第一代退火高交联聚乙烯在非骨水泥全髋关节置换术中的耐磨性在术后20年仍得以维持
该回顾性研究评估了29例患者(35髋)在非骨水泥全髋关节置换术中应用第一代退火高交联聚乙烯的性能,平均随访19.1年,19年全因翻修生存率为97.0%(95%CI 91至100),总体稳态磨损率为0.013 mm/年(SD 0.012),无骨溶解或松动,JOA评分从术前43.2改善至末次随访90.2(p < 0.001)。
要点
- 19年全因翻修生存率为97.0%(95%CI 91至100)。
- 总体稳态磨损率为0.013 mm/年(SD 0.012),无髋磨损率>0.1 mm/年。
- JOA评分从术前43.2改善至末次随访90.2(p < 0.001),无骨溶解或松动。
核心结论
- 第一代退火高交联聚乙烯在约20年内表现出优异的耐磨性且磨损未加速,全因翻修率低。
研究设计与样本
- 回顾性评估2000年12月至2002年2月间接受非骨水泥全髋关节置换术的29例患者(35髋)。
- 采用Kaplan-Meier法估计生存率,采用日本骨科协会(JOA)评分评估髋关节功能,采用Martell髋关节分析套件估测二维聚乙烯磨损。
- 计算术后1至5年、5至10年、10至15年及15年至末次随访间的磨损率。
主要发现
- 平均随访19.1年(SD 0.6;17.3至20.1)。
- 19年全因翻修总体生存率为97.0%(95%CI 91至100)。
- 平均JOA评分从术前43.2(SD 10.6;30至76)改善至末次随访90.2(SD 6.4;76至98)(p < 0.001)。
- 无髋臼或股骨组件骨溶解或松动。
- 总体稳态磨损率为0.013 mm/年(SD 0.012),无髋稳态磨损率>0.1 mm/年,各期间磨损率无显著差异,磨损率与年龄、体重、BMI或杯倾角无显著相关性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA). METHODS: We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell's Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up. RESULTS: The mean follow-up period was 19.1 years (SD 0.6; 17.3 to 20.1). The 19-year overall survival rate with the end point of all-cause revision was 97.0% (95% confidence interval (CI) 91 to 100). The mean JOA score improved from 43.2 (SD 10.6; 30 to 76) before surgery to 90.2 (SD 6.4; 76 to 98) at the final follow-up (p < 0.001). There was no osteolysis or loosening of the acetabular or femoral components. The overall steady-state wear rate was 0.013 mm/year (SD 0.012). There was no hip with a steady-state wear rate of > 0.1 mm/year. There was no significant difference in wear rates for each period. We found no significant correlation between the wear rate and age, body weight, BMI, or cup inclination. CONCLUSION: First-generation annealed HXLPE shows excellent wear resistance and no acceleration of wear for approximately 20 years, with low all-cause revision rates. Cite this article: Bone Joint J 2022;104-B(2):200-205.
引用
- Orita K, Goto K, Kuroda Y, et al. Wear resistance of first-generation highly cross-linked annealed polyethylene in cementless total hip arthroplasty is maintained 20 years after surgery. Bone Joint J. 2022. PMID: 35094568. doi:10.1302/0301-620X.104B2.BJJ-2021-1079.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。