归模型中计算机导航对输血无保护作用(OR 1.04,P=0.73)。
  • 术前血红蛋白<10 g/dL(OR 10.5,P<0.0001)和引流管使用(OR 2.25,P<0.0001)是输血的最显著危险因素。
  • 线性回归模型中计算机导航每例减少失血量19 mL(标准差2.94,P<0.0001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Computer-assisted surgery that does not utilize femoral canal instrumentation is theorized to have less blood loss. However, there is a paucity of data on this, particularly in the era of tranexamic acid use. We sought to analyze the association of computer navigation with total calculated blood loss and transfusion rate in patients undergoing primary total knee arthroplasty (TKA). METHODS: We identified 14,890 patients who underwent unilateral primary TKA at a single institution from 2016 to 2020. Computer-assisted surgery in the form of an accelerometer or robotics was utilized in 4,165 TKAs (28%). Drains were utilized in 4,860 TKAs (32%). We used multivariate logistic regression analysis to determine if computer navigation reduced the rate of blood transfusion and linear regression analysis to determine the impact of computer navigation on blood loss. RESULTS: In total, 542 patients (3.6%) underwent a transfusion. The average change in hemoglobin (Hgb) was 2.1 g/dL (standard deviation [SD] 0.91) and average total calculated blood loss was 310 mL (SD = 154). In a multivariate regression model, computer navigation was not protective of transfusion (odds ratio [OR] 1.04, P = .73). Preoperative Hgb <10 (OR 10.5, P < .0001) and drain use (OR 2.25, P < .0001) were the most significant risk factors for transfusion. In a linear regression model, computer navigation reduced blood loss by 19 mL (SD 2.94, P < .0001) per case. CONCLUSION: In this large retrospective cohort analysis of contemporary TKA patients, computer-assisted surgery that eliminates intramedullary femoral canal instrumentation during primary TKA was not associated with reduced transfusion rates and had minimal differences in overall blood loss.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Puri S, Chiu YF, Boettner F, et al. Avoiding Femoral Canal Instrumentation in Computer-Assisted Total Knee Arthroplasty With Contemporary Blood Management Had Minimal Differences in Blood Loss and Transfusion Rates Compared to Conventional Techniques. J Arthroplasty. 2022. PMID: 35218911. doi:10.1016/j.arth.2022.02.072

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。