双枢轴适形聚乙烯全膝关节置换术中后交叉韧带松解对运动学与结局的影响
前瞻性纳入40例使用不对称超适形垫片行初次全膝关节置换术的患者,术前及术后4个月进行三维步态分析。后交叉韧带完全松解组最大股骨前后平移及最大胫骨内旋更大,且膝关节损伤与骨关节炎结局评分(KOOS-JR)更低。保留或部分滴定松解后交叉韧带似乎可减少不良运动学并优化患者报告结局。
要点
- 后交叉韧带完全松解占52.5%(21/40),松解组最大股骨前后平移9.8 vs 5.5 mm(P=0.053)。
- 后交叉韧带松解组最大胫骨内旋-6.2° vs -3.0°(P=0.040),KOOS-JR中位数70.7 vs 76.3(P=0.031)。
- 最大股骨前后平移越大与KOOS-JR越低相关(rho=-0.596,P=0.012)。
核心结论
- 使用该不对称超适形垫片行全膝关节置换术时,保留或部分滴定松解后交叉韧带(而非完全松解)似乎可最小化有害的股骨前移和胫骨内旋,并与优化的患者报告结局相关。
研究设计与样本
- 前瞻性纳入40例使用不对称超适形垫片行全膝关节置换术的患者,术前及术后4个月采用红外运动捕捉进行三维步态分析,分析膝关节运动学数据与后交叉韧带处置和患者报告结局的相关性。证据等级II。
主要发现
- 后交叉韧带完全松解占52.5%(21/40)。
- 最大股骨前后平移越大与KOOS-JR越低相关(rho=-0.596,P=0.012),与平地行走时KSS疼痛越大相关(rho=0.411,P=0.101),与爬楼梯时KSS疼痛越大相关(rho=0.469,P=0.058),均为4个月随访。
- 后交叉韧带松解组最大股骨前后平移9.8 vs 5.5 mm(P=0.053),最大胫骨内旋-6.2° vs -3.0°(P=0.040)。
- 后交叉韧带松解组KOOS-JR中位数70.7 vs 76.3(P=0.031),报告膝关节「有时或总是」感觉正常者比例81.8% vs 92.3%(P=0.576)。
临床怎么用
- 作者认为,使用该不对称超适形垫片行全膝关节置换术时,保留或部分滴定松解后交叉韧带(而非完全松解)似乎可最小化有害的股骨前移和胫骨内旋,并与优化的患者报告结局相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ultracongruent bearings are increasingly utilized in total knee arthroplasty (TKA); however, implications of surgical technique on knee kinematics and outcomes with these bearings are not well understood. This study's purpose was to evaluate the relationship of 3-dimensional knee kinematics and patient-reported outcome measures (PROMs) in a dual-pivot congruent bearing TKA with and without posterior cruciate ligament (PCL) release. METHODS: Forty patients undergoing TKA with an asymmetric ultracongruent bearing were prospectively enrolled for gait analysis preoperatively and 4 months postoperatively. Three-dimensional gait analysis was performed utilizing infrared motion capture. Knee kinematic data and PCL disposition were analyzed for correlations with PROMs. RESULTS: The PCL was fully released in 52.5% (21/40) of cases. Greater maximum anteroposterior femoral translation correlated with lower Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (rho = -0.596, P = .012), greater Knee Society Score pain with level walking (rho = 0.411, P = .101), and greater Knee Society Score pain while climbing stairs (rho = 0.469, P = .058) at 4-month follow-up. The PCL-release group was associated with greater maximum femoral anteroposterior translation (9.8 vs 5.5 mm, P = .053) and greater maximum internal tibial rotation (-6.2° vs -3.0°, P = .040), supporting a more anterior-based position of the medial condyle. The PCL released group had lower median Knee Injury and Osteoarthritis Outcome Score for Joint Replacement scores (70.7 vs 76.3, P = .031) and reported that their knees "sometimes or always" feel normal less frequently (81.8% vs 92.3%, P = .576). CONCLUSION: With this asymmetric ultracongruent bearing TKA, preservation or partial titration release of the PCL, as opposed to full PCL release, appears to minimize deleterious anterior femoral translation and internal tibial rotation, which is correlated with optimized patient-reported outcomes. LEVEL OF EVIDENCE: II.
引用
- Meneghini RM, Deckard ER, Banks SA, et al. The Effect of Posterior Cruciate Ligament Release on Kinematics and Outcomes in Primary Total Knee Arthroplasty With a Dual-Pivot Conforming Polyethylene. J Arthroplasty. 2022. PMID: 35217184. doi:10.1016/j.arth.2022.02.061
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。