文献速递关节外科

假体设计是否影响外侧单髁膝关节置换术的失败率?一项荟萃分析

Does Implant Design Influence Failure Rate of Lateral Unicompartmental Knee Arthroplasty? A Meta-Analysis.
PubMed 文献 · J Arthroplasty · 2022-02-01

该荟萃分析纳入21项研究,比较固定平台金属底座(FB M-B)、固定平台全聚乙烯(FB A-P)与活动平台金属底座(MB M-B)外侧单髁膝关节置换术的失败率。FB M-B失败率0.8%,显著低于FB A-P的8.6%和MB M-B的7.1%;按随访时间分层比较各组间无显著差异。作者认为FB M-B设计因失败率更低、假体生存期更长而更可取。

要点

  • FB M-B外侧单髁膝关节置换术失败率为0.8%,显著低于FB A-P的8.6%和MB M-B的7.1%。
  • 按随访时间(<5年、5-10年、>10年)比较,各假体设计组间无显著差异。
  • 作者认为,面对外侧单髁膝关节置换术,FB M-B设计因失败率更低、假体生存期更长而更可取。

核心结论

  • 基于现有证据,作者认为对于行外侧单髁膝关节置换术的术者,FB M-B设计更可取,因其失败率更低、假体生存期更长。

研究设计与样本

  • 按照系统评价和荟萃分析首选报告条目(PRISMA)开展系统评价,检索MEDLINE、EMBASE、Cochrane和PubMed 4个数据库,纳入21项研究外侧单髁膝关节置换术结局的研究。
  • 分别按假体类型(FB M-B vs FB A-P vs MB M-B)和随访时间(<5年、5至10年、>10年)进行失败率比较,以评估潜在混杂因素。

主要发现

  • FB M-B外侧单髁膝关节置换术的失败率为0.8%,FB A-P为8.6%,MB M-B为7.1%,FB M-B显著低于其他两种设计。
  • 按随访时间比较所有假体时,各组间未检测到显著差异。

临床怎么用

  • 作者认为,对于行外侧单髁膝关节置换术的术者,FB M-B设计更可取,因其失败率更低、假体生存期更长。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Lateral unicompartmental knee arthroplasty (UKA) is a viable solution for isolated lateral compartment arthritis. Several prosthetic designs are available such as fixed-bearing metal-backed (FB M-B), fixed-bearing all-polyethylene (FB A-P), and mobile-bearing metal-backed (MB M-B) implants. The purpose of this meta-analysis is to compare failure rates of different prosthetic designs. METHODS: Preferred Reporting Items for Systematic Reviews and Meta-Analyses systematic review was conducted using 4 databases (MEDLINE, EMBASE, Cochrane, and PubMed) to identify all studies that investigate outcomes of lateral UKA. Twenty-one studies met the inclusion criteria, and failure rates were compared by implant type and follow-up time separately in order to assess potential confounding factors. Two separate analyses have been performed among different implant designs (FB M-B vs FB A-P vs MB M-B) and different follow-ups (<5 years, between 5 and 10 years, >10 years). RESULTS: The failure rate of FB M-B lateral UKA was significantly lower compared to other lateral UKA designs present in the market (0.8% vs 8.6% and 7.1% for FB M-B, FB A-P, and MB M-B, respectively). No significative difference among groups has been detected when comparing all implants with regard to follow-up time. CONCLUSION: Considering actual evidence, for a surgeon approaching lateral UKA, the FB M-B design is preferable, given the lower failure rates and subsequently a longer implant survivorship.