文献速递关节外科

初次全膝关节置换术后患者对膝关节活动度「满意度」与客观测量值的相关性

Correlation Between Patient-Reported "Happiness" With Knee Range of Motion and Objective Measurements in Primary Knee Arthroplasty.
PubMed 文献 · J Arthroplasty · 2022-02-21

本研究回顾了2019年6月至12月所有初次全膝关节置换术,共902例患者(1009膝),评估客观膝关节活动度与患者对活动度「满意度」的相关性。术后6周平均活动度106±13度,76%患者对活动度满意,均较术前显著变化;术后不满意者活动度更低、活动度下降更多。作者认为早期术后活动度与患者满意度相关,但需更长期随访和更详细分析。

要点

  • 术前平均活动度110±16度,40%患者对活动度满意;术后6周平均106±13度,76%满意。
  • 术后满意者平均活动度109±12度、变化-2±16度;不满意者98±14度、变化-12±18度。
  • 7.2%膝关节行麻醉下手法松解,其中28%在松解前对活动度满意。

核心结论

  • 早期术后膝关节活动度与患者对活动度的满意度相关,但需更长期随访和对患者满意度更详细的分析。

研究设计与样本

  • 回顾性综述,纳入2019年6月至12月所有初次全膝关节置换术,共902例患者(1009膝),评估术前及术后6周随访时的膝关节活动度及患者自报是否对活动度满意(HWROM)。

主要发现

  • 术前平均活动度110±16度,40%患者对活动度满意;术后6周平均活动度106±13度(P < .001),76%患者对活动度满意(P < .001)。
  • 膝关节活动度平均变化为-5±17度。
  • 术后对活动度满意者平均活动度109±12度、活动度变化-2±16度;术后不满意者平均活动度98±14度、活动度变化-12±18度(P < .001)。
  • 术前活动度较低的患者更可能出现对活动度满意度的正向变化(f比值=41,P < .001)。
  • 7.2%的膝关节行麻醉下手法松解,其中28%的患者在松解前对活动度满意。

局限性

  • 原文指出需要更长期的随访和对患者满意度更详细的分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The purpose of this study was to evaluate the correlation between objective knee range of motion (ROM) and patient "happiness" with knee ROM after total knee arthroplasty. METHODS: This was a retrospective review of all primary total knee arthroplasties from June through December 2019, yielding 902 patients (1,009 knees). Records were reviewed for knee ROM preoperatively and postoperatively at 6-week follow-up as well as whether patients self-reported being "Happy with their ROM" (HWROM). Clinical records were reviewed for documents ROM as well as manipulation under anesthesia (MUA). RESULTS: The mean preoperative ROM was 110 ± 16 degrees, and 40% of patients were happy with their ROM. Postoperatively, the mean ROM was 106 ± 13 degrees (P < .001), and 76% of patients were HWROM (P < .001). The mean change in knee ROM was (-) 5 ± 17 degrees. The mean postoperative ROM and change in ROM of patients who were HWROM after surgery were 109 ± 12 degrees and (-)2 ± 16 degrees. In patients not HWROM postoperatively, the mean ROM and change in ROM were 98 ± 14 degrees and (-)12 ± 18 degrees (P < .001). Patients with a lower preoperative ROM were statistically significantly more likely to have a positive change in their HWROM (f ratio = 41, P < .001). MUAs were performed in 7.2% of knees, and 28% of patients who underwent an MUA were HWROM before MUA. CONCLUSION: Early postoperative knee ROM was correlated with patient HWROM. However, further longer term follow-up and more detailed analysis of patient happiness with ROM are needed.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Stephens JD, Hurst JM, Morris MJ, et al. Correlation Between Patient-Reported "Happiness" With Knee Range of Motion and Objective Measurements in Primary Knee Arthroplasty. J Arthroplasty. 2022. PMID: 35210146. doi:10.1016/j.arth.2022.01.037

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。